33 Matching Results

Results open in a new window/tab.

Polarographic Analysis of UNH in the IAW Stream (open access)

Polarographic Analysis of UNH in the IAW Stream

The following report describes two rapid, micro methods for the determination of UNH in Redox waste samples that had been developed fir the concentration range 0.2 to 100 g/l.
Date: January 17, 1949
Creator: Alkire, G. J. & Carson, W. N.
System: The UNT Digital Library
Polarographic Determination of Hexone (open access)

Polarographic Determination of Hexone

The following report describes polarographic methods that determine saturated aliphatic carbonyl compounds.
Date: November 10, 1949
Creator: Alkire, George J.
System: The UNT Digital Library
The Surface Preparation of Uranium for X-Ray Diffraction Studies by the Spectrometer Technique (open access)

The Surface Preparation of Uranium for X-Ray Diffraction Studies by the Spectrometer Technique

A report which describes a number of experiments conducted to compare the effects of different methods of surface preparation on x-ray diffraction patterns of uranium obtained by the spectrometer technique.
Date: March 24, 1949
Creator: Bach, J. H. & Burnham, J. B.
System: The UNT Digital Library
Fast Neutron Sensitivity of the CP Meter (open access)

Fast Neutron Sensitivity of the CP Meter

Abstract: "The sensitivity to fast neutrons of a CP Meter ionization chamber of the type used for health physics beta and gamma survey measurements has been investigated."
Date: June 10, 1949
Creator: Baker, E. E.; Gydesen, F. R. & Whipple, G. H., Jr.
System: The UNT Digital Library
Life of Van Stone Corrective Measures (open access)

Life of Van Stone Corrective Measures

This report is a document summarizing all information available on life aspects of various measures proposed to reduce or eliminate corrosion of Van Stone flanger.
Date: September 12, 1949
Creator: Botsford, C. W. & Eschbach, E. A.
System: The UNT Digital Library
Determination of Organic Acids in Process Solutions (open access)

Determination of Organic Acids in Process Solutions

Abstract: "A method has been established for the estimation of volatile organic acids in aqueous process solutions containing UNH, nitric acid, ANN, sodium dichromate and small amounts of hexone. The practice is to distill a 400 ul or 500 ul sample in the presence of an excess of phosphoric acid and ferrous sulfate under a high vacuum; a special apparatus utilizing a receiver cooled with a dry ice-isopropanol mixture is employed. The distillate is taken up in isopropanol and then titrated potentiometrically with standard potassium hydroxide solution. Since nitric acid and organic acids are present, two end points are observed. The potassium hydroxide added between these end points is equivalent to the organic acids. In the titration, CO2 from the atmosphere or in the potassium hydroxide is a source of error. The former was avoided and correction was made for the latter."
Date: June 29, 1949
Creator: Brouns, R. J. & Pollock, C. W.
System: The UNT Digital Library
Density and Viscosity of Solutions in the Tributyl Phosphate Process for Uranium Recovery (open access)

Density and Viscosity of Solutions in the Tributyl Phosphate Process for Uranium Recovery

The following report discusses the presentation of preliminary density and viscosity data which may explain whether higher viscosities of the Deo Base-TBP systems, and a change in density differences between the two phases will lead to unsatisfactory column operation.
Date: November 29, 1949
Creator: Burger, L. L. & Slansky, C. M.
System: The UNT Digital Library
Properties of the System: Uranyl Nitrate-Aluminum Nitrate - Nitric Acid (or Sodium Hydroxide) - Sodium Nitrate - Water - Hexone (open access)

Properties of the System: Uranyl Nitrate-Aluminum Nitrate - Nitric Acid (or Sodium Hydroxide) - Sodium Nitrate - Water - Hexone

This report discusses properties of the Redox process. Density, apparent molar volumes and viscosity are all described.
Date: March 22, 1949
Creator: Burger, L. L.; Rehn, I. M.; Schmidt, H. R. & Slansky, C. M.
System: The UNT Digital Library
Stepwise Calculation for the Determination of the Number of Transfer Units in Countercurrent Extraction Columns (open access)

