Direct Measurement of the Electric Field of a Laser Pulse--Theory (open access)

Direct Measurement of the Electric Field of a Laser Pulse--Theory

From abstract: This paper presents the conflicts in the design and gives a solution. The complete evaluation requires assembly of the proposed apparatus to assess final accuracy.
Date: August 1985
Creator: Johnson, Eric Gunnar, Jr.
System: The UNT Digital Library
Fitness-for-Service Criteria for Assessing the Significance of Fatigue Cracks in Offshore Structure (open access)

Fitness-for-Service Criteria for Assessing the Significance of Fatigue Cracks in Offshore Structure

Abstract: Results of a research program to develop fitness-for-service criteria for assessing the significance of fatigue cracks in offshore structures are presented in five papers. Each paper describes the goals and approaches to a specific task and details the results of the study.
Date: August 1985
Creator: Cheng, Yi-Wen
System: The UNT Digital Library
A Radio-Frequency Power Delivery System: Procedures for Error Analysis and Self-Calibration (open access)

A Radio-Frequency Power Delivery System: Procedures for Error Analysis and Self-Calibration

Abstract: An expression is developed for net power delivered to a load in terms of the indicated forward and reflected power and the system S-parameters and reflection coefficients. The dual directional coupler is treated as nonideal with power reflections assumed between all ports. The system itself is used to evaluate the major S-parameter terms in net power computation, and uncertainty in the computed power is derived from origins in the power meter readings and incompletely known S-parameters.
Date: August 1985
Creator: Kanda, Motohisa & Orr, R. David
System: The UNT Digital Library
Picosecond Time Difference Measurements Utilizing CAMAC-Based ANSI/IEEE-488 Data Acquisition Hardware : Operating Manual IE3, Version 1.0 (open access)

Picosecond Time Difference Measurements Utilizing CAMAC-Based ANSI/IEEE-488 Data Acquisition Hardware : Operating Manual IE3, Version 1.0

Abstract: Automated time-difference measurements at the picosecond level have been achieved. The system described combines the best properties of three common methods: the single heterodyne measurement technique, the frequency divider, and the dual-mixer time-difference measurement system. This particular system combines two instrumentation standards, ANSI/IFEE-583 and ANSI/IEEE-488 with new, modular dual-mixer time-difference measurement hardware. The modular, standardized hardware together with the new measurement techniques permit the data acquisition modules to be contained in a standard CAMAC crate. This system, along with an external controller, is capable of measuring eiqht clocks, at the present time, and is expandable to twenty-four clocks with modified software and additional measurement modules. The system noise performance is described by a (rT = 3 x 10^-12 t^-1 for time difference measurements.
Date: August 1983
Creator: Glaze, D. J. & Stein, S. R.
System: The UNT Digital Library
Refracted-Ray Scanning (Refracted Near-Field Scanning) for Measuring Index Profiles of Optical Fibers (open access)

Refracted-Ray Scanning (Refracted Near-Field Scanning) for Measuring Index Profiles of Optical Fibers

From introduction: The purpose of this Technical Note is to describe refracted-ray scanning in detail, to analyze it as a measurement system, to document a particular system for implementing it, and to show some exemplary results.
Date: August 1981
Creator: Young, Matt