241-AN-A pit leak detection ANA-WT-LDSTA-331 acceptance test procedure (open access)

241-AN-A pit leak detection ANA-WT-LDSTA-331 acceptance test procedure

This document describes the method used to test design criteria for Safety Class, Intrinsically Safe leak detector system installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this Procedure is to demonstrate that the pit leak detection relay cabinet and intrinsically safe probe circuit is fully operable.
Date: August 25, 1999
Creator: VANDYKE, D.W.
Object Type: Report
System: The UNT Digital Library
241-AN-A valve pit manifold valves and position indication acceptance test procedure (open access)

241-AN-A valve pit manifold valves and position indication acceptance test procedure

This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.
Date: August 25, 1999
Creator: VANDYKE, D.W.
Object Type: Report
System: The UNT Digital Library
241-AN-B pit leak detection ANA-WT-LDSTA-231 acceptance test procedure (open access)

241-AN-B pit leak detection ANA-WT-LDSTA-231 acceptance test procedure

This document describes the method used to test design criteria for Safety Class, Intrinsically Safe leak detector system installed in 241-AN-B Valve Pit located at 200E Tank Farms. The purpose of this Procedure is to demonstrate that the pit leak detection relay cabinet and intrinsically safe probe circuit is fully operable.
Date: August 25, 1999
Creator: VANDYKE, D.W.
Object Type: Report
System: The UNT Digital Library
241-AN-B valve pit manifold valves and position indication acceptance test procedure (open access)

241-AN-B valve pit manifold valves and position indication acceptance test procedure

This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-B Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-B Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.
Date: August 25, 1999
Creator: VANDYKE, D.W.
Object Type: Report
System: The UNT Digital Library
241-AN Double Shell Tanks (DST) Integrity Assessment Report (open access)

241-AN Double Shell Tanks (DST) Integrity Assessment Report

This report presents the results of the integrity assessment of the 241-AN double-shell tank farm facility located in the 200 East Area of the Hanford Site. The assessment included the design evaluation and integrity examinations of the tanks and concluded that the facility is adequately designed, is compatible with the waste, and is fit for use. Recommendations including subsequent examinations, are made to ensure the continued safe operation of the tanks.
Date: September 21, 1999
Creator: Jensen, C. E.
Object Type: Report
System: The UNT Digital Library
241-AW Double Shell Tanks (DST) Integrity Assessment Report (open access)

241-AW Double Shell Tanks (DST) Integrity Assessment Report

This report presents the results of the integrity assessment of the 241-AW double-shell tank farm facility located in the 200 East Area of the Hanford Site. The assessment included the design evaluation and integrity examinations of the tanks and concluded that the facility is adequately designed, is compatible with the waste, and is fit for use. Recommendations including subsequent examinations, are made to ensure the continued safe operation of the tanks.
Date: September 21, 1999
Creator: Jensen, C. E.
Object Type: Report
System: The UNT Digital Library
241-AY Double Shell Tanks (DST) Integrity Assessment Report (open access)

241-AY Double Shell Tanks (DST) Integrity Assessment Report

This report presents the results of the integrity assessment of the 241-AY double-shell tank farm facility located in the 200 East Area of the Hanford Site. The assessment included the design evaluation and integrity examinations of the tanks and concluded that the facility is adequately designed, is compatible with the waste, and is fit for use. Recommendations including subsequent examinations. are made to ensure the continued safe operation of the tanks.
Date: September 21, 1999
Creator: JENSEN, C.E.
Object Type: Report
System: The UNT Digital Library
241-AZ Double Shell Tanks (DST) Integrity Assessment Report (open access)

241-AZ Double Shell Tanks (DST) Integrity Assessment Report

This report presents the results of the integrity assessment of the 241-A2 double-shell tank farm facility located in the 200 East Area of the Hanford Site. The assessment included the design evaluation and integrity examinations of the tanks and concluded that the facility is adequately designed, is compatible with the waste, and is fit for use. Recommendations including subsequent examinations, are made to ensure the continued safe operation of the tanks.
Date: September 21, 1999
Creator: JENSEN, C.E.
Object Type: Report
System: The UNT Digital Library
241-SY-101 DACS High hydrogen abort limit reduction (SCR 473) acceptance test report (open access)

