Data validation summary report: 300-FF-5 operable unit; Round 6 groundwater (open access)

Data validation summary report: 300-FF-5 operable unit; Round 6 groundwater

Laboratory data for Sixth Round Groundwater samples collected during the 300-FF-5 Operable Unit Remedial Investigation have been reviewed and validated to ensure that they are of sufficient quality to support decisions regarding further actions to be taken at the 300-FF-5 Operable Unit. Table 1-1 is a summary of the validated samples. This report summarizes the results previously presented to Westinghouse Hanford in a series of Preliminary Quality Assurance Reports (PQAR) for the 300-FF-5 Sixth Round Groundwater samples. In some instances, the data qualifiers originally presented in the PQARs have been changed based upon further review of the data; these changes are highlighted in the text.
Date: March 21, 1994
Creator: Hulstrom, L. C.
Object Type: Report
System: The UNT Digital Library
Evaluation of melter system technologies for vitrification of high-sodium content low-level radioactive liquid wastes (open access)

Evaluation of melter system technologies for vitrification of high-sodium content low-level radioactive liquid wastes

Westinghouse Hanford Company (WHC) is conducting a two-phased demonstration testing and evaluation of candidate melter system technologies for vitrification of Hanford Site low-level tank wastes. The testing is to be performed by melter equipment and vitrification technology commercial suppliers. This Statement of Work is for Phases 1 and 2 of the demonstration testing program. The primary objective of the demonstration testing is to identify the best available melter system technology for the Hanford Site LLW vitrification facility. Data obtained also will support various WHC engineering studies and conceptual design of the LLW vitrification facility. Multiple technologies will be selected for demonstration and evaluation. Testing will be conducted using non-radioactive LLW simulants in Seller-specified pilot/testing facilities.
Date: March 21, 1994
Creator: Wilson, C. N.
Object Type: Report
System: The UNT Digital Library
Potential worker risk as a function of CAM airflow rate (open access)

Potential worker risk as a function of CAM airflow rate

The goal of the continuous air monitor (CAM) system at the Los Alamos National Laboratory`s Plutonium Facility (PF-4) is to have a flow rate of 1 cubic feet per minute (cfm) drawn through the CAMs. However, design limitations in the house vacuum result in many CAMs having less than 1 cfm being drawn through them. Reduced flow rates through CAMs present a compromise in worker protection. Laboratory Health and Safety personnel and DOE officials established a flow rate of 0.5 cfm or less as operationally unacceptable. This report quantitatively estimated the difference in risk to workers from a reduced flow rate of 0.5 cfm relative to the risk inherent with a flow rate of 1 cfm. I calculated risk in terms of Committed Effective Dose Equivalent (CEDE) and used units of rem. Estimates for the increase in risk for 0.5 cfm compared to 1 cfm ranged from 0.32 rem to 3.3 rem. The difference in the minimum alarm concentration between 0.5 cfm and I cfm was also compared and was estimated to range from 0.4 rem to 4 rem.
Date: March 21, 1994
Creator: Whicker, J. J.
Object Type: Article
System: The UNT Digital Library
Ambulatory Research and Education Center Oregon Health Science University. Environmental Assesment (open access)

Ambulatory Research and Education Center Oregon Health Science University. Environmental Assesment

DOE has prepared an Environmental Assessment (EA) (DOE/EA-0921) evaluating the proposed construction and operation of the Ambulatory Research and Education Center (AREC), which would be located on the top seven floors of the existing NeuroSensory Research Center (NRC) on the campus of the Oregon Health Sciences University (OHSU) at Portland, Oregon. The proposed action would combine activities scattered across the campus into a central facility. Based on the analysis in the EA, DOE has determined that the proposed action does not constitute a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) of 1969, 42 USC 4321 et seq. Therefore, an environmental impact statement (EIS) is not required and the Department is issuing this Finding of No Significant Impact (FONSI).
Date: March 21, 1994
Creator: unknown
Object Type: Report
System: The UNT Digital Library
Advanced conceptual design report solid waste retrieval facility, phase I, project W-113 (open access)

Advanced conceptual design report solid waste retrieval facility, phase I, project W-113

Project W-113 will provide the equipment and facilities necessary to retrieve suspect transuranic (TRU) waste from Trench 04 of the 218W-4C burial ground. As part of the retrieval process, waste drums will be assayed, overpacked, vented, head-gas sampled, and x-rayed prior to shipment to the Phase V storage facility in preparation for receipt at the Waste Receiving and Processing Facility (WRAP). Advanced Conceptual Design (ACD) studies focused on project items warranting further definition prior to Title I design and areas where the potential for cost savings existed. This ACD Report documents the studies performed during FY93 to optimize the equipment and facilities provided in relation to other SWOC facilities and to provide additional design information for Definitive Design.
Date: March 21, 1994
Creator: Smith, K. E.
Object Type: Report
System: The UNT Digital Library