D0 Silicon Upgrade: Control Dewar Valve Calculations (open access)

D0 Silicon Upgrade: Control Dewar Valve Calculations

This engineering note documents the calculations that were done to support the valve size selection for the magnet flow control valve, EVMF in the solenoid control dewar. The size selected was a control valve with a Cv = 0.32.
Date: October 20, 1995
Creator: Rucinski, Russ
Object Type: Report
System: The UNT Digital Library
D0 Silicon Upgrade: Flowdyne Flow Element Information for D-Zero Upgrade (open access)

D0 Silicon Upgrade: Flowdyne Flow Element Information for D-Zero Upgrade

This engineering note provides the information used for purchasing two venturi flowmeters and one orifice flowmeter. One venturi and one orifice performance curve is provided along with the purchasing information. Performance data is also given to supplement the performance curves.
Date: October 3, 1995
Creator: Kuwazaki, Andrew
Object Type: Report
System: The UNT Digital Library
D0 Silicon Upgrade: ASME Code and Pressure Calculations for Liquid Nitrogen Subcooler (open access)

D0 Silicon Upgrade: ASME Code and Pressure Calculations for Liquid Nitrogen Subcooler

Included in this engineering note are three separate calculation divisions. The first calculations are the determination of the required thickness of the LN{sub 2} subcooler flat head according to ASME code. This section includes Appendix A-C. The minimum plate thickness determined was 0.563 in. The actual thickness chosen in fabrication was a 3/4-inch plate milled to 0.594-inch at the bolt circle. Along with the plate thickness, this section calculates the required reinforcement area at the top plate penetrations. It was found that a 1/4-inch fillet weld at each penetration was adequate. The next set of calculations were done to prove that the subcooler internal pressure will always be less than 15 psig and therefore will not be classified as a pressure vessel. The subcooler is always open to a vent pipe. Appendix D calculations show that the vent pipe has a capacity of 1042 lbs/hr if 15 psig is present at the subcooler. It goes on to show that the inlet piping would at that flow rate, see a pressure drop of 104 psig. The maximum supply pressure of the LN{sub 2} storage dewar is 50 psig. Appendix E addresses required flow rates for steady state, loss of vacuum, or …
Date: October 4, 1995
Creator: Kuwazaki, Andrew & Leicht, Todd
Object Type: Report
System: The UNT Digital Library
Gas and Particulate Sampling of Airborne Polycyclic Aromatic Compounds (open access)

Gas and Particulate Sampling of Airborne Polycyclic Aromatic Compounds

The denuder surfaces of the gas and particle (GAP) sampler (developed at the Atmospheric Environment Service of Environment Canada) have been modified by coating with XAD-4 resin, using techniques developed at Lawrence Berkeley National Laboratory (LBNL) for the lower capacity integrated organic vapor/particle sampler (IOVPS). The resulting high capacity integrated organic gas and particle sampler (IOGAPS) has been operated in ambient air at 16.7 L min{sup -1} for a 24-hour period in Berkeley, California, USA. Simultaneous measurements were made at the same collection rate with a conventional sampler that used a filter followed by two sorbent beds. Gas and particle partition measurements were determined for 13 polycyclic aromatic hydrocarbons (PAH) ranging from 2-ring to 6-ring species. The IOGAPS indicated a higher particle fraction of these compounds than did the conventional sampler, suggesting that the conventional sampler suffered from 'blow-off' losses from the particles collected on the filter.
Date: October 1, 1995
Creator: Lane, D.A. & Gundel, L.A.
Object Type: Article
System: The UNT Digital Library
D0 Silicon Upgrade: Control Dewar Steady State Thermodynamic Operating Goals (open access)

