Resource Type

1,314 Matching Results

Results open in a new window/tab.

1.1-meter bore, 8-Tesla test facility (open access)

1.1-meter bore, 8-Tesla test facility

The design and fabrication of a 1.1-m bore superconducting coil for an 8- T facility at Lawrence Livermore Laboratory are discussed. This facility will provide the backing field required for testing large multifilamentary Nb$sub 3$Sn coils as part of the superconductor development program at Livermore. The magnet measures 1.85 m o.d., is 1.5 m in length, and is solenoid wound in four separate modules. Total cold weight of the assembly is 18,000 Kg. A NbTi superconductor is used throughout with a gradation of current density within the magnet to provide complete cryostatic stability. The preliminary design of a large 3500-A multifilamentary Nb$sub 3$Sn insert magnet is also included. Together, the backing coil and insert magnets are designed to produce a 12-T central field in a 0.4m bore. The ''equal area'' theory of cryostatic stability is applied in the design of both magnet systems and is discussed in detail. A large open-mouth cryostat is used and measures 2 m in diameter and 3.7 m in length. Details of Dewar design and the refrigeration requirements are included. (auth)
Date: November 19, 1975
Creator: Nelson, R.; Cornish, D.; Zbasnik, J.; Sackett, S. & Taylor, C.
System: The UNT Digital Library
1.06 μm 150 psec laser damage study of diamond turned, diamond turned/ polished and polished metal mirrors (open access)

1.06 μm 150 psec laser damage study of diamond turned, diamond turned/ polished and polished metal mirrors

Using a well characterized 1.06 μm 150 ps glass laser pulse the damage characteristics for diamond turned, diamond turned/ polished, and polished copper and silver mirrors less than 5 cm diameter were studied. Although most samples were tested with a normal angle of incidence, some were tested at 45$sup 0$ with different linear polarization showing an increase in damage threshold for S polarization. Different damage mechanisms observed will be discussed. Laser damage is related to residual surface influences of the fabrication process. First attempts to polish diamond turned surfaces resulted in a significant decrease in laser damage threshold. The importance of including the heat of fusion in the one dimensional heat analysis of the theoretical damage threshold and how close the samples came to the theoretical damage threshold is discussed. (auth)
Date: July 24, 1975
Creator: Saito, T. T.; Milam, D.; Baker, P. & Murphy, G.
System: The UNT Digital Library
15-foot bubble chamber characteristics (open access)

15-foot bubble chamber characteristics

Specifications, operation, characteristics, cost, and experience with the NAL 15-ft bubble chamber are described. Beam availability and some experimental proposals are discussed. (WHK)
Date: September 15, 1975
Creator: Huson, F. R.
System: The UNT Digital Library
15 MeV neutron damage in Cu and Nb (open access)

15 MeV neutron damage in Cu and Nb

An investigation was made of high-energy neutron damage in Cu and Nb irradiated with approximately 15 MeV neutrons at the Oak Ridge Isochronous Cyclotron. The neutrons were generated by bombarding a thick Be target with 40- MeV deuterons resulting in a high energy neutron spectrum broadly peaked at 15 MeV. Single crystals of Cu and Nb were irradiated at room temperature to fluences of approximately 2 x 10$sup 17$ n/cm$sup 2$. The resulting loop-type defect clusters in the crystals were characterized using x-ray diffuse scattering and transmission electron microscopy. The cluster size distributions were found to be generally similar to those characteristic of fission neutron irradiations in these materials and no multiple clusters or sub-clusters were observed. Additional comparisons with fission reactor irradiations in Cu and Nb indicate that the retained displacement damage in these crystals is approximately 3 times greater for the high-energy neutrons than for an equivalent fluence of fission neutrons. This result is consistent with detailed damage energy calculations for the Be(d,n) neutron spectrum. (auth)
Date: January 1, 1975
Creator: Roberto, J. B.; Narayan, J. & Saltmarsh, M. J.
System: The UNT Digital Library
19 mm ballistic range: a potpourri of techniques and recipes (open access)

19 mm ballistic range: a potpourri of techniques and recipes

The expansion of ballistic gun range facilities at LLL has introduced state-of-the-art diagnostic techniques to glovebox-enclosed ballistic guns systems. These enclosed ballistic ranges are designed for the study of one- dimensional shock phenomena in extremely toxic material such as plutonium. The extension of state-of-the-art phtographic and interferometric diagnostic systems to glovebox-enclosed gun systems introduces new design boundaries and performance criteria on optical and mechanical components. A technique for experimentally evaluating design proposals is illustrated, and several specific examples (such as, target alignment, collateral shrapnel damage, and soft recovery) are discussed. (auth)
Date: September 23, 1975
Creator: Carpluk, G.T.
System: The UNT Digital Library
100 mg $sup 251$Cf activation analysis facility at the Savannah River Laboratory (open access)

