Evaluation of Experiment Off-gas System for the EGCR-LITR Capsule Experiment (open access)

Evaluation of Experiment Off-gas System for the EGCR-LITR Capsule Experiment

A proposed modification to the experiment off-gas system for the EGCR-LITR Capsule Experiment is evaluated by comparing the atmospheric radiation doses to laboratory personnel that could result in the event of an experiment failure while utilizing the present off-gas system to those doses that would result if various modifications to the existing system were effected. The modifications considered include the addition of an iodine vapor adsorber and a krypton-xenon adsorber. The addition of an iodine vapor adsorber to the off-gas system, which presently includes an absolute filter, reduces the atmospheric dose to the thyroid from 510 mr to 1.4mr. The total body dose is also reduced from 2.2 to 1.3 mr. The total body dose can be further reduced to 0.7 mr if a large krypton-xenon adsorber is included. Basd upon these calculated atmospheric radiation doses it is concluded that the addition of an activated charcoal iodine vapor adsorber will reduce the atmospheric hazard to an acceptable level.
Date: September 2, 1960
Creator: Adams, R. E. & Browning, W. E.