D0 Silicon Upgrade: Control Dewar Steady State Thermodynamic Operating Goals

This engineering note documents the thermodynamic operating parameter goals for the steady state operation of the control dewar/solenoid system. Specifically, how the control dewar pressure control valve, PV-3062-H and the magnet flow control valve EVMF are operated to give the lowest possible temperature fluid at the solenoid magnet. The goals are: (1) For PV-3062-H - The process variable is the helium reservoir pressure, minimize the reservoir pressure, provide only enough pressure plus a little margin to ensure leads flow; and (2) For EVMF - The process variable is firstly a manual setpoint of flowrate as read by the flow venturi, FE3253-H, and secondly the reservoir liquid level, minimize the pressure drop thru the solenoid cooling tubes, provide at least enough flow to maintain reservoir level and stable operation of the magnet. The thermodynamic states for the fluid thru the system are shown on the Pressure versus Temperature graph. Lines of constant enthalpy are also shown. State A is shown as two phase liquid entering the inlet of the subcooler. The subcooler subcools the fluid to State B. State B to State C is caused by the pressure drop across EVMF. State C to D is the estimated pressure drop from …
Date: October 20, 1995
Creator: Rucincki, Russ
Object Type: Report
System: The UNT Digital Library
D0 Silicon Upgrade: Cryolab Control Valve Modification Information for D0-EVMF-H (open access)

D0 Silicon Upgrade: Cryolab Control Valve Modification Information for D0-EVMF-H

This engineering note documents some information regarding the solenoid magnet flow valve, EVMF. See also EN-437 'Control Dewar valve sizing' also for further information on this valve. This note documents the modification done to the valve to change it to a Cv = 0.32.
Date: October 26, 1995
Creator: Rucincki, Russ
Object Type: Report
System: The UNT Digital Library
D0 Silicon Upgrade: Liquid Nitrogen Subcooler Coil Sizing for D-Zero Upgrade (open access)

D0 Silicon Upgrade: Liquid Nitrogen Subcooler Coil Sizing for D-Zero Upgrade

The raw calculations are attached as Appendix A. The calculations provide the analysis of the heat transferred while the LN{sub 2} subcooler is in use. In order to achieve an acceptable conclusion, the assumption of a fully developed thermal boundary layer was made. The hot fluid or the fluid condensing on the inside surface will determine the rate of heat transfer because A{sub o} = A{sub i} and h{sub o}A{sub o} >> h{sub i}A{sub i}. The conclusion drawn is to use a 1/2-inch OD copper tube wound approximately 8 times about an 8-inch diameter circle. There are also calculations concerning the size of the nitrogen supply and subcooler vent. The maximum mass flow rate was determined as 52.5 g/s and the sizing of the nitrogen supply and subcooler vent should be chosen accordingly.
Date: October 3, 1995
Creator: Kuwazaki, Andrew & Leicht, Todd
Object Type: Report
System: The UNT Digital Library
A hierarchy of ECM-mediated signalling tissue-specific gene expression regulates tissue-specific gene expression (open access)

A hierarchy of ECM-mediated signalling tissue-specific gene expression regulates tissue-specific gene expression

A dynamic and reciprocal flow of information between cells and the extracellular matrix contributes significantly to the regulation of form and function in developing systems. Signals generated by the extracellular matrix do not act in isolation. Instead, they are processed within the context of global signalling hierarchies whose constituent inputs and outputs are constantly modulated by all the factors present in the cell's surrounding microenvironment. This is particularly evident in the mammary gland, where the construction and subsequent destruction of such a hierarchy regulates changes in tissue-specific gene expression, morphogenesis and apoptosis during each developmental cycle of pregnancy, lactation and involution.
Date: October 7, 1995
Creator: Roskelley, Calvin D; Srebrow, Anabella & Bissell, Mina J
Object Type: Article
System: The UNT Digital Library
Yucca Mountain Site Charecterization Project Design Package 1C System Safety Analysis (open access)

Yucca Mountain Site Charecterization Project Design Package 1C System Safety Analysis

The purpose of this analysis is to systematically identify and evaluate hazards related to the Yucca Mountain Project Exploratory Studies Facility (ESF) Design Package IC, Surface Utilities (for a list of package 1C subsystems see section 3). This process is an integral part of the systems engineering process; whereby safety is considered during planning, design, testing, and construction. A largely qualitative approach was used since a radiological System Safety Analysis is not required. The risk assessment in this analysis characterizes the accident scenarios associated with the Design Package 1C structures/systems/components in terms of relative risk and includes recommendations for mitigating all identified risks. The priority for recommending and implementing mitigation control features is: (1) Incorporate measures to reduce risks and hazards into the structure/system/component (S/S/C) design, (2) add safety devices and capabilities to the designs that reduce risk, (3) provide devices that detect and warn personnel of hazardous conditions, and (4) develop procedures and conduct training to increase worker awareness of potential hazards, on methods to reduce exposure to hazards, and on the actions required to avoid accidents or correct hazardous conditions. The scope of this analysis is limited to the Design Package 1C structures/systems/components (S/S/Cs) during normal operations. Hazards …
Date: October 16, 1995
Creator: TRW
Object Type: Report
System: The UNT Digital Library
Can the Lack of Symmetry in the COBE/DMR Maps Constraian theTopology of the Universe? (open access)

Can the Lack of Symmetry in the COBE/DMR Maps Constraian theTopology of the Universe?