Stepwise Calculation for the Determination of the Number of Transfer Units in Countercurrent Extraction Columns

Report discussing a method for the stepwise calculation of the number of transfer units utilized in a given solvent extraction operation. "Use of the method results in a very appreciable saving in time of calculation with an error of 1.5% for the runs tested. The error tends to become smaller with increasing total numbers of transfer units involved."
Date: September 12, 1949
Creator: Burns, W. A. & Eschbach, E. A.
System: The UNT Digital Library
Special Irradiation of Temperature-Indicating Liquid: Final Report--Production Test 105-266-P (open access)

Special Irradiation of Temperature-Indicating Liquid: Final Report--Production Test 105-266-P

A report discussing an experiment conducted to determine the effect of radiation on the melting point of Tempilaq, a commercially available, temperature-indicating liquid.
Date: August 18, 1949
Creator: Carbon, M. W.
System: The UNT Digital Library
The Coulometric Titration of 8-Hydroxyquinoline (open access)

The Coulometric Titration of 8-Hydroxyquinoline

Abstract: "A new method of determining 8-hydroxyquinoline by titration with electrolytucally-generated bromine has been developed. Results show good precision in the range 0.4 mg. to 1.6 mg. total 8-hydroxyquinoline, with 99% confidence limits of less than +/- 2%. An electronically-regulated constant current source, required by the method, is described. A new indicator system with high sensitivity to free bromine is discussed."
Date: June 16, 1949
Creator: Carson, W. N.
System: The UNT Digital Library
The Coulometric Determination of Acetic Acid (open access)

The Coulometric Determination of Acetic Acid

Abstract: "Small amounts of acetic acid, equivalent to 400 ul. of 0.3 to 0.13 g/L. can be titrated coulonatrically in the presence of a 10 to 25-fold excess of HN03 in 70%, isopropanol. An accuracy of +/- 0.1% and a precision of +/- 8.5% (99% limite) are obtained.
Date: August 16, 1949
Creator: Carson, W. N. & Ko, Roy
System: The UNT Digital Library
A Microdetermination of Uranium by Ferric Sulfate Titration (open access)

A Microdetermination of Uranium by Ferric Sulfate Titration

Abstract: "Following nitrate removal by means of a three-stage hydrochloric acid digestion, uranium was reduced with chromous sulfate reagent. In an inert atmosphere, the quadrivalent uranium was titrated at 80-95[degrees] with standard ferric sulfate solution. The end point was obtained with a potentiometric cell including a platinum in-titrant reference electrode and a platinum indicator electrode. Application was made to various low leverl uranium solutions. For samples containing 1 - 12 milligrams or uranium, less than one percent error may be expected. Iron and chromium do not interfere."
Date: February 16, 1949
Creator: Christopherson, E. W.
System: The UNT Digital Library
Purification of Graphite : (Supplementary Document to HW-12780) (open access)

Purification of Graphite : (Supplementary Document to HW-12780)

Report discussing experiments and developments in purification of graphite starting from March, 1949.
Date: October 4, 1949
Creator: Garbrecht, M.
System: The UNT Digital Library
Rate of Burnout of Absorbers (open access)

Rate of Burnout of Absorbers

Report discussing change in absorptivity of some rare earth elements over time.
Date: July 19, 1949
Creator: Gillette, P. R.
System: The UNT Digital Library
The Preparation of Aluminium Nitrate from Hydrated Aluminum Oxides (open access)

The Preparation of Aluminium Nitrate from Hydrated Aluminum Oxides

This report discusses methods of producing aluminum nitrate for the Redox process. Large amounts of aluminum nitrate are consumed during the Redox process, so this report explores preparation of this material through the dissolution of hydrated aluminum oxide in nitric acid.
Date: October 5, 1949
Creator: Harmon, M. K.
System: The UNT Digital Library
The Solvent-Extraction Performance of Redox IC Columns (ANL June 1948 Flowsheet) Using Raschig Ring Packing, and Unirradiated Uranium: Redox Technical Study No. 14 (open access)

