9 Matching Results

Results open in a new window/tab.

Atom transfer and rearrangement reactions catalyzed by methyltrioxorhenium, MTO (open access)

Atom transfer and rearrangement reactions catalyzed by methyltrioxorhenium, MTO

Methyltrioxorhenium (MTO) catalyzes the desulfurization of thiiranes by triphenylphosphine. Enormous enhancement in rate is observed when the catalyst is pretreated with hydrogen sulfide prior to the reaction. Using 2-mercaptomethylthiophenol as a ligand, the author synthesized several model complexes to study the mechanism of this reaction. With suitable model systems, they were able to show that the active catalyst is a Re(V) species. The reactions are highly stereospecific and very tolerant to functional groups. As part of the studies, he synthesized and crystallographically characterized the first examples of neutral terminal and bridging Re(V)sulfidocomplexes. Some of these complexes undergo fast oxygen atom transfer reactions with organic and inorganic oxidants. Studies on these model complexes led them to the discovery that MTO catalyzes the selective oxidation of thiols to disulfides. This report contains the Introduction; ``Chapter 6: Isomerization of Propargylic Alcohols to Enones and Enals Catalyzed by Methylrhenium Trioxide``; and Conclusions.
Date: May 10, 1999
Creator: Jacob, J.
System: The UNT Digital Library
Characterization of electrical resistivity as a function of temperature in the Mo-Si-B system (open access)

Characterization of electrical resistivity as a function of temperature in the Mo-Si-B system

Measurements of electrical resistivity as a function of temperature from 25 to 1,500 C were conducted on polycrystalline samples in the Mo-Si-B system. Single phase, or nearly single phase, samples were prepared for the following phases: Mo{sub 3}Si, Mo{sub 5}SiB{sub 2}, Mo{sub 5}Si{sub 3}B{sub x}, MoB, MoSi{sub 2}, and Mo{sub 5}Si{sub 3}. Thesis materials all exhibit resistivity values within a narrow range(4--22 x 10{sup {minus}7}{Omega}-m), and the low magnitude suggests these materials are semi-metals or low density of states metals. With the exception of MoSi{sub 2}, all single phase materials in this study were also found to have low temperature coefficient of resistivity(TCR) values. These values ranged from 2.10 x 10{sup {minus}10} to 4.74 x 10{sup {minus}10}{Omega}-m/{degree} C, and MoSi{sub 2} had a TCR of 13.77 x 10{sup {minus}10}{Omega}-m/{degree} C. The results from the single phase sample measurements were employed in a natural log rule-of-mixtures model to relate the individual phase resistivity values to those of multiphase composites. Three Mo-Si-B phase regions were analyzed: the binary Mo{sub 5}Si{sub 3}-MoSi{sub 2} system, the ternary phase field Mo{sub 5}Si{sub 3}B{sub x}MoB-MoSi{sub 2}, and the Mo{sub 3}Si-Mo{sub 5}SiB{sub 2}-Mo{sub 5} Si{sub 3}B{sub x} ternary region. The experimental data for samples in each of …
Date: December 10, 1999
Creator: Beckman, Sarah E.
System: The UNT Digital Library
Development and evaluation of high resolution quadrupole mass analyzer and an inductively coupled plasma-Mach disk (open access)

Development and evaluation of high resolution quadrupole mass analyzer and an inductively coupled plasma-Mach disk

By definition a plasma is an electrically conducting gaseous mixture containing a significant concentration of cations and electrons. The Inductively Coupled Plasma (ICP) is an electrodeless discharge in a gas at atmospheric pressure. This discharge is an excellent one for vaporizing, atomizing, and ionizing elements. The early development of the ICP began in 1942 by Babat and then by Reed in the early 1960s. This was then followed by the pioneering work of Fassel and coworkers in the late 1960s. Commercial ICP spectrometers were introduced in the mid 1970s. A major breakthrough in the area of ICP took place in the early 1980s when the ICP was shown to be an excellent ion source for mass spectrometry.
Date: December 10, 1999
Creator: Amad, Ma'an Hazem
System: The UNT Digital Library
Electrochemical and scanning probe microscopic characterization of spontaneously adsorbed organothiolate monolayers at gold (open access)

Electrochemical and scanning probe microscopic characterization of spontaneously adsorbed organothiolate monolayers at gold

This dissertation presented several results which add to the general knowledge base regarding organothiolates monolayer spontaneously adsorbed at gold films. Common to the body of this work is the use of voltammetric reductive resorption and variants of scanning probe microscopy to gain insight into the nature of the monolayer formation process as well as the resulting interface. The most significant result from this work is the success of using friction force microscopy to discriminate the end group orientation of monolayer chemisorbed at smooth gold surfaces with micrometer resolution (Chapter 4). The ability to detect the differences in the orientational disposition is demonstrated by the use PDMS polymer stamp to microcontact print an adlayer of n-alkanethiolate of length n in a predefine pattern onto a gold surface, followed by the solution deposition of a n-alkanethiol of n {+-} 1 to fill in the areas on the gold surface intentionally not coated by the stamping process. These two-component monolayers can be discriminated by using friction force microscopy which detects differences in friction contributed by the differences in the orientation of the terminal groups at surfaces. This success has recently led to the detection of the orientation differences at nanometer scale. Although the …
Date: December 10, 1999
Creator: Wong, Sze-Shun Season
System: The UNT Digital Library
Fast methods for analysis of neurotransmitters from single cell and monitoring their releases in central nervous system by capillary electrophoresis, fluorescence microscopy and luminescence imaging (open access)

Fast methods for analysis of neurotransmitters from single cell and monitoring their releases in central nervous system by capillary electrophoresis, fluorescence microscopy and luminescence imaging

