275,965 Matching Results

Results open in a new window/tab.

10 (micro)m and 5 (micro)m Pinhole-Assisted Point-Projection Backlit Imaging for NIF (open access)

10 (micro)m and 5 (micro)m Pinhole-Assisted Point-Projection Backlit Imaging for NIF

Pinhole-assisted point-projection backlighting with 10{micro}m and 5 {micro}m pinholes placed a small distance of order 1 mm away from the backlighter produces images with large field of view and high resolution. Pinholes placed closely to high-power backlighter sources can vaporize and close due to x-ray driven ablation, thereby limiting the usefulness of this method. A study of streaked 1-D backlit imaging of 25 {micro}m W wires using the OMEGA laser is presented. The pinhole closure timescale for 10 {micro}m pinholes placed 0.45 mm and 1 mm distant from the backlighter is 1.3 ns and 2.2 ns, respectively. Similar timescales for 5 {micro}m pinholes is also presented. Successful wire imaging prior to pinhole closure is clearly demonstrated.
Date: June 5, 2001
Creator: Bullock, A. B.; Landen, O. L. & Bradley, D. K.
Object Type: Article
System: The UNT Digital Library
10 microsecond time resolution studies of Cygnus X-1 (open access)

10 microsecond time resolution studies of Cygnus X-1

Time variability analyses have been applied to data composed of event times of X-rays emitted from the binary system Cygnus X-1 to search for unique black hole signatures. The X-ray data analyzed was collected at ten microsecond time resolution or better from two instruments, the High Energy Astrophysical Observatory (HEAO) A-1 detector and the Rossi X-ray Timing Explorer (XTE) Proportional Counter Array (PCA). HEAO A-1 and RXTE/PCA collected data from 1977--79 and from 1996 on with energy sensitivity from 1--25 keV and 2--60 keV, respectively. Variability characteristics predicted by various models of an accretion disk around a black hole have been searched for in the data. Drop-offs or quasi-periodic oscillations (QPOs) in the Fourier power spectra are expected from some of these models. The Fourier spectral technique was applied to the HEAO A-1 and RXTE/PCA data with careful consideration given for correcting the Poisson noise floor for instrumental effects. Evidence for a drop-off may be interpreted from the faster fall off in variability at frequencies greater than the observed breaks. Both breaks occur within the range of Keplerian frequencies associated with the inner edge radii of advection-dominated accretion disks predicted for Cyg X-1. The break between 10--20 Hz is also …
Date: June 1, 1997
Creator: Wen, H.C.
Object Type: Thesis or Dissertation
System: The UNT Digital Library
10-MWe pilot-plant-receiver-panel test-requirements document: Solar Thermal Test Facility (open access)

10-MWe pilot-plant-receiver-panel test-requirements document: Solar Thermal Test Facility

Plans are presented for insolation testing of a full-scale test receiver panel and supporting hardware which essentially duplicate both physically and functionally the design planned for the 10 MWe pilot plant. Testing includes operation during normal start and shutdown, intermittent cloud conditions, and emergencies to determine the transient and steady state operating characteristics and performance under conditions equal to or exceeding those expected in the pilot plant. The effects of variations of input and output conditions on receiver operation are also to be investigated. A brief description of the pilot plant receiver subsystem is presented, followed by a detailed description of the receiver assembly to be tested at the Solar Thermal Test Facility. Major subassemblies are described, including the receiver panel, flow control, electrical control and instrumentation, and the structural assembly. Requirements of the Solar Thermal Test Facility for the tests are given. System safety measures are described. The tests, operating conditions, and expected results are presented. Quality assurance, task responsibilities, and test documentation are also discussed. (LEW)
Date: June 10, 1978
Creator: unknown
Object Type: Report
System: The UNT Digital Library

10 Pierce rigs (6-16-2017)

None
Date: June 16, 2017
Creator: unknown
Object Type: Photograph
System: The Gateway to Oklahoma History
10 Questions: About Pregnancy and HIV (open access)

