Resource Type

3 Matching Results

Results open in a new window/tab.

Active readout KAP x-ray spectrometer. [Laser-produced plasma diagnostics] (open access)

Active readout KAP x-ray spectrometer. [Laser-produced plasma diagnostics]

It was found that a new type of solid-state detector known as the self-scanning photodiode array can be used to obtain the active readout of data in wavelength-dispersive x-ray spectrometers. The use of this device to recover x-ray spectral data for glass microspheres heated by Lawrence Livermore Laboratory's CYCLOPS laser is reported. The self-scanning photodiode array is a product of the MOS electronics fabrication technology. It consists of an array of semi-discrete diffused junction photodiodes deployed along a line on a silicon chip. The signals generated in the array of diodes are serially-scanned and multiplexed by a scanning circuit built on the chip. The sensitivity and other aspects of the response of the photodiode arrays to low-energy x-rays has been previously reported. The photodiode array was used in conjunction with a flat KAP single-crystal in a series of spectrometry experiments. Of particular interest has been the analysis of the hydrogen-like and helium-like 1s-2p radiations of silicon in the neighborhood of 2 keV.
Date: October 6, 1975
Creator: Koppel, L. N.; Richards, L. M. & Campbell, D. E.
System: The UNT Digital Library
Spectral measurements of x-rays and electrons emitted from 1. 06. mu. m laser produced plasmas (open access)

Spectral measurements of x-rays and electrons emitted from 1. 06. mu. m laser produced plasmas

Absolute spectral measurements were made of electrons escaping from plasmas produced by focusing 5-10 J, 50-100 picosecond, 1.06 ..mu..m laser pulses on 10 ..mu..m thick Parylene disk targets. Nine spectral bands with 3 to 7.5 keV resolution were obtained from 30 to 190 keV using a 90/sup 0/ focusing permanent magnet spectrometer and appropriately positioned silicon electron detectors.
Date: October 6, 1975
Creator: Tirsell, K. G.; Kornblum, H. N.; Catron, H. C. & Slivinsky, V. W.
System: The UNT Digital Library
X-ray line spectra from DT filled SiO/sub 2/ microshells (open access)

X-ray line spectra from DT filled SiO/sub 2/ microshells

This paper is a discussion of curved crystal x-ray spectrometry of laser induced plasmas for h..nu.. < 4 keV. The plasmas were produced by a short pulse (<200 ps) of 1.06 ..mu.. (neodymium glass) radiation on glass shells on the order of a hundred ..mu..m in diameter and a micron thick. Total absorbed laser energy is of the order of 10 joules and x-radiation .01-.1 joule/sr. The shells were filled with DT gas under compression.
Date: October 6, 1975
Creator: Richards, L. & Eckels, D.
System: The UNT Digital Library