Fast methods for separation and detection of important neurotransmitters and the releases in central nervous system (CNS) were developed. Enzyme based immunoassay combined with capillary electrophoresis was used to analyze the contents of amino acid neurotransmitters from single neuron cells. The release of amino acid neurotransmitters from neuron cultures was monitored by laser induced fluorescence imaging method. The release and signal transduction of adenosine triphosphate (ATP) in CNS was studied with sensitive luminescence imaging method. A new dual-enzyme on-column reaction method combined with capillary electrophoresis has been developed for determining the glutamate content in single cells. Detection was based on monitoring the laser-induced fluorescence of the reaction product NADH, and the measured fluorescence intensity was related to the concentration of glutamate in each cell. The detection limit of glutamate is down to 10{sup {minus}8} M level, which is 1 order of magnitude lower than the previously reported detection limit based on similar detection methods. The mass detection limit of a few attomoles is far superior to that of any other reports. Selectivity for glutamate is excellent over most of amino acids. The glutamate content in single human erythrocyte and baby rat brain neurons were determined with this method and results …
Date: December 10, 1999
Creator: Wang, Ziqiang
System: The UNT Digital Library
In situ vibrational spectroscopic investigation of C{sub 4} hydrocarbon selective oxidation over vanadium-phosphorus-oxide catalysts (open access)

In situ vibrational spectroscopic investigation of C{sub 4} hydrocarbon selective oxidation over vanadium-phosphorus-oxide catalysts

n-Butane selective oxidation over the VPO catalyst to maleic anhydride is the first and only commercialized process of light alkane selective oxidation. The mechanism of this reaction is still not well known despite over twenty years of extensive studies, which can partially be attributed to the extreme difficulties to characterize catalytic reactions real-time under typical reaction conditions. In situ spectroscopic characterization techniques such as Infrared spectroscopy and laser Raman spectroscopy were used in the current mechanistic investigations of n-butane oxidation over VPO catalysts. To identify the reaction intermediates, oxidation of n-butane, 1,3-butadiene and related oxygenates on the VPO catalyst were monitored using FTIR spectroscopy under transient conditions. n-Butane was found to adsorb on the VPO catalyst to form olefinic species, which were further oxidized to unsaturated, noncyclic carbonyl species. The open chain dicarbonyl species then experienced cycloaddition to form maleic anhydride. VPO catalyst phase transformations were investigated using in situ laser Raman spectroscopy. This report contains Chapter 1: General introduction; Chapter 2: Literature review; and Chapter 5: Conclusion and recommendations.
Date: May 10, 1999
Creator: Xue, Z.Y.
System: The UNT Digital Library
Inductively coupled plasma mass spectrometry for stable isotope metabolic tracer studies of living systems (open access)

Inductively coupled plasma mass spectrometry for stable isotope metabolic tracer studies of living systems

This dissertation focuses on the development of methods for stable isotope metabolic tracer studies in living systems using inductively coupled plasma single and dual quadrupole mass spectrometers. Sub-nanogram per gram levels of molybdenum (Mo) from human blood plasma are isolated by the use of anion exchange alumina microcolumns. Million-fold more concentrated spectral and matrix interferences such as sodium, chloride, sulfate, phosphate, etc. in the blood constituents are removed from the analyte. The recovery of Mo from the alumina column is 82 {+-} 5% (n = 5). Isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) is utilized for the quantitative ultra-trace concentration determination of Mo in bovine and human blood samples. The average Mo concentration in reference bovine serum determined by this method is 10.2 {+-} 0.4 ng/g, while the certified value is 11.5 {+-} 1.1 ng/g (95% confidence interval). The Mo concentration of one pool of human blood plasma from two healthy male donors is 0.5 {+-} 0.1 ng/g. The inductively coupled plasma twin quadrupole mass spectrometer (ICP-TQMS) is used to measure the carbon isotope ratio from non-volatile organic compounds and bio-organic molecules to assess the ability as an alternative analytical method to gas chromatography combustion isotope ratio mass spectrometry …
Date: May 10, 1999
Creator: Luong, E.
System: The UNT Digital Library
Liquid metal extraction of Nd from NdFeB magnet scrap (open access)

Liquid metal extraction of Nd from NdFeB magnet scrap

This research involves using molten magnesium (Mg) to remove neodymium (Nd) from NdFeB magnet scrap by diffusion. The results show that liquid metal extraction of Nd may be a viable and inexpensive method for recovering the expensive rare earth element Nd for use in Mg castings.
Date: December 10, 1999
Creator: Xu, Yanchen
System: The UNT Digital Library
Wave propagation in ordered, disordered, and nonlinear photonic band gap materials (open access)

Wave propagation in ordered, disordered, and nonlinear photonic band gap materials

Photonic band gap materials are artificial dielectric structures that give the promise of molding and controlling the flow of optical light the same way semiconductors mold and control the electric current flow. In this dissertation the author studied two areas of photonic band gap materials. The first area is focused on the properties of one-dimensional PBG materials doped with Kerr-type nonlinear material, while, the second area is focused on the mechanisms responsible for the gap formation as well as other properties of two-dimensional PBG materials. He first studied, in Chapter 2, the general adequacy of an approximate structure model in which the nonlinearity is assumed to be concentrated in equally-spaced very thin layers, or 6-functions, while the rest of the space is linear. This model had been used before, but its range of validity and the physical reasons for its limitations were not quite clear yet. He performed an extensive examination of many aspects of the model's nonlinear response and comparison against more realistic models with finite-width nonlinear layers, and found that the d-function model is quite adequate, capturing the essential features in the transmission characteristics. The author found one exception, coming from the deficiency of processing a rigid bottom …
Date: December 10, 1999
Creator: Lidorikis, Elefterios
System: The UNT Digital Library