Degree Discipline

Cold-Formed Steel Bolted Connections Using Oversized and Slotted Holes without Washers (open access)

Cold-Formed Steel Bolted Connections Using Oversized and Slotted Holes without Washers

In cold-formed steel (CFS) construction, bolted connections without washers for either oversized or slotted holes may significantly expedite the installation process and lower the cost. However, the North American Specification (AISI S100, 2007) for the Design of Cold-Formed Steel Structural Members requires washers to be installed in bolted connections with oversized or slotted holes. A research project (Phase 1) sponsored by American Iron and Steel Institute (AISI) was recently completed at the University of North Texas (UNT) that investigated the performance and strength of bolted CFS connections with oversized and slotted holes without using washers. The research presented in this thesis is the Phase 2 project in which the bolted CFS connections were studied in a broader respect in terms of the failure mechanism, the material thickness, and the hole configurations. Single shear and double shear connections without washers using oversized holes, oversized combined with standard or slotted holes were experimentally examined. Combined with Phase 1 results, the Phase 2 gives a comprehensive evaluation of the behavior and strength of bolted CFS connections with oversized and slotted holes without using washers. Revisions to the existing AISI North American Specification requirements for bolted connections are proposed to account for the reduction …
Date: August 2010
Creator: Xu, Ke
System: The UNT Digital Library
Nominal Shear Strength and Seismic Detailing of Cold-formed Steel Shear Walls using Steel Sheet Sheathing (open access)

Nominal Shear Strength and Seismic Detailing of Cold-formed Steel Shear Walls using Steel Sheet Sheathing

In this research, monotonic and cyclic tests on cold-formed steel shear walls sheathed with steel sheets on one side were conducted to (1) verify the published nominal shear strength for 18-mil and 27-mil steel sheets; and (2) investigate the behavior of 6-ft. wide shear walls with multiple steel sheets. In objective 1: this research confirms the discrepancy existed in the published nominal strength of 27-mil sheets discovered by the previous project and verified the published nominal strength of 18 mil sheet for the wind design in AISI S213. The project also finds disagreement on the nominal strength of 18-mil sheets for seismic design, which is 29.0% higher than the published values. The research investigated 6-ft. wide shear wall with four framing and sheathing configurations. Configuration C, which used detailing, could provide the highest shear strength, compared to Configurations A and B. Meanwhile, the shear strength and stiffness of 2-ft. wide and 4-ft. wide wall can be improved by using the seismic detailing.
Date: August 2010
Creator: Chen, Yujie
System: The UNT Digital Library
Factors influencing horizontal cracking in continuously reinforced concrete pavements (CRCP). (open access)

Factors influencing horizontal cracking in continuously reinforced concrete pavements (CRCP).

This research presents the results on an experimental investigation to identify the significant factors influencing horizontal cracking in continuously reinforced concrete pavements (CRCP). An in-depth analysis of the microstructure, morphological characteristics of the interfacial transition zone (ITZ) and the observation of cracking using the environmental scanning electron microscope (ESEM) was done. Characterization of oxides using Fourier transform infrared spectroscopy (FTIR) and electron dispersive x-ray spectroscopy (EDS) was also performed. Water to cement ratio (w/c) and rebar temperature had a significant influence on the rebar-concrete bond strength. The 28-day shear strength measurements showed an increase in rebar-concrete bond strength as the water to cement ratio (w/c) was reduced from 0.50 to 0.40. There was a reduction in the peak pullout load as the temperature increased from 14oF to 252oF for the corroded and non-corroded rebar experiments. The corroded rebar pullout test results showed a 20-50 % reduction in bond strength compared to the non-corroded rebars. FTIR measurements indicated a presence of lepidocrocrite (γ -FeOOH) and maghemite (γ -Fe2O3) on the ITZ. ESEM images showed the existence of microcracks as early as three days after casting with the bridging of these cracks between coarse aggregate locations in the interfacial zone propagating through …
Date: August 2008
Creator: Sudoi, Elias K.
System: The UNT Digital Library
A Verilog 8051 Soft Core for FPGA Applications (open access)

A Verilog 8051 Soft Core for FPGA Applications

The objective of this thesis was to develop an 8051 microcontroller soft core in the Verilog hardware description language (HDL). Each functional unit of the 8051 microcontroller was developed as a separate module, and tested for functionality using the open-source VHDL Dalton model as benchmark. These modules were then integrated to operate as concurrent processes in the 8051 soft core. The Verilog 8051 soft core was then synthesized in Quartus® II simulation and synthesis environment (Altera Corp., San Jose, CA, www.altera.com) and yielded the expected behavioral response to test programs written in 8051 assembler residing in the v8051 ROM. The design can operate at speeds up to 41 MHz and used only 16% of the FPGA fabric, thus allowing complex systems to be designed on a single chip. Further research and development can be performed on v8051 to enhance performance and functionality.
Date: August 2009
Creator: Rangoonwala, Sakina
System: The UNT Digital Library