241-SY-101 DACS High hydrogen abort limit reduction (SCR 473) acceptance test report

The capability of the 241-SY-101 Data Acquisition and Control System (DACS) computer system to provide proper control and monitoring of the 241-SY-101 underground storage tank hydrogen monitoring system utilizing the reduced hydrogen abort limit of 0.69% was systematically evaluated by the performance of ATP HNF-4927. This document reports the results of the ATP.
Date: September 9, 1999
Creator: ERMI, A.M.
Object Type: Report
System: The UNT Digital Library
241-SY-101 DACS instrument problem screen (SCR 448) acceptance test procedure (open access)

241-SY-101 DACS instrument problem screen (SCR 448) acceptance test procedure

The operability of the 241-SY-101 Data Acquisition and Control System (DACS) to provide proper control and monitoring of the mitigation mixer pump and instrumentation installed in the 241-SY-101 underground storage tank utilizing the [INSTPROB] screen will be systematically evaluated by the performance of this procedure.
Date: June 28, 1999
Creator: Ermi, A. M.
Object Type: Report
System: The UNT Digital Library
241-SY-101 data acquisition and control system (DACS) operator interface upgrade operational test report (open access)

241-SY-101 data acquisition and control system (DACS) operator interface upgrade operational test report

This procedure provides instructions for readiness of the first portion of the upgraded 241-SY-101 Data Acquisition and Control System (DACS) computer system to provide proper control and monitoring of the mitigation mixer pump and instrumentation installed in the 241-SY-101 underground storage tank will be systematically evaluated by the performance of this procedure.
Date: May 11, 1999
Creator: Ermi, A. M.
Object Type: Report
System: The UNT Digital Library
241-SY-101 data acquisition and control system (DACS) remote operator interface operational test report (open access)

241-SY-101 data acquisition and control system (DACS) remote operator interface operational test report

The readiness of the upgraded 241-SY-101 Data Acquisition and Control System (DACS) to provide proper control and monitoring of the mixer pump and instrumentation in tank 241-SY-101 was evaluated by the performance of OTP-440-001. Results of the OTP are reported here.
Date: June 24, 1999
Creator: Ermi, A. M>
Object Type: Report
System: The UNT Digital Library
241-SY Double Shell Tanks (DST) Integrity Assessment Report (open access)

241-SY Double Shell Tanks (DST) Integrity Assessment Report

This report presents the results of the integrity assessment of the 241-SY double-shell tank farm facility located in the 200 West Area of the Hanford Site. The assessment included the design evaluation and integrity examinations of the tanks and concluded that the facility is adequately designed, is compatible with the waste, and is fit for use. Recommendations including subsequent examinations, are made to ensure the continued safe operation of the tanks.
Date: September 21, 1999
Creator: JENSEN, C.E.
Object Type: Report
System: The UNT Digital Library
241-Z-361 Sludge Characterization Sampling and Analysis Plan (open access)

241-Z-361 Sludge Characterization Sampling and Analysis Plan

This sampling and analysis plan (SAP) identifies the type, quantity, and quality of data needed to support characterization of the sludge that remains in Tank 241-2-361. The procedures described in this SAP are based on the results of the 241-2-361 Sludge Characterization Data Quality Objectives (DQO) (BWHC 1999) process for the tank. The primary objectives of this project are to evaluate the contents of Tank 241-2-361 in order to resolve safety and safeguards issues and to assess alternatives for sludge removal and disposal.
Date: July 29, 1999
Creator: BANNING, D.L.
Object Type: Report
System: The UNT Digital Library
241-Z-361 Sludge Characterization Sampling and Analysis Plan (open access)

