Experimental study of coupling impedance: Part I longitudinal impedance measurement techniques (open access)

Experimental study of coupling impedance: Part I longitudinal impedance measurement techniques

Beam coupling impedances for the 7-GeV APS storage ring have been numerically estimated. In order to confirm these calculations, measurements of the coupling impedance of various vacuum components around the main storage ring were done with a coaxial wire method. In this paper, the procedure of the longitudinal impedance measurement techniques will be described. As an example, sections of the Cu beam chamber, the Cu beam + antechambers, and the Al beam + antechambers were used as a device under test (DUT) to obtain the results. The transverse impedance measurements will be described in a separate paper.
Date: October 22, 1991
Creator: Song, J.J.
System: The UNT Digital Library
Fusion reactor design studies (open access)

Fusion reactor design studies

This progress report will give a detailed breakdown of the work accomplished for ARIES-III during the contract period, November 1, 1990 to October 31, 1991. The areas of effort discussed are: Neutronics; First-Wall; Shield; Safety; Systems; Startup and Shutdown; Energy Conversion; Ripple Loss; and Fuel Resources.
Date: October 22, 1991
Creator: Santarius, J. F.; Kulcinski, G. L. & Emmert, G. A.
System: The UNT Digital Library
Remediating biofouling of reverse osmosis membranes (open access)

Remediating biofouling of reverse osmosis membranes

Several potential additives and the use of influent pH adjustment were examined to remediated the biofouling problem of the ETF reverse osmosis (RO) system. Tests were conducted with simulated RO feed containing salt, metal hydroxides and bacteria. The addition of sodium hexametaphosphate (SHMP), sodium bisulfite, and adjusting the influent pH to 3 were each successful in reducing the RO biofouling. Little or no benefit was found from the use of a biofilm remover (Filmtec Alkaline Cleaner) or the use of surfactants (Surfynol or sodium lauryl sulfate). In addition, Surfynol use resulted in irreversible fouling and necessitated membrane replacement. At the water recoveries used in the ETF (>90%), sodium bisulfite addition resulted in the recovery of 70--90% of the flux and almost complete restoration of the DF to prefouled conditions. Based on the bench-scale tests completed, IWT would recommend that sodium bisulfite addition be tested at the ETF. This testing would involve optimizing the amount of bisulfite required. In addition, it is recommended that the addition of SHMP or influent pH adjustment be evaluated since the relative differences in labscale tests were small and scale-up effects could be present. The ETF operating permit allows each to be added.
Date: October 22, 1991
Creator: Siler, J. L.
System: The UNT Digital Library
Remediating biofouling of reverse osmosis membranes (open access)

Remediating biofouling of reverse osmosis membranes

Several potential additives and the use of influent pH adjustment were examined to remediated the biofouling problem of the ETF reverse osmosis (RO) system. Tests were conducted with simulated RO feed containing salt, metal hydroxides and bacteria. The addition of sodium hexametaphosphate (SHMP), sodium bisulfite, and adjusting the influent pH to 3 were each successful in reducing the RO biofouling. Little or no benefit was found from the use of a biofilm remover (Filmtec Alkaline Cleaner) or the use of surfactants (Surfynol or sodium lauryl sulfate). In addition, Surfynol use resulted in irreversible fouling and necessitated membrane replacement. At the water recoveries used in the ETF (>90%), sodium bisulfite addition resulted in the recovery of 70--90% of the flux and almost complete restoration of the DF to prefouled conditions. Based on the bench-scale tests completed, IWT would recommend that sodium bisulfite addition be tested at the ETF. This testing would involve optimizing the amount of bisulfite required. In addition, it is recommended that the addition of SHMP or influent pH adjustment be evaluated since the relative differences in labscale tests were small and scale-up effects could be present. The ETF operating permit allows each to be added.
Date: October 22, 1991
Creator: Siler, J. L.
System: The UNT Digital Library
Reverse osmosis performance with solutions containing tri-n-butyl phosphate (open access)

Reverse osmosis performance with solutions containing tri-n-butyl phosphate

Tests were conducted to determine whether the reverse osmosis (RO) units at the F/H Effluent Treatment Facility (ETF) at the Savannah River could be made to process solutions containing tri-n-butyl phosphate (TBP). It was desired to test whether operation at a feed pH other than neutral would improve performance. Test results are discussed in this report and indicate that little improvement in the water flux can be expected at other pH values.
Date: October 22, 1991
Creator: Siler, J. L.
System: The UNT Digital Library
Reverse osmosis performance with solutions containing tri-n-butyl phosphate (open access)

Reverse osmosis performance with solutions containing tri-n-butyl phosphate

Tests were conducted to determine whether the reverse osmosis (RO) units at the F/H Effluent Treatment Facility (ETF) at the Savannah River could be made to process solutions containing tri-n-butyl phosphate (TBP). It was desired to test whether operation at a feed pH other than neutral would improve performance. Test results are discussed in this report and indicate that little improvement in the water flux can be expected at other pH values.
Date: October 22, 1991
Creator: Siler, J.L.
System: The UNT Digital Library