100 mg $sup 251$Cf activation analysis facility at the Savannah River Laboratory

The $sup 252$Cf Activation Analysis Facility at the Savannah River Laboratory (SRL) is used routinely for multielement analyses of a wide variety of solid and liquid samples (e.g., metal alloys, fly ash and other airborne particles, rocks, and aqueous and nonaqueous solutions). An automated absolute activation analysis technique, developed to use neutron transport codes to calculate multienergy group neutron spectra and fluxes, converts counting data directly into elemental concentrations expressed in parts per million. The facility contains four sources of $sup 252$Cf totaling slightly over 100 mg. A pneumatic ''rabbit'' system permits automatic irradiation/decay/counting regimes to be performed unattended on up to 100 samples. Detection sensitivities of less than or equal to 400 ppb natural uranium and less than or equal to 0.5 nCi/g for $sup 239$Pu are observed. Detection limits for over 65 elements have been determined. Over 40 elements are detectable at the one part per million level or less. Overall accuracies of +- 10 percent are observed for most elements. (auth)
Date: January 1, 1975
Creator: MacMurdo, K. W. & Bowman, W. W.
System: The UNT Digital Library
120 kA pulsed dc power system with computerized thyristor triggering (open access)

120 kA pulsed dc power system with computerized thyristor triggering

A pulsed dc power system provides 120 kA excitation current for the ORMAK toroidal field coils. A drive potential of 1000 volts brings the coils up to full current in about 0.5 seconds. Constant current is maintained for 0.25 seconds, then approximately 20 x 10$sup 6$ joules of stored energy is dumped in a free-wheeling diode and resistance network. The power system contains 8 each, 30 kA, 500 V thyristor controlled dc power modules in a series/parallel combination. A control computer generates thyristor trigger pulses in a programmed sequence as required for the desired duty cycle. A feedback network including current sensing and computer software permits trigger timing adjustments as necessary for constant current operation. (auth)
Date: January 1, 1975
Creator: Mosko, S. W.; Bates, D. D.; Bigelow, R. R.; Cottongim, E. K.; Pipes, E. W. & Sueker, K.
System: The UNT Digital Library
150 MeV proton medical cyclotron design study (open access)

150 MeV proton medical cyclotron design study

None
Date: August 1975
Creator: Burleigh, R. J.; Clark, D. J. & Flood, W. S.
System: The UNT Digital Library
200 kW, 800 MHz transmitter system for lower hybrid heating (open access)

200 kW, 800 MHz transmitter system for lower hybrid heating

This paper describes a new rf heating system which has just been completed and is now operational on the ATC machine. The system utilizes four UHF TV klystrons to generate at least 200 kW of power at a frequency of 800 MHz. Pulse widths can be varied from 20 $mu$sec up to 20 msec. A radar type floating deck modulator along with photo-optical transmitting and receiving devices have been incorporated into the system to provide the pulse fidelity and versatility which characterizes this equipment. Modular construction was emphasized in the design, when possible, to reduce maintenance and down time in the advent of component falilure. Hybrid combining techniques are utilized in order to provide two 100 kW feeds into the machine. (auth)
Date: January 1, 1975
Creator: Deitz, A.
System: The UNT Digital Library
A 218 neutron group master cross section library for criticality safety studies (open access)

A 218 neutron group master cross section library for criticality safety studies

The AMPX system was used to generate a P$sub 3$ 218 neutron group master cross-section library from ENDF/B-IV data for the fuel, structural, and neutron- absorbing materials tabulated. The library is the data base for the generation of broad-group cross sections for shipping cask calculations and other criticality safety analyses using codes such as KENO and ANISN. Selection of the fine-group energy structure for the 3-eV to 20-MeV energy range included consideration of the resonance structure of prominent nuclei, the thresholds of important reactions, and the fission spectra. For 10$sup -5$ less than or equal to E/sub n/ less than 3 eV, 78 closely spaced thermal groups were chosen to examine the effects of low-energy resonances and thermal-neutron upscatter. Distribution of the 218 groups within the Hansen-Roach 16-group boundaries is shown. Adequacy of the group structure and validity of selected data sets from the library were tested by P$sub 3$S$sub 8$ XSDRNPM calculations of k-eff for two benchmark critical experiments; first, the 4.9 percent-enriched UO$sub 2$F$sub 2$- H$sub 2$O solution critical sphere experiment of Johnson and Cronin was analyzed, and, second, the 93.2 percent-enriched UO$sub 2$F$sub 2$-H$sub 2$O solution critical sphere experiment of Fox was analyzed. (auth)
Date: January 1, 1975
Creator: Ford, W. E., III; Westfall, R. M. & Webster, C. C.
System: The UNT Digital Library
1024-channel portable gamma-ray spectrometer (open access)

