Determination of Trivalent Uranium with Methylene Blue (open access)

Determination of Trivalent Uranium with Methylene Blue

A direct titrimetric method for the determination of trivalent uranium in uranium trifluoride and mixtures of fused fluoride salts was developed. The method is based on the stoichiometric oxidation of trivalent uranium to the tetravalent oxidation state with an acidic solution of methylene blue. The sample containing trivalent uranium is dissolved at room temperature in an excess of standard methylene blue solution in a carbon dioxide atmosphere; the excess oxidant is variation of the method is 1.5 per cent for 5 mg quantities of trivalent uranium. The method was applied to various mixtures of fluoride salts containing both trivalent and tetravalent uranium.
Date: November 22, 1955
Creator: Ross, W. J.; Meyer, A. S.; White, J. C.; Kelley, N. T. & Susano, C. D.
System: The UNT Digital Library
A Study of the Mechanism of Radiation Induced Gelation in Monomer-Polymer Mixtures (open access)

A Study of the Mechanism of Radiation Induced Gelation in Monomer-Polymer Mixtures

"Additional mixtures of polymers and multi-unsaturated monomers have been prepared, irradiated and the gel content determined. The gel content determination of crosslinked polyolefins has been investigated in detail. The multi-unsaturated monomers used and radiation conditions applied up to this time have not given significant gel contents for polypropylene. the polypropylene resin used has been characterized by differential extraction."
Date: November 22, 1960
Creator: unknown
System: The UNT Digital Library
Observations on the Response of Two P-NJunction Diodes to Protons (open access)

Observations on the Response of Two P-NJunction Diodes to Protons

The response of a two silicon p-n junction diodes has been measured for protons up to 13.3 Mev. In one case the dependence of depletion layer thickness with bias voltage was found to be T or V(0.46). The observed resolution, made up of contributions from crystal noise, beam width, and scatterer thickness, was about 1% for 9-Mev protons.
Date: November 22, 1960
Creator: Benveniste, J.; Booth, R. & Mitchell, A. C.
System: The UNT Digital Library
Purification of Mercury Metal (open access)

Purification of Mercury Metal

Mercury to be used in polarography as a dropping mercury electrode must be of the highest purity. The author has found that much of the commercial "triple-distilled" mercury as well as that which is repurified on site is not sufficiently pure and because of this, a study of mercury purification techniques was made and a very satisfactory procedure was tested thoroughly. This procedure is described in detail in this report.
Date: November 22, 1955
Creator: Koyama, Karl
System: The UNT Digital Library