Degree Department

Analysis of Acid Gas Emissions in the Combustion of the Binder Enhanced d-RDF by Ion Chromatography (open access)

Analysis of Acid Gas Emissions in the Combustion of the Binder Enhanced d-RDF by Ion Chromatography

Waste-to-energy has become an attractive alternative to landfills. One concern in this development is the release of pollutants in the combustion process. The binder enhanced d-RDF pellets satisfy the requirements of environmental acceptance, chemical/biological stability, and being storeable. The acid gas emissions of combusting d-RDF pellets with sulfur-rich coal were analyzed by ion chromatography and decreased when d-RDF pellets were utilized. The results imply the possibility of using d-RDF pellets to substitute for sulfur-rich coal as fuel, and also substantiate the effectiveness of a binder, calcium hydroxide, in decreasing emissions of SOx. In order to perform the analysis of the combustion sample, sampling and sample pretreatment methods prior to the IC analysis and the first derivative detection mode in IC are investigated as well. At least two trapping reagents are necessary for collecting acid gases: one for hydrogen halides, and the other for NOx and SOx. Factors affecting the absorption of acid gases are studied, and the strength of an oxidizing agent is the main factor affecting the collection of NOx and SOx. The absorption preference series of acid gases are determined and the absorption models of acid gases in trapping reagents are derived from the analytical results. To prevent …
Date: August 1988
Creator: Jen, Jen-Fon
System: The UNT Digital Library
Molecular Dynamics in the Liquid Phase by FT-NMR, FT-IR and Laser Raman Lineshape Analysis (open access)

Molecular Dynamics in the Liquid Phase by FT-NMR, FT-IR and Laser Raman Lineshape Analysis

Nuclear magnetic resonance (NMR) provides a convenient probe for the study of molecular reorientation in liquids because nuclear spin-lattice relaxation times are dependent upon the details of molecular motion. The combined application of Raman and Infrared (IR) lineshape analysis can furnish more complete information to characterize the anisotropic rotation of molecules. Presented here are the studies of NMR relaxation times, together with Raman/IR Mneshape analysis of the solvent and temperature dependence of rotational diffusion in 1,3,5-tribromobenzene and 1,3,5-trifluorobenzene. In these experiments, it was found that the rotational diffusion constants calculated from Perrin's stick model were two to three times smaller than the measured values of D, and D,,. Similarly, rotational diffusion constants predicted by the Hu-Zwanzig slip model were too large by a factor of 2. Application of the newer Hynes-Kapral-Weinberg model furnished rotational diffusion constants that were in reasonable agreement with the experimental results. The vibrational peak frequencies and relaxation times of the isotropic Raman spectra of the υ1 modes of CD2Br2 and CHBr3 were studied in solution. The frequency shifts in non-interactive solvents were explained well on the basis of solution variations in the dispersion energy. In Lewis bases, the displacements were in some, but not all, cases …
Date: August 1988
Creator: Chen, Fu-Tseng Andy
System: The UNT Digital Library
Ion Chromatography of Soluble Cr(III) and Cr(VI) (open access)

Ion Chromatography of Soluble Cr(III) and Cr(VI)

Ion chromatography coupled with a conductivity detector was used to investigate the analysis of Cr(III) and Cr(VI) in aqueous samples. An IC methodology for Cr(III) was developed using a cation column and an eluent containing tartaric acid, ethylenediamine, and acetonitrile at pH 2.9. The detection limit of this method can reach 0.1 ppm level with good precision. Several operational parameters were evaluated during the regular use of the method. Comparison of the IC method with AA method showed good agreement between the two methods. The anion exchange column was used for Cr(VI) determination. The best results were obtained with an eluent containing sodium gluconate, borate buffer, glycerin, and acetonitrile. The retention time for the Cr207 2 - sample was 11 min. and the calibration curve was linear between 1.0 and 100 ppm.
Date: August 1988
Creator: Huang, Julie Shiong-Jiun
System: The UNT Digital Library
Detector Comparison for Simultaneous Determination of Organic Acids and Inorganic Anions (open access)

Detector Comparison for Simultaneous Determination of Organic Acids and Inorganic Anions

The research reported here is a study of detector systems to determine those most suited for simultaneous organic acid, inorganic anion determination. Comparisons are made on the basis of detection limits and sensitivities for conductivity, UV/Vis, photoconductivity, and derivative conductivity detection systems. The investigation was made using a constant chromatographic system with the only variable component being the detector system. Eluant optimization conditions for each detector are reported along with tables reporting detection limits and sensitivities for each detector system. Various chromatograms are also shown to provide a visual comparison between detector results.
Date: August 1988
Creator: Pannell, Daniel K. (Daniel Kirk)
System: The UNT Digital Library
A Reinvestigation of the Kinetics and Mechanism of Ligand Exchange in Mu-(2,2,8,8-Tetramethyl-3, 7-Dithianonane)-Decacarbonylditungsten(0) (open access)

A Reinvestigation of the Kinetics and Mechanism of Ligand Exchange in Mu-(2,2,8,8-Tetramethyl-3, 7-Dithianonane)-Decacarbonylditungsten(0)

This student is interested in reinvestigating the kinetics and mechanism of the bridged compound in l,2-dichloroethane with triisopropyl phosphite and in finding the reasons why the values of competition ratio k₋₂ /k₃ in this reaction are so large.
Date: August 1988
Creator: Liao, Jing-Piin
System: The UNT Digital Library