Optical Time-Domain Reflectometer Performance and Calibration Studies (open access)

Optical Time-Domain Reflectometer Performance and Calibration Studies

from Introduction: The measurement accuracy of the optical time-domain reflectometer (OTDR) is restricted in some applications by a limited operational dynamic range and by a lack of standardized test procedures. In an effort to better understand these restrictions, we have measured the range of linearity of some avalanche photodiodes used as backscatter detectors. Also, the effect of input launch conditions is examined and a possible standardized OTDR test procedure is proposed. Using these suggestions, we have made comparisons between attenuation values determined by cutback and backscatter methods and found that good agreement is possible. Finally, some methods are described for checking the response. linearity of OTDR systems.
Date: June 1983
Creator: Danielson, B. L.