The Solvent-Extraction Performance of Redox IC Columns (ANL June 1948 Flowsheet) Using Raschig Ring Packing, and Unirradiated Uranium: Redox Technical Study No. 14

A report which summarizes the performance data obtained from Redox solvent extraction IC Column studies made prior to January 15, 1949 in accordance with conditions of the A.N.L. June 1, 1948, Flowsheet.
Date: August 22, 1949
Creator: Hartzell, L. O.; Woodfield, F. W. & Bradley, J. G.
System: The UNT Digital Library
Urine Analysis for Tritium Oxide (open access)

Urine Analysis for Tritium Oxide

This report analyzes a procedure based on the production of acetylene from the active water, with subsequent measurement of the ionization caused by the tritium beta particle. This eliminates the troublesome absorption on the chamber walls when hydrogen is used, and provides a rapid method for the preparation of the urine samples.
Date: July 27, 1949
Creator: Healy, J. W.
System: The UNT Digital Library
Optical Instruments for the Atomic Industry (open access)

Optical Instruments for the Atomic Industry

The following report presents some points of interest obtained from the use of optical equipment at the Hanford Works; however, this report does not give complete descriptions of the instruments or theories. Full descriptions can be found in the Instrument Division Manual, Section IV.
Date: 1949
Creator: Holeman, J. M.
System: The UNT Digital Library
Corrosion Investigations of Redox Pilot Plant Equipment at Oak Ridge National Laboratories (open access)

Corrosion Investigations of Redox Pilot Plant Equipment at Oak Ridge National Laboratories

The following report is based on the observations made during a visit to the Oak Ride National Laboratories of their Redox Pilot Plant equipment.
Date: November 3, 1949
Creator: Koenig, W. W.
System: The UNT Digital Library
Corrosion Rates of Mild and Stainless Steels Exposed in Redox Stream IAW : (ANL, June 1, 1948 Flowsheet) (open access)

Corrosion Rates of Mild and Stainless Steels Exposed in Redox Stream IAW : (ANL, June 1, 1948 Flowsheet)

Introduction: In order to determine the relative corrosion resistance of welded mild and stainless steels in Redox Stream IAW neutralized to pH 0, 2, and 10 a test program, described below, has been carried out.
Date: November 1, 1949
Creator: Koenig, W. W.
System: The UNT Digital Library
Corrosion Tests on Carboloy in Redox Process Solutions (open access)

Corrosion Tests on Carboloy in Redox Process Solutions

Introduction: Static, total immersion corrosion tests were carried out at room temperatures with Carboloy grades 44-A, 78, 907, X-3119-A and X-3119-B in Redox process solutions (ANL, June 1, 1949 Flowsheet) 1AX, 1AF, and 1AS.
Date: April 6, 1949
Creator: Koenig, W. W.
System: The UNT Digital Library
Parian and Teflon in 1A Redox Solutions (open access)

Parian and Teflon in 1A Redox Solutions

This report analyzes Parian and Teflon that were exposed to solutions of 1AX, 1AS, and 1AF, ANL June 1, 1948 Flowsheet, under conditions described in the following report.
Date: May 9, 1949
Creator: Koenig, W. W.
System: The UNT Digital Library
Corrosion resistance and magnetic susceptibility (open access)

Corrosion resistance and magnetic susceptibility

From summary: "On the basis of the tests described herein, the corrosion characteristics of T-347 welded stainless steel are found not to be affected by the magnetic properties of the welds even though these properties are likely the result of the presence of the ferritic structure."
Date: March 7, 1949
Creator: Koenig, W. W. & Heckman, R. L.
System: The UNT Digital Library