1024-channel portable gamma-ray spectrometer

An instrument is described which is designed to determine radioactive isotope spectra in the field under adverse environmental conditions. The instrument is battery-powered, stores and compares multiple spectra, and performs computations upon the resulting displayed graph. (auth)
Date: November 10, 1975
Creator: McGibbon, A. L.
System: The UNT Digital Library
249cm$sup 3$ Ge(Li) detector for medical imaging (open access)

249cm$sup 3$ Ge(Li) detector for medical imaging

The feasibility of constructing a radioisotope scanner using a Ge(Li) detector with adequate efficiency for clinical use is discussed. (WHK)
Date: January 1, 1975
Creator: Kirby, J. A.; Phelps, P. L.; Sawyer, D.; Armantrout, G. A.; Shipley, W. W.; Atkins, F. B. et al.
System: The UNT Digital Library
2XIIB computer data acquisition system (open access)

2XIIB computer data acquisition system

All major plasma diagnostic measurements from the 2XIIB experiment are recorded, digitized, and stored by the computer data acquisition system. The raw data is then examined, correlated, reduced, and useful portions are quickly retrieved which direct the future conduct of the plasma experiment. This is done in real time and on line while the data is current. The immediate availability of this pertinent data has accelerated the rate at which the 2XII personnel have been able to gain knowledge in the study of plasma containment and fusion interaction. The up time of the experiment is being used much more effectively than ever before. This paper describes the hardware configuration of our data system in relation to various plasma parameters measured, the advantages of powerful software routines to reduce and correlate the data, the present plans for expansion of the system, and the problems we have had to overcome in certain areas to meet our original goals. (auth)
Date: November 18, 1975
Creator: Tyler, G.C.
System: The UNT Digital Library
2XIIB getter material problems (open access)

2XIIB getter material problems

The uniformity of wire characteristics is vital to the reliable long- time operation of the titanium alloy wire. Of particular importance is the diameter, total emissivity, and alloy mix. The getter wire must be operated at a minimum rate while the life is determined by the maximum rate. At a particular current the difference between the maximum and minimum rate is determined by variations in wire characteristics. Small percentage variations in these characteristics can result in large variations in gettering rate. (auth)
Date: November 18, 1975
Creator: Vogtlin, G. E.
System: The UNT Digital Library
2XIIB status (open access)

2XIIB status

The 2XIIB CTR facility at LLL is described with emphasis on the engineering aspects of recent modifications. The current version of the 2X series of magnetic confinement experiments has been operating since the fall of 1974. The 2XIIB relies on pulsed-mirror coils to trap axially-injected low- energy ions. Subsequent heating of the ions is accomplished by energizing additional mirror coils to compress the plasma. Experiments prior to 2XIIB demonstrated plasma trapping and confinement in the pulsed mode. The new feature of 2XIIB is intense beams of electrically neutral atoms that heat the target plasma and sustain its classical losses. The principal goal of on-going experiments is to demonstrate scaling of the eta tau product with mean ion energy via neutral beam injection. This paper is an overview of the engineering developments of the past two years and an introduction to more detailed reports presented at this symposium. (auth)
Date: November 1, 1975
Creator: Bulmer, R. H.; Calderon, M. O.; Hibbs, S. M. & Kozman, T. A.
System: The UNT Digital Library
2XIIB vacuum vessel: a unique design (open access)

2XIIB vacuum vessel: a unique design

The 2XIIB mirror confinement experiment makes unique demands on its vacuum system. The confinement coil set encloses a cavity whose surface is comprised of both simple and compound curves. Within this cavity and at the core of the machine is the operating vacuum which is on the order of 10$sup -9$ Torr. The vacuum container fits inside the cavity, presenting an inside surface suitable for titanium getter pumping and a means of removing the heat load imposed by incandescent sublimator wires. In addition, the cavity is constructed of nonmagnetic and nonconducting materials (nonmetals) to avoid distortion of the pulsed confinement field. It is also isolated from mechanical shocks induced in the machine's main structure when the coils are pulsed. This paper describes the design, construction, and operation of the 2XIIB high-vacuum vessel that has been performing successfully since early 1974. (auth)
Date: November 1, 1975
Creator: Hibbs, S. M. & Calderon, M. O.
System: The UNT Digital Library
Abraham Jefferson Seay, Governor of Oklahoma Territory, 1892-1893 (open access)

