300-Area accident analysis for Emergency Planning Zones (open access)

300-Area accident analysis for Emergency Planning Zones

The Department of Energy has requested SRL assistance in developing offsite Emergency Planning Zones (EPZs) for the Savannah River Plant, based on projected dose consequences of atmospheric releases of radioactivity from potential credible accidents in the SRP operating areas. This memorandum presents the assessment of the offsite doses via the plume exposure pathway from the 300-Area potential accidents. 8 refs., 3 tabs.
Date: June 27, 1983
Creator: Pillinger, W.L.
System: The UNT Digital Library
Design requirement for dual air supplies to melter borescope (open access)

Design requirement for dual air supplies to melter borescope

The long term survivability and usefulness of the melter surface viewing borescopes would be greatly increased if a method of remote lense cleaning was available. The two units to be installed on the DWPF melter will incorporate air cooling and lense purging into their design. At present a single air supply line would serve both needs. Separating the two air services will allow the introduction of water or steam into the purge service. Tests on the prototype borescope at ETF have shown this to be an extremely effective way of cleaning the lense of occasional deposits or splatter. It is recommended that this change be incorporated into the DWPF design.
Date: June 27, 1983
Creator: Heckendorn, F.M.
System: The UNT Digital Library
Development of soft x-ray streak cameras at Lawrence Livermore National Laboratory (open access)

Development of soft x-ray streak cameras at Lawrence Livermore National Laboratory

Soft x-ray streak cameras are used in conjunction with several instruments for the diagnostic of laser irradiated targets. A program was undertaken to develop cameras satisfying the requirements of the laser facility, to improve the reliability and performance of the camera and to reduce the level of effort required to set and operate each diagnostic. The implemented soft x-ray streak cameras can be operated either manually or automatically.
Date: June 27, 1983
Creator: Medecki, Hector; Phillips, Glen E. & Bushman, John F.
System: The UNT Digital Library
Measurements of the emittance and current density profile of the beam produced by the ATA injector (open access)

Measurements of the emittance and current density profile of the beam produced by the ATA injector

Measurements of the normalized emittance of the beam produced by the Advanced Test Accelerator (ATA) injector yielded values near 0.4 Radian-Centimeters at currents up to 10 kAmps. The instrument was also used to obtain beam-current-density profiles in two dimensions at the entrance mask of the instrument.
Date: June 27, 1983
Creator: Fessenden, T.J.
System: The UNT Digital Library