None
Date: October 6, 1995
Creator: de Oliveira-Costa, A.; Smoot, George F. & Starobinsky, A. A.
Object Type: Article
System: The UNT Digital Library
IMPACT EVALUATION FOR THE MANUFACTURED HOUSING ACQUISITION PROGRAM (MAP) (open access)

IMPACT EVALUATION FOR THE MANUFACTURED HOUSING ACQUISITION PROGRAM (MAP)

This report presents the results of an impact evaluation of the Manufactured Housing Acquisition Program. This evaluation was conducted for Bonneville by Pacific Northwest Laboratory to determine MAP's energy impacts and cost-effectiveness. We conducted a three-tiered analysis of the utility billing data to estimate program electriccty savings. The first (a raw billing data comparison and simple regression analysis) and second (PRISM) tier analyses provided useful findings for the third-tier analysis by which program savings were estimated. The third-tier approach used a conditional demand type regression analysis to analyze monthly energy consumption, taking into account significant factors likely to influence electricrty usage. We used the regression results to estimate energy savings under "normal" weather conditions for each climate zone. We determined cost-effectiveness by calculating levelized costs using a methodology published by Bonneville. We analyzed potential market transformation effects from a conceptual viewpoint. Our results suggested that MAP's market transformation benefits probably reduced the levelized cost to utilities by 40% or more.
Date: October 1, 1995
Creator: Lee, A. D.; Taylor, Z. T.; Schrock, D. W.; Sandahl, L. J.; Chin, R. I. & Kavanauagh, D. C.
Object Type: Report
System: The UNT Digital Library
ATR Operations Document Revision 1.0 (open access)

ATR Operations Document Revision 1.0

This document consists almost entirely of World Wide Web pages, that have been printed as postscript files, and compiled into one enormous note.
Date: October 25, 1995
Creator: MacKay, W.; Satogata, T. & Tanaka, S.
Object Type: Report
System: The UNT Digital Library
An Assessment of the U.S. Residential Lighting Market (open access)

An Assessment of the U.S. Residential Lighting Market

This report provides background data upon which residential lighting fixture energy conservation programs can be built. The current stock of residential lighting is described by usage level, lamp wattage, fixture type, and location within the house. Data are discussed that indicate that 25% of residential fixtures are responsible for 80% of residential lighting energy use, and that justify targeting these fixtures as candidates for retrofit with energy-efficient fixtures. Fixtures determined to have the highest energy use are hardwired ceiling fixtures in kitchens, living/family rooms, dining rooms, and outdoors. An assessment of the market for residential fixtures shows that nearly half of new residential fixtures are imported, 61% of new fixtures sold are hardwired, and about half of all new fixtures sold are for ceiling installation.
Date: October 1, 1995
Creator: Jennings, Judy; Brown, Rich; Moezzi, Mithra; Mills, Evan & Sardinsky, Robert
Object Type: Report
System: The UNT Digital Library
HIGH CHARGE EFFECTS IN SILICON DRIFT DETECTORS WITH LATERAL CONFINEMENT OF ELECTRONS. (open access)

HIGH CHARGE EFFECTS IN SILICON DRIFT DETECTORS WITH LATERAL CONFINEMENT OF ELECTRONS.