10 Questions: About Pregnancy and HIV

This pamphlet provides information on why pregnant women need to get tested for HIV.
Date: June 2011
Creator: Texas Consortium for Perinatal HIV Prevention
Object Type: Pamphlet
System: The Portal to Texas History
14-plex Feasibility Report (open access)

14-plex Feasibility Report

The Native Village of Unalakleet project was a feasibility study for a retrofit of a “tribally owned” three story, 14 apartment complex located in Unalakleet, Alaska. The program objective and overall goal was to create a plan for retrofitting to include current appraised value and comparable costs of new construction to determine genuine feasibility as low-income multi-family housing for tribal members.
Date: June 21, 2013
Creator: Kotongan, Victoria Hazel
Object Type: Report
System: The UNT Digital Library
A 15-T Pulsed Solenoid for a High-Power Target Experiment (open access)

A 15-T Pulsed Solenoid for a High-Power Target Experiment

The MERIT experiment, which ran at CERN in 2007, is a proof-of-principle test for a target system that converts a 4-MW proton beam into a high-intensity muon beam for either a neutrino factory complex or a muon collider. The target system is based on a free mercury jet that intercepts an intense proton beam inside a 15-T solenoidal magnetic field. Here, we describe the design and performance of the 15-T, liquid-nitrogen-precooled, copper solenoid magnet.
Date: June 23, 2008
Creator: Kirk, H. G.; Efthymiopoulos, I.; Fabich, A.; Haug, F.; Pereira, H.; Titus, P. et al.
Object Type: Article
System: The UNT Digital Library
A 15-T Pulsed Solenoid for a High-Power Target Experiment (open access)

A 15-T Pulsed Solenoid for a High-Power Target Experiment

The MERIT experiment, to be run at CERN in 2007, is a proof-of-principle test for a target system that converts a 4-MW proton beam into a high-intensity muon beam for either a neutrino factory complex or a muon collider. The target system is based on a free mercury jet that intercepts an intense proton beam inside a 15-T solenoidal magnetic field. Here, we describe the design and initial performance of the 15-T, liquid-nitrogen-precooled, copper solenoid magnet.
Date: June 26, 2006
Creator: Kirk, H. G.; Efthymiopoulos, I.; Fabich, A.; Haug, R.; Titus, P.; McDonald, K. T. et al.
Object Type: Article
System: The UNT Digital Library

17 East Grand

Photograph of a man carrying suitcases in front of 17 East Grand in Oklahoma City.
Date: June 1956
Creator: Meyers Photo Shop
Object Type: Photograph
System: The Gateway to Oklahoma History

17" x 14" Horizontal Engine Link Motion No. 13 Steam Vertical Windlass

Blueprint depicting technical details of Battleship Texas.
Date: June 9, 1909
Creator: unknown
Object Type: Technical Drawing
System: The Portal to Texas History
[20 year anniversary of the Dallas Gay and Lesbian Alliance invitation] (open access)

[20 year anniversary of the Dallas Gay and Lesbian Alliance invitation]

An invitation for the Presidents' Reception during the 20th year anniversary of the Dallas Gay and Lesbian Alliance.
Date: June 6, 1997
Creator: unknown
Object Type: Text
System: The UNT Digital Library
A 20-year data set of surface longwave fluxes in the Arctic (open access)