241-Z-361 Sludge Characterization Sampling and Analysis Plan

This sampling and analysis plan (SAP) identifies the type, quantity, and quality of data needed to support characterization of the sludge that remains in Tank 241-2-361. The procedures described in this SAP are based on the results of the 241-2-361 Sludge Characterization Data Quality Objectives (DQO) (BWHC 1999) process for the tank. The primary objectives of this project are to evaluate the contents of Tank 241-2-361 in order to resolve safety and safeguards issues and to assess alternatives for sludge removal and disposal.
Date: August 5, 1999
Creator: BANNING, D.L.
Object Type: Report
System: The UNT Digital Library
242-A Campaign 99-1 process control plan (open access)

242-A Campaign 99-1 process control plan

242-A Evaporator 99-1 will process approximately one million gallons of waste from tank 102-AW in June 1999. The process control Plan provides a general description of activities, which will occur during 242-A Evaporator Campaign 99-1 and to document analyses conducted to demonstrate that 102-AW waste is acceptable for processing. Predict is a registered trademark of Risk Decisions England Corporation, United Kingdom.
Date: August 25, 1999
Creator: Le, E. Q.
Object Type: Report
System: The UNT Digital Library
242-A evaporator safety analysis report (open access)

242-A evaporator safety analysis report

This report provides a revised safety analysis for the upgraded 242-A Evaporator (the Evaporator). This safety analysis report (SAR) supports the operation of the Evaporator following life extension upgrades and other facility and operations upgrades (e.g., Project B-534) that were undertaken to enhance the capabilities of the Evaporator. The Evaporator has been classified as a moderate-hazard facility (Johnson 1990). The information contained in this SAR is based on information provided by 242-A Evaporator Operations, Westinghouse Hanford Company, site maintenance and operations contractor from June 1987 to October 1996, and the existing operating contractor, Waste Management Hanford (WMH) policies. Where appropriate, a discussion address the US Department of Energy (DOE) Orders applicable to a topic is provided. Operation of the facility will be compared to the operating contractor procedures using appropriate audits and appraisals. The following subsections provide introductory and background information, including a general description of the Evaporator facility and process, a description of the scope of this SAR revision,a nd a description of the basic changes made to the original SAR.
Date: May 17, 1999
Creator: CAMPBELL, T.A.
Object Type: Report
System: The UNT Digital Library
242-A MCS Logic Acceptance Test Report for Year 2000 Upgrade (open access)

242-A MCS Logic Acceptance Test Report for Year 2000 Upgrade

242-A Evaporator distributive control system upgrade to D/3 version 9.0-2 for year 2000 compliance. Testing was performed per test procedure HNF-3568. There were no unresolved exceptions. The system responded correctly to all testing and meets the requirements to operate the 242-A This report documents the acceptance test results for the Evaporator facility.
Date: August 31, 1999
Creator: Teats, M. C.
Object Type: Report
System: The UNT Digital Library
300 Area Disturbance Report (open access)

300 Area Disturbance Report

The objective of this study was to define areas of previous disturbance in the 300 Area of the U.S. Department of Energy (DOE) Hanford Site to eliminate these areas from the cultural resource review process, reduce cultural resource monitoring costs, and allow cultural resource specialists to focus on areas where subsurface disturbance is minimal or nonexistent. Research into available sources suggests that impacts from excavations have been significant wherever the following construction activities have occurred: building basements and pits, waste ponds, burial grounds, trenches, installation of subsurface pipelines, power poles, water hydrants, and well construction. Beyond the areas just mentioned, substrates in the' 300 Area consist of a complex, multidimen- sional mosaic composed of undisturbed stratigraphy, backfill, and disturbed sediments; Four Geographic Information System (GIS) maps were created to display known areas of disturbance in the 300 Area. These maps contain information gleaned from a variety of sources, but the primary sources include the Hanford GIS database system, engineer drawings, and historic maps. In addition to these maps, several assumptions can be made about areas of disturbance in the 300 Area as a result of this study: o o Buried pipelines are not always located where they are mapped. As …
Date: January 7, 1999
Creator: Hale, L. L.; Wright, M. K. & Cadoret, N. A.
Object Type: Report
System: The UNT Digital Library
300 Area Treated Effluent Disposal Facility (TEDF) Hazards Assessment (open access)