A new drift detector prototype which provides suppression of the lateral diffusion of electrons has been tested as a function of the signal charge up to high charge levels, when electrostatic repulsion is not negligible. The lateral diffusion of the electron cloud has been measured for injected charges up to 2 {center_dot} 10{sup 5} electrons. The maximum number of electrons for which the suppression of the lateral spread is effective is obtained.
Date: October 21, 1995
Creator: CASTOLDI,A. & REHAK,P.
Object Type: Article
System: The UNT Digital Library
INITIAL WASTE PACKAGE PROBABILISTIC CRITICALITY ANALYSIS: MULTI-PURPOSE CANISTER WITH DISPOSAL CONTAINER (TBV) (open access)

INITIAL WASTE PACKAGE PROBABILISTIC CRITICALITY ANALYSIS: MULTI-PURPOSE CANISTER WITH DISPOSAL CONTAINER (TBV)

This analysis is prepared by the Mined Geologic Disposal System (MGDS) Waste Package Development Department (WPDD) to provide an assessment of the present waste package design from a criticality risk standpoint. The specific objectives of this initial analysis are to: (1) Establish a process for determining the probability of waste package criticality as a function of time (in terms of a cumulative distribution function, probability distribution function, or expected number of criticalities in a specified time interval) for various waste package concepts; (2) Demonstrate the established process by estimating the probability of criticality as a function of time since emplacement for an intact multi-purpose canister waste package (MPC-WP) configuration; (3) Identify the dominant sequences leading to waste package criticality for subsequent detailed analysis. The purpose of this analysis is to document and demonstrate the developed process as it has been applied to the MPC-WP. This revision is performed to correct deficiencies in the previous revision and provide further detail on the calculations performed. This analysis is similar to that performed for the uncanistered fuel waste package (UCF-WP, B00000000-01717-2200-00079).
Date: October 6, 1995
Creator: Massari, J. R.
Object Type: Report
System: The UNT Digital Library
INITIAL WASTE PACKAGE PROBABILISTIC CRITICALITY ANALYSIS: UNCANISTERED FUEL (TBV) (open access)

INITIAL WASTE PACKAGE PROBABILISTIC CRITICALITY ANALYSIS: UNCANISTERED FUEL (TBV)

This analysis is prepared by the Mined Geologic Disposal System (MGDS) Waste Package Development Department (WPDD) to provide an assessment of the present waste package design from a criticality risk standpoint, The specific objectives of this initial analysis are to: (1) Establish a process for determining the probability of waste package criticality as a function of time (in terms of a cumulative distribution function, probability distribution function, or expected number of criticalities in a specified time interval) for various waste package concepts; (2) Demonstrate the established process by estimating the probability of criticality as a function of time since emplacement for an intact uncanistered fuel waste package (UCF-WP) configuration; and (3) Identify the dominant sequences leading to waste package criticality for subsequent detailed analysis. The purpose of this analysis is to document and demonstrate the developed process as it has been applied to the UCF-WP. This revision is performed to correct deficiencies in the previous revision and provide further detail on the calculations performed. Due to the current lack of knowledge in a number of areas, every attempt has been made to ensure that the all calculations and assumptions were conservative. This analysis is preliminary in nature, and is intended …
Date: October 6, 1995
Creator: Massari, J. R.
Object Type: Report
System: The UNT Digital Library
Emergency radiological monitoring and analysis: Federal Radiological Monitoring and Assessment Center (open access)

Emergency radiological monitoring and analysis: Federal Radiological Monitoring and Assessment Center

The US Federal Radiological Emergency Response Plan (FRERP) provides the framework for integrating the various Federal agencies responding to a major radiological emergency. The FRERP authorizes the creation of the Federal Radiological Monitoring and Assessment Center (FRMAC), which is established to coordinate all Federal agencies involved in the monitoring and assessment of the off-site radiological conditions in support of the impacted State(s) and the Lead Federal Agency (LFA). Within the FRMAC, the Monitoring and Analysis Division (M&A) is responsible for coordinating all FRMAC assets involved in conducting a comprehensive program of environmental monitoring, sampling, radioanalysis, and quality assurance. To assure consistency, completeness, and the quality of the data produced, a methodology and procedures manual is being developed. This paper discusses the structure, assets, and operations of the FRMAC M&A and the content and preparation of the manual.
Date: October 1, 1995
Creator: Thome, D.J.
Object Type: Article
System: The UNT Digital Library
Calendar year 1994 groundwater quality report for the Upper East Fork Poplar Creek Hydrogeologic Regime, Y-12 Plant, Oak Ridge, Tennessee (open access)