A 20-year data set of surface longwave fluxes in the Arctic

Creation of 20-year data set of surface infrared fluxes from satellite measurements. A reliable estimate of the surface downwelling longwave radiation flux (DLF) is a glaring void in available forcing data sets for models of Arctic sea ice and ocean circulation. We have developed a new method to estimate the DLF from a combination of satellite sounder retrievals and brightness temperatures from the TIROS Operational Vertical Sounder (TOVS), which has flown on NOAA polar-orbiting satellites continuously since late 1979. The overarching goal of this project was to generate a 20-year data set of surface downwelling longwave flux measurements from TOVS data over the Arctic Ocean. Daily gridded fields of DLF were produced with a spatial resolution of (100 km){sup 2} north of 60{sup o}N for 22.5 years rather than only 20. Surface measurements from the field station at Barrow, AK--part of the Atmospheric Radiation Measurement (ARM) Program --and from the Surface Heat Budget of the Arctic (SHEBA) were used to validate the satellite-derived fluxes and develop algorithm improvements for conditions that had resulted in systematic errors in early versions of the algorithm. The resulting data set has already been sent to two other investigators for incorporation into their research, and …
Date: June 15, 2004
Creator: Francis, Jennifer
Object Type: Report
System: The UNT Digital Library
21 Jun 05 Memo from DoD Transmitting Draft Copies of DoD Strategy for Homeland Defense & Civil Support to Commission (open access)

21 Jun 05 Memo from DoD Transmitting Draft Copies of DoD Strategy for Homeland Defense & Civil Support to Commission

Memo from Deputy Under Secretary of Defense (Installations and Environment) Phil Grone to Frank Cirillo (Director, Review and Analysis) Transmitting Draft Copies of DoD Strategy for Homeland Defense & Civil Support to Commission
Date: June 21, 2005
Creator: United States. Department of Defense.
Object Type: Text
System: The UNT Digital Library
24-Channel Geophone Array for Horizontal or Vertical Boreholes Quarterly Technical Report: January-March 2003 (open access)

24-Channel Geophone Array for Horizontal or Vertical Boreholes Quarterly Technical Report: January-March 2003

This report describes the technical progress on a project to design and construct a multichannel geophone array that improves tomographic imaging capabilities in both surface and underground mines. Especially important in the design of the array is sensor placement. One issue related to sensor placement is addressed in this report: the method for clamping the sensor once it is emplaced in the borehole. If the sensors (geophones) are not adequately coupled to the surrounding rock mass, the resulting data will be of very poor quality. Improved imaging capabilities will produce energy, environmental, and economic benefits by increasing exploration accuracy and reducing operating costs.
Date: June 1, 2003
Creator: Westman, Erik C.
Object Type: Report
System: The UNT Digital Library

24" Searchlight Platform on Mainmast

Blueprint depicting technical details of Battleship Texas.
Date: June 15, 1943
Creator: unknown
Object Type: Technical Drawing
System: The Portal to Texas History

30 gallon water heater

Blueprint depicting technical details of Battleship Texas.
Date: June 2, 1941
Creator: unknown
Object Type: Technical Drawing
System: The Portal to Texas History
A 30 MW, 200 MHz Inductive Output Tube for RF Accelerators (open access)

A 30 MW, 200 MHz Inductive Output Tube for RF Accelerators

This program investigated development of a multiple beam inductive output tube (IOT) to produce 30 MW pulses at 200 MHz. The program was successful in demonstrating feasibility of developing the source to achieve the desired power in microsecond pulses with 70% efficiency. The predicted gain of the device is 24 dB. Consequently, a 200 kW driver would be required for the RF input. Estimated cost of this driver is approximately $1.25 M. Given the estimated development cost of the IOT of approximately $750K and the requirements for a test set that would significantly increase the cost, it was determined that development could not be achieved within the funding constraints of a Phase II program.
Date: June 19, 2008
Creator: Ives, R. Lawrence & Read, Michael
Object Type: Report
System: The UNT Digital Library

36" x 18" Door for Forced Lubrication Casing - Main Engine

Blueprint depicting technical details of Battleship Texas.
Date: June 25, 1913
Creator: unknown
Object Type: Technical Drawing
System: The Portal to Texas History

40 MM Quad. Gun Foundations 26" Forward Frame 52 P/S on Signal Bridge

Blueprint depicting technical details of Battleship Texas.
Date: June 1, 1943
Creator: unknown
Object Type: Technical Drawing
System: The Portal to Texas History

40 MM Quad. Gun Foundations 26" Forward Frame 52 P/S on Signal Bridge

Blueprint depicting technical details of Battleship Texas.
Date: June 1, 1943
Creator: unknown
Object Type: Technical Drawing
System: The Portal to Texas History
45-day safety screen results and final report for tank 241-C-202, auger samples 95-Aug-026 and 95-Aug-027 (open access)