Abraham Jefferson Seay, Governor of Oklahoma Territory, 1892-1893

Article describes the life and career of Abraham Jefferson Seay, governor of Oklahoma Territory from 1892-1893. Highlights include the opening of Cheyenne and Arapaho lands and the establishment of Oklahoma State University.
Date: Spring 1975
Creator: Henslick, Harry E.
System: The Gateway to Oklahoma History
Absolute calibration of neutron detectors in the 10-30 MeV range (open access)

Absolute calibration of neutron detectors in the 10-30 MeV range

None
Date: April 30, 1975
Creator: Cookson, J. A.; Hussian, M.; Uttley, C. A.; Fowler, J. L. & Schwartz, R. B.
System: The UNT Digital Library
Absolute measurement of the critical scattering cross section in cobalt (open access)

Absolute measurement of the critical scattering cross section in cobalt

Small-angle neutron scattering techniques have been used to study the angular distribution of the critical scattering from cobalt above T/sub c/. These measurements have been put on an absolute scale by calibrating the critical scattering directly against the nuclear incoherent scattering from cobalt. In this way the interaction range r$sub 1$, which appears in the classical and modified Ornstein--Zernike expressions for the asymptotic form of the spin pair correlation function and is related to the strength of the spin correlations, has been determined. We obtain r$sub 1$/a = 0.46 +- 0.03 for the ratio of the interaction range to the nearest-neighbor distance in cobalt. This result is in good agreement with theoretical predictions. Lack of agreement among previous determinations of the ratio r$sub 1$/a made in iron failed to provide a definitive comparison with theory. (auth)
Date: January 1, 1975
Creator: Glinka, C. J.; Minkiewicz, V. J. & Passell, L.
System: The UNT Digital Library
Absorption and luminescence of glasses during electron irradiation (open access)

Absorption and luminescence of glasses during electron irradiation

None
Date: January 1, 1975
Creator: Swyler, K. J.; Hardy, W. H., II & Levy, P. W.
System: The UNT Digital Library
Absorption corrections for x-ray fluorescence analysis of environmental samples (open access)

Absorption corrections for x-ray fluorescence analysis of environmental samples

The discovery of a very simple and useful relationship between the absorption coefficient of a particular element and the ratio of incoherent to coherent scattering by the sample containing the element is discussed. By measuring the absorption coefficients for a few elements in a few samples, absorption coefficients for many elements in an entire set of similar samples can be obtained. (auth)
Date: August 29, 1975
Creator: Bazan, F. & Bonner, N. A.
System: The UNT Digital Library
Abstracts of contributed papers. Sixth international conference on high- energy physics and nuclear structure, Santa Fe and Los Alamos, NM, June 9--14, 1975 (open access)

Abstracts of contributed papers. Sixth international conference on high- energy physics and nuclear structure, Santa Fe and Los Alamos, NM, June 9--14, 1975

Abstracts of contributed papers are assembled under the following headings (number denotes the number of abstracts in the section): pi p and pi d interactions (10); $pi$ nucleus theory (33); intermediate isobar calculations (8); $pi$-nucleus interactions (25); stopping muons (44); exotic atoms and condensed nuclear states (28); nucleus-nucleus interactions (31); nuclear structure and hypernuclei (7); nucleon-nucleon interactions (24); e- and $gamma$- nucleus interactions (29); weak interactions (17); high energy collisions (13); heavy ions (22); instrumentation (8). (SDF)
Date: August 1, 1975
Creator: Mischke, R.; Hargrove, C. & Hoffman, C.
System: The UNT Digital Library
Acceleration of polarized protons to multi-GeV energies and experiments with polarized protons from 2 to 6 GeV/c (open access)

Acceleration of polarized protons to multi-GeV energies and experiments with polarized protons from 2 to 6 GeV/c

None
Date: January 1975
Creator: Ratner, L. G.
System: The UNT Digital Library
Acceleration techniques for response matrix methods (open access)

Acceleration techniques for response matrix methods

Application of the power iteration method to the multigroup response matrix equations reduces them to a series of one-group problems. Applying acceleration techniques to each of these monoenergetic problems results in substantial reductions in computational effort. The use of point over-relaxation methods in the solution of these equations is described. Over-relaxation is also applied to the outer-iteration eigenvalue and source estimations with considerable success. 10 references. (auth)
Date: January 1, 1975
Creator: Sicilian, J. M. & Pryor, R. J.
System: The UNT Digital Library