Calendar year 1994 groundwater quality report for the Upper East Fork Poplar Creek Hydrogeologic Regime, Y-12 Plant, Oak Ridge, Tennessee

This groundwater quality report (GWQR) contains an evaluation of the groundwater quality data obtained during the 1994 calendar year (CY) at several waste-management facilities and a petroleum fuel underground storage tank (UST) site at the US Department of Energy (DOE) Y-12 Plant located on the DOE Oak Ridge Reservation (ORR) southeast of Oak Ridge, Tennessee. These sites lie within the boundaries of the Upper East Fork Poplar Creek Hydrogeologic Regime (East Fork Regime), which is one of three hydrogeologic regimes defined for the purposes of groundwater quality monitoring at the Y-12 Plant. The Environmental Management Department of the Y-12 Plant Health, Safety, Environment, and Accountability (HSEA) Organization manages the groundwater monitoring activities in each regime under the auspices of the Y-12 Plant Groundwater Protection Program (GWPP). The purpose of the GWPP is to characterize the hydrogeology and to monitor groundwater quality at the Y-12 Plant and surrounding area to ensure protection of local groundwater resources in accordance with federal, state, and local regulations, DOE Orders, and Lockheed Martin Energy Systems, Inc. (Energy Systems) corporate policy.
Date: October 1, 1995
Creator: unknown
Object Type: Report
System: The UNT Digital Library
Application of knowledge-based network processing to automated gas chromatography data interpretation (open access)

Application of knowledge-based network processing to automated gas chromatography data interpretation

A method of translating a two-way table of qualified symptom/cause relationships into a four layer Expert Network for diagnosis of machine or sample preparation failure for Gas Chromatography is presented. This method has proven to successfully capture an expert`s ability to predict causes of failure in a Gas Chromatograph based on a small set of symptoms, derived from a chromatogram, in spite of poorly defined category delineations and definitions. In addition, the resulting network possesses the advantages inherent in most neural networks: the ability to function correctly in the presence of missing or uncertain inputs and the ability to improve performance through data-based training procedures. Acquisition of knowledge from the domain experts produced a group of imprecise cause-to-symptom relationships. These are reproduced as parallel pathways composed of Symptom-Filter-Combination-Cause node chains in the network representation. Each symptom signal is passed through a Filter node to determine if the signal should be interpreted as positive or negative evidence and then modified according to the relationship established by the domain experts. The signals from several processed symptoms are then combined in the Combination node(s) for a given cause. The resulting value is passed to the Cause node and the highest valued Cause node …
Date: October 1, 1995
Creator: Levis, A.P.; Timpany, R.G. & Klotter, D.A.
Object Type: Article
System: The UNT Digital Library
A laboratory and pilot plant scaled continuous stirred reactor separator for the production of ethanol from sugars, corn grits/starch or biomass streams (open access)

A laboratory and pilot plant scaled continuous stirred reactor separator for the production of ethanol from sugars, corn grits/starch or biomass streams

An improved bio-reactor has been developed to allow the high speed, continues, low energy conversion of various substrates to ethanol. The Continuous Stirred Reactor Separator (CSRS) incorporates gas stripping of the ethanol using a recalculating gas stream between cascading stirred reactors in series. We have operated a 4 liter lab scale unit, and built and operated a 24,000 liter pilot scale version of the bioreactor. High rates of fermentation are maintained in the reactor stages using a highly flocculent yeast strain. Ethanol is recovered from the stripping gas using a hydrophobic solvent absorber (isothermal), after which the gas is returned to the bioreactor. Ethanol can then be removed from the solvent to recover a highly concentrated ethanol product. We have applied the lab scale CSRS to sugars (glucose/sucrose), molasses, and raw starch with simultaneous saccharification and fermentation of the starch granules (SSF). The pilot scale CSRS has been operated as a cascade reactor using dextrins as a feed. Operating data from both the lab and pilot scale CSRS are presented. Details of how the system might be applied to cellulosics, with some preliminary data are also given.
Date: October 1, 1995
Creator: Dale, M.C.; Lei, Shuiwang & Zhou, Chongde
Object Type: Article
System: The UNT Digital Library
Waste Tank Vapor Program: Vapor space characterization of waste tank 241-C-110. Results from samples collected on August 18, 1994 (open access)