45-day safety screen results and final report for tank 241-C-202, auger samples 95-Aug-026 and 95-Aug-027

Two auger samples from tank 241-C-202 (C-202) were received at the 222-S Laboratories and underwent safety screening analysis, consisting of differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha activity. Two samples were submitted for energetics determination by DSC. Within the triplicate analyses of each sample, one of the results for energetics exceeded the notification limit. The sample and duplicate analyses for both augers exceeded the notification limit for TGA. As required by the Tank Characterization Plan, the appropriate notifications were made within 24 hours of official confirmation that the limits were violated.
Date: June 19, 1995
Creator: Baldwin, J.H.
Object Type: Report
System: The UNT Digital Library
45-Day safety screen results and final report for Tank 241-SX-113, Auger samples 94-AUG-028 and 95-AUG-029 (open access)

45-Day safety screen results and final report for Tank 241-SX-113, Auger samples 94-AUG-028 and 95-AUG-029

This document serves as the 45-day report deliverable for tank 241-SX-113 auger samples collected on May 9 and 10, 1995. The samples were extruded, and analyzed by the 222-S Laboratory. Laboratory procedures completed include: differential scanning calorimetry; thermogravimetric analysis; and total alpha analysis. This report incudes the primary safety screening results obtained from the analyses. As the final report, the following are also included: chains of custody; the extrusion logbook; sample preparation data; and total alpha analysis raw data.
Date: June 22, 1995
Creator: Sasaki, L.M.
Object Type: Report
System: The UNT Digital Library
45-Day safety screen results for Tank 241-C-201, Auger samples 95-AUG-025 and 95-AUG-026 (open access)

45-Day safety screen results for Tank 241-C-201, Auger samples 95-AUG-025 and 95-AUG-026

Two auger samples from tank 241-C-201 (C-201) were received by the 222-S Laboratories and underwent safety screening analysis, consisting of differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha activity. Analytical results for the DSC analyses of both samples exceeded the notification limit of 481 J/g (dry weight basis). As well, the TGA analyses for both samples were less than the safety screening notification limit (notification is made if the sample is analyzed at less than 17 percent water). Notification of both of these occurrences was made on May,15, 1995, and secondary analysis of total organic carbon (TOC) was initiated. These TOC analysis results are also included in this report.
Date: June 15, 1995
Creator: Schreiber, R. D.
Object Type: Report
System: The UNT Digital Library
45-Day safety screening results for tank 241-U-102, push mode cores 143 and 144 (open access)

45-Day safety screening results for tank 241-U-102, push mode cores 143 and 144

This document is the 45-day report deliverable for tank 241-U-102 push mode core segments collected between April 16, 1996 and May 6, 1996 and received by the 222-S Laboratory between April 17, 1996 and May 8, 1996. The segments were subsampled and analyzed in accordance, with the Tank 241-U-102 Push Mode Core Sampling and analysis Plan (TSAP) (Hu, 1996) and the Safety Screening Data Quality Objective (DQO) (Dukelow, et al., 1995). The analytical results are included in Table 1. Attachment I is a cross reference to relate the tank farm identification numbers to the 222-S Laboratory LabCore sample numbers. The subsamples generated in the laboratory for analysis are identified in these diagrams with their sources shown. The diagram identifying the hydrostatic head fluid (HHF) blank is also included, Primary safety screening results and the raw data from Differential Scanning Calorimetry (DSC) and thermogravimetric analysis (TGA) analyses are included in this report. Two of the samples submitted for DSC analysis exceeded notification limits as stated in the Safety Screening DQO (Dukelow, et al., 1995). Cyanide analysis was requested on these samples and a Reactive System Screening Tool analysis was requested for the sample exhibiting the highest exothenn in accordance with the …
Date: June 28, 1996
Creator: Steen, F. H.
Object Type: Report
System: The UNT Digital Library