300 Area Treated Effluent Disposal Facility (TEDF) Hazards Assessment

This document establishes the technical basis in support of emergency planning activities for the 300 Area Treated Effluent Disposal Facility. The technical basis for project-specific Emergency Action Levels and Emergency Planning Zone is demonstrated.
Date: January 15, 1999
Creator: CAMPBELL, L.R.
Object Type: Report
System: The UNT Digital Library
300 Area waste acid treatment system closure plan (open access)

300 Area waste acid treatment system closure plan

The Hanford Facility Dangerous Waste Permit Application is considered to be a single application organized into a General Information Portion (document number DOERL-91-28) and a Unit-Specific Portion. The scope of the Unit-Specific Portion includes closure plan documentation submitted for individual, treatment, storage, and/or disposal units undergoing closure, such as the 300 Area Waste Acid Treatment System. Documentation contained in the General Information Portion is broader in nature and could be used by multiple treatment, storage, and/or disposal units (e.g., the glossary provided in the General Information Portion). Whenever appropriate, 300 Area Waste Acid Treatment System documentation makes cross-reference to the General Information Portion, rather than duplicating text. This 300 Area Waste Acid Treatment System Closure Plan (Revision 2) includes a Hanford Facility Dangerous Waste Permit Application, Part A, Form 3. Information provided in this closure plan is current as of April 1999.
Date: May 17, 1999
Creator: LUKE, S.N.
Object Type: Report
System: The UNT Digital Library
324 and 327 Facilities Environmental Effluent Specifications (open access)

324 and 327 Facilities Environmental Effluent Specifications

These effluent specifications address requirements for the 324/321 Facilities, which are undergoing stabilization activities. Effluent specifications are imposed to protect personnel, the environment and the public, by ensuring adequate implementation and compliance with federal and state regulatory requirements and Hanford programs.
Date: August 30, 1999
Creator: Johnson, D. L.
Object Type: Report
System: The UNT Digital Library
324 Bldg Liquid Waste Handling System Functional Design Criteria (open access)

324 Bldg Liquid Waste Handling System Functional Design Criteria

The 324 Building in the 300 Area of the Hanford Site, is preparing to design, construct, and operate the Liquid Waste Handling System (LWHS). The system will include transfer, collection, treatment, and disposal of radiological and mixed liquid waste.
Date: December 16, 1999
Creator: Ham, J. E.
Object Type: Report
System: The UNT Digital Library
324 Building fire hazards analysis implementation plan (open access)

324 Building fire hazards analysis implementation plan

In March 1998, the 324 Building Fire Hazards Analysis (FHA) (Reference 1) was approved by the U S. Department of Energy, Richland Operations Office (DOE-RL) for implementation by B and W Hanford Company (BWHC). The purpose of the FHA was to identify gaps in compliance with DOE Order 5480.7A (Reference 2) and Richland Operations Office Implementation Directive (RLID) 5480.7 (Reference 3), especially in regard to loss limitation. The FHA identified compliance gaps in six areas and provided 20 recommendations to bring the 324 Building into compliance with DOE Order 5480 7A. Additionally, one observation was provided. A status is provided for each recommendation in this document. The actions for recommendations associated with the safety related part of the 324 Building and operation of the cells and support areas were evaluated using the Unreviewed Safety Question (USQ) process BWHC will use this Implementation Plan to bring the 324 Building and its operation into compliance with DOE Order 5480 7A and RLID 5480.7.
Date: May 10, 1999
Creator: Barilo, N. F.
Object Type: Report
System: The UNT Digital Library