Waste Tank Vapor Program: Vapor space characterization of waste tank 241-C-110. Results from samples collected on August 18, 1994

This document presents the details of the inorganic and organic analysis that was performed on samples from the headspace of Hanford waste tank 24l-C-110. The results described were obtained to support the safety and toxicological evaluations. A summary of the results for the inorganic and organic analytes is included, as well as, a detailed description of the results which appears in the text.
Date: October 1, 1995
Creator: Ligotke, M. W.; Clauss, T. W. & Pool, K. H.
Object Type: Report
System: The UNT Digital Library
Barrier/Cu contact resistivity (open access)

Barrier/Cu contact resistivity

The specific contact resistivity of Cu with ({alpha} + {beta})-Ta, TiN, {alpha}-W, and amorphous-Ta{sub 36}Si{sub 14}N{sub 50} barrier films is measured using a novel four-point-probe approach. Geometrically, the test structures consist of colinear sets of W-plugs to act as current and voltage probes that contact the bottom of a planar Cu/barrier/Cu stack. Underlying Al interconnects link the plugs to the current source and voltmeter. The center-to-center distance of the probes ranges from 3 to 200 {micro}m. Using a relation developed by Vu et al., a contact resistivity of roughly 7 {times} 10{sup {minus}9} {Omega} cm{sup 2} is obtained for all tested barrier/Cu combinations. By reflective-mode small-angle X-ray scattering, the similarity in contact resistivity among the barrier films may be related to interfacial impurities absorbed from the deposition process.
Date: October 17, 1995
Creator: Reid, J.S.; Nicolet, M.A.; Angyal, M.S.; Lilienfeld, D.; Shacham-Diamand, Y. & Smith, P.M.
Object Type: Report
System: The UNT Digital Library
Integration/coordination contractor support to Environmental Restoration Program and Program Support Office. Contract status report, September 1, 1995--September 30, 1995 (open access)

Integration/coordination contractor support to Environmental Restoration Program and Program Support Office. Contract status report, September 1, 1995--September 30, 1995

This status report updates activities on the following tasks: Environmental restoration task planning; Waste management task planning; Waste management project support; CPP stakeholder involvement; EM site specific advisory board - Idaho National Engineering Laboratory; and, Hypermedia document. A summary status assessment and forecast of all tasks is provided and A cost management report is included.
Date: October 1, 1995
Creator: unknown
Object Type: Report
System: The UNT Digital Library
Total carbon dioxide, hydrographic, and nitrate measurements in the Southwest Pacific during Austral autumn, 1990: Results from NOAA/PMEL CGC-90 cruise (open access)

Total carbon dioxide, hydrographic, and nitrate measurements in the Southwest Pacific during Austral autumn, 1990: Results from NOAA/PMEL CGC-90 cruise

In support of the National Oceanic and Atmospheric Administration (NOAA) Climate and Global Change (C&GC) Program, Pacific Marine Environmental Laboratory (PMEL) scientists have been measuring the growing burden of greenhouse gases in the thermocline waters of the Pacific Ocean since 1980. Collection of data at a series of hydrographic stations along longitude 170{degrees} W during austral autumn of 1990 was designed to enhance understanding of the increase in the column burden of chlorofluorocarbons and carbon dioxide in the thermocline waters since the last expedition in 1984. This document presents the procedures and methods used to obtain total carbon dioxide (TCO{sub 2}), hydrographic, and nitrate data during the NOAA/PMEL research vessel (R/V) Malcolm Baldrige CGC-90 Cruise. Data were collected along two legs; sampling for Leg 1 began along 170{degrees} W from 15{degrees} S to 60{degrees} S, then angled northwest toward New Zealand across the Western Boundary Current. Leg 2 included a reoccupation of some stations between 30{degrees} S and 15{degrees} S on 170{degrees} W and measurements from 15{degrees} S to 5{degrees} N along 170{degrees} W. The following data report summarizes the TCO{sub 2}, salinity, temperature, and nitrate measurements from 63 stations. The TCO, concentration in seawater samples was measured using a …
Date: October 1995
Creator: Lamb, M. F.; Feely, R. A. & Moore, L.
Object Type: Report
System: The UNT Digital Library