Thermal Transfer to an Annular Water Stream in the Neighborhood of a Rib (open access)

Thermal Transfer to an Annular Water Stream in the Neighborhood of a Rib

Abstract. Steady-state temperatures were measured in an electrically heated brass cylinder which was water cooled in a four-ribbed Al tube. Thermal transfer coefficients h were calculated from the measured temperatures. Curves of h values are presented for the regions of high and low ribs. the h curve is found to show a much sharper break in the region of high rib than in a low rib region. There is some evidence that h decreases linearly with annular thickness in the range considered. The low rib is found to exert a much greater effect than the high rib in decreasing the h value at points distant from the rib.
Date: November 10, 1944
Creator: Kratz, H. R.; Schlegel, R. & Christ, Carl F.