Impermeable Thin Al2O3 Overlay for TBC Protection From Sulfate and Vanadate Attack in Gas Turbines Quarterly Report (open access)

Impermeable Thin Al2O3 Overlay for TBC Protection From Sulfate and Vanadate Attack in Gas Turbines Quarterly Report

In order to improve the hot corrosion resistance of yttria-stabilized zirconia (YSZ), an Al{sub 2}O{sub 3} overlay has been deposited on the surface of YSZ by electron-beam physical vapor deposition. Currently, hot corrosion tests were performed on the YSZ coatings with and without Al{sub 2}O{sub 3} overlay in molten salt mixture (Na{sub 2}SO{sub 4} + 0 {approx} 15wt%V{sub 2}O{sub 5}) at 950 C in order to investigate the effect of amount of vanadate on the hot corrosion behaviors. The results showed that the presence of in V{sub 2}O{sub 5} the molten salt exacerbates the degradation of both the monolithic YSZ coating and the composite YSZ/Al{sub 2}O{sub 3} system. The formation of low-melting Na{sub 2}O-V{sub 2}O{sub 5}-Al{sub 2}O{sub 3} liquid phase is responsible for degradation of the Al{sub 2}O{sub 3} overlay. The Al{sub 2}O{sub 3} overlay acts as a barrier against the infiltration of the molten salt into the YSZ coating during exposure to the molten salt mixture with <5wt% vanadate. In the next reporting period, we will use XPS and SIMS to study the interactions between alumina overlay and molten salt containing vanadate.
Date: June 10, 2003
Creator: Mao, Scott X.