Direct Strength Method for Web Crippling of Cold-formed Steel C and Z Sections Subjected to Interior One Flange Loading and End One Flange Loading (open access)

Direct Strength Method for Web Crippling of Cold-formed Steel C and Z Sections Subjected to Interior One Flange Loading and End One Flange Loading

The main objective of this research is to extend the “Direct strength method” for determining the web crippling strength of cold-formed steel C and Z sections subjected to End one flange loading and Interior one flange loading conditions. Direct strength method is applied for designing the columns and beams earlier. The existing specifications equation for calculating the web crippling strength of cold-formed steels designed by American Institute of Iron and Steel is very old method and it is based on the extensive experimental investigations conducted at different universities. Calculating the web crippling strength of cold-formed steels using direct strength method is a new technique. In the present research the web crippling strength of cold-formed steels were calculated using Direct Strength Method. The experimental data is collected from the tests that were conducted at different universities. The critical buckling strength of the members were calculated using Abaqus. Microsoft excel is used to generate the equations. The safety and resistance factors for the designed equations were calculated using “Load and resistance factor design” and “Allowable strength design” from North American Cold-Formed Steel Specification, 2012 edition book.
Date: December 2015
Creator: Dara, Martin Luther
System: The UNT Digital Library
Spray Cooling with HFC-134a and HFO-1234yf for Thermal Management of Automotive Power Electronics (open access)

Spray Cooling with HFC-134a and HFO-1234yf for Thermal Management of Automotive Power Electronics

This study aims to experimentally investigate the spray cooling characteristics for active two-phase cooling of automotive power electronics. Tests are conducted on a small-scale, closed loop spray cooling system featuring a pressure atomized spray nozzle. Two types of refrigerants, HFC-134a (R-134a) and HFO-1234yf, are selected as the working fluids. The test section (heater), made out of oxygen-free copper, has a 1-cm2 plain, smooth surface prepared following a consistent procedure, and would serve as a baseline case. Matching size thick film resistors, attached onto the copper heaters, generate heat and simulate high heat flux power electronics devices. The tests are conducted by controlling the heat flux in increasing steps, and recording the corresponding steady-state temperatures to obtain cooling curves. The working fluid is kept at room temperature level (22oC). Performance comparisons are made based on heat transfer coefficient (HTC) and critical heat flux (CHF) values. Effects of spray characteristics and liquid flow rates on the cooling performance are investigated with the selected coolants. Three types of commercially available nozzles that generate full-cone sprays with fine droplets are utilized in the tests. Effect of liquid flow rate is evaluated varying flow rates at 2, 3, 4 ml/s. The experimental results obtained from …
Date: December 2015
Creator: Yaddanapudi, Satvik Janardhan
System: The UNT Digital Library
Development and Test of High-Temperature Piezoelectric Wafer Active Sensors for Structural Health Monitoring (open access)

Development and Test of High-Temperature Piezoelectric Wafer Active Sensors for Structural Health Monitoring

High-temperature piezoelectric wafer active sensors (HT-PWAS) have been developed for structure health monitoring at hazard environments for decades. Different candidates have previously been tested under 270 °C and a new piezoelectric material langasite (LGS) was chosen here for a pilot study up to 700 °C. A preliminary study was performed to develop a high temperature sensor that utilizes langasite material. The Electromechanical impedance (E/M) method was chosen to detect the piezoelectric property. Experiments that verify the basic piezoelectric property of LGS at high temperature environments were carried out. Further validations were conducted by testing structures with attached LGS sensors at elevated temperature. Additionally, a detection system simulating the working process of LGS monitoring system was developed with PZT material at room temperature. This thesis, for the first time, (to the best of author’s knowledge) presents that langasite is ideal for making piezoelectric wafer active sensors for high temperature structure health monitoring applications.
Date: December 2014
Creator: Bao, Yuanye
System: The UNT Digital Library
Direct Immersion Cooling Via Nucleate Boiling of HFE-7100 Dielectric Liquid on Hydrophobic and Hydrophilic Surfaces (open access)

Direct Immersion Cooling Via Nucleate Boiling of HFE-7100 Dielectric Liquid on Hydrophobic and Hydrophilic Surfaces

This study experimentally investigated the effect of hydrophobic and hydrophilic surfaces characteristics on nucleate boiling heat transfer performance for the application of direct immersion cooling of electronics. A dielectric liquid, HFE – 7100 was used as the working fluid in the saturated boiling tests. Twelve types of 1-cm2 copper heater samples, simulating high heat flux components, featured reference smooth copper surface, fully and patterned hydrophobic surface and fully and patterned hydrophilic surfaces. Hydrophobic samples were prepared by applying a thin Teflon coating following photolithography techniques, while the hydrophilic TiO2 thin films were made through a two step approach involving layer by layer self assembly and liquid phase deposition processes. Patterned surfaces had circular dots with sizes between 40 – 250 μm. Based on additional data, both hydrophobic and hydrophilic surfaces improved nucleate boiling performance that is evaluated in terms of boiling incipience, heat transfer coefficient and critical heat flux (CHF) level. The best results, considering the smooth copper surface as the reference, were achieved by the surfaces that have a mixture of hydrophobic/hydrophilic coatings, providing: (a) early transition to boiling regime and with eliminated temperature overshoot phenomena at boiling incipience, (b) up to 58.5% higher heat transfer coefficients, and (c) …
Date: December 2014
Creator: Joshua, Nihal E.
System: The UNT Digital Library
The Measurement of the Third-order Elastic Constants for La3ga5sio14 (Lgs) and La3ga55ta05o14 (Lgt) Single Crystal (open access)

The Measurement of the Third-order Elastic Constants for La3ga5sio14 (Lgs) and La3ga55ta05o14 (Lgt) Single Crystal

Recently, the development of electronic technology towards higher frequencies and larger band widths has led to interest in finding new piezoelectric materials, which could be used to make filters with larger pass band widths and oscillators with better frequency stability. Langasite (La3Ga5SiO14, LGS) and its isomorphs have enticed considerable attention of researchers as a potential substrate material for piezoelectric device applications because of its high frequency stability and fairly good electromechanical coupling factors for acoustic wave devices. Nonlinear effect including drive level dependence, mode coupling, force-frequency effect and electroelasic effect are critical for the design of these devices. Third-order elastic constants (TOEC) play an important role in a quantitative analysis of these nonlinear effects. In particular these elastic constants are of great importance when the BAW (Bulk Acoustic Wave) and SAW (Surface Acoustic Wave) sensors of force, acceleration and so on are designed. Until now Langasite (LGS) and Langatate (LGT) crystal resonators have been qualified in terms of quality factor, temperature effect, isochronism defect and material quality. One of the most important advantages of those crystals is that they will not undergo phase transitions up to its melting temperature of 1450°. Presently there is no data on TOEC of LGT …
Date: December 2013
Creator: Karim, Md Afzalul