Increasing Effective Thermal Resistance of Building Envelope's Insulation Using Polyurethane Foam Incorporated with Phase Change Material (open access)

Increasing Effective Thermal Resistance of Building Envelope's Insulation Using Polyurethane Foam Incorporated with Phase Change Material

Incorporating insulation material with phase change materials (PCMs) could help enhance the insulation capability for further building energy savings by reducing the HVAC loadings. During the phase change process between the solid and liquid states, heat is being absorbed or released by PCMs depending on the surrounding temperature. This research explores the benefits of a polyurethane (PU)-PCM composite insulation material through infiltrating paraffin wax as PCM into PU open cell foam. The new PU-PCM composite provides extra shielding from the exterior hot temperatures for buildings. Through this study, it was demonstrated that PU-PCM composite insulation could potentially help building energy savings through reducing the loads on the HVAC systems based on the building energy modeling using EnergyPlus. The Zero Energy Lab (ZØE) at the University of North Texas was modeled and studied in the EnergyPlus. It is a detached building with all wall facades exposed to the ambient. It was determined that the new PU-PCM insulation material could provide 14% total energy saving per year and reduce the electricity use due to cooling only by around 30%.
Date: May 2019
Creator: Houl, Yassine
System: The UNT Digital Library
Use of Bio-Product/Phase Change Material Composite in the Building Envelope for Building Thermal Control and Energy Savings (open access)

Use of Bio-Product/Phase Change Material Composite in the Building Envelope for Building Thermal Control and Energy Savings

This research investigates the bio-products/phase change material (PCM) composites for the building envelope application. Bio-products, such as wood and herb, are porous medium, which can be applied in the building envelope for thermal insulation purpose. PCM is infiltrated into the bio-product (porous medium) to form a composite material. The PCM can absorb/release large amount of latent heat of fusion from/to the building environment during the melting/solidification process. Hence, the PCM-based composite material in the building envelope can efficiently adjust the building interior temperature by utilizing the phase change process, which improves the thermal insulation, and therefore, reduces the load on the HVAC system. Paraffin wax was considered as the PCM in the current studies. The building energy savings were investigated by comparing the composite building envelope material with the conventional material in a unique Zero-Energy (ZØE) Research Lab building at University of North Texas (UNT) through building energy simulation programs (i.e., eQUEST and EnergyPlus). The exact climatic conditions of the local area (Denton, Texas) were used as the input values in the simulations. It was found that the EnergyPlus building simulation program was more suitable for the PCM based building envelope using the latent heat property. Therefore, based on the …
Date: August 2018
Creator: Boozula, Aravind Reddy
System: The UNT Digital Library
Field Validation of Zero Energy Lab Water-to-Water Ground Coupled Heat Pump Model (open access)

Field Validation of Zero Energy Lab Water-to-Water Ground Coupled Heat Pump Model

Heat pumps are a vital part of each building for their role in keeping the space conditioned for the occupant. This study focuses on developing a model for the ground-source heat pump at the Zero Energy lab at the University of North Texas, and finding the minimum data required for generating the model. The literature includes many models with different approaches to determine the performance of the heat pump. Each method has its pros and cons. In this research the equation-fit method was used to generate a model based on the data collected from the field. Two experiments were conducted for the cooling mode: the first one at the beginning of the season and the second one at the peak of the season to cover all the operation conditions. The same procedure was followed for the heating mode. The models generated based on the collected data were validated against the experiment data. The error of the models was within ±10%. The study showed that the error could be reduced by 20% to 42% when using the field data to generate the model instead of the manufacturer’s catalog data. Also it was found that the minimum period to generate the cooling …
Date: May 2016
Creator: Abdulameer, Saif
System: The UNT Digital Library
Ozone Pollution of Shale Gas Activities in North Texas (open access)

Ozone Pollution of Shale Gas Activities in North Texas

The effect of shale gas activities on ground-level ozone pollution in the Dallas-Fort Worth area is studied in detail here. Ozone is a highly reactive species with harmful effects on human and environment. Shale gas development, or fracking, involves activities such as hydraulic fracturing, drilling, fluid mixing, and trucks idling that are sources of nitrogen oxides (NOX) and volatile organic compounds (VOC), two of the most important precursors of ozone. In this study two independent approaches have been applied in evaluating the influences on ozone concentrations. In the first approach, the influence of meteorology were removed from ozone time series through the application of Kolmogorov-Zurbenko low-pass filter, logarithmic transformation, and subsequent multi-linear regression. Ozone measurement data were acquired from Texas Commission on Environmental Quality (TCEQ) monitoring stations for 14 years. The comparison between ozone trends in non-shale gas region and shale gas region shows increasing ozone trends at the monitoring stations in close proximity to the Barnett Shale activities. In the second approach, the CAMx photochemical model was used to assess the sensitivity of ozone to the NOX and VOC sources associated with shale oil and gas activities. Brute force method was applied on Barnett Shale and Haynesville Shale emission …
Date: May 2016
Creator: Ahmadi, Mahdi
System: The UNT Digital Library
Performance Evaluation of UNT Apogee Stadium Wind Turbines (open access)

Performance Evaluation of UNT Apogee Stadium Wind Turbines

The following report chronicles the University of North Texas Wind Turbine Project at Apogee Stadium. The timeline of events will include the feasibility study conducted by and for the university, grant awards from the Texas State Energy Conservation Office to fund the project, and a three-year sample of real time performance data since installation. The purpose of this case study is to compare the energy generation estimates by various stakeholders to the measured energy generation using a new but uniform performance relationship. In order to optimize energy generation in wind turbine generator systems, the most common wind speeds measured at the site should also be the most efficient wind speeds at which the wind turbine can convert the kinetic energy in the wind into mechanical energy and ultimately electrical energy. The tool used to convey this relationship will be a figure plotting the wind speed profile against the efficiency curve of the wind turbine. Applying this relationship tool to the UNT Apogee Stadium wind turbines provided valuable results. The most common wind speeds at Apogee Stadium are not the most efficient wind speed for the turbine. Also, the most common wind speeds were near the lower limit of the wind …
Date: May 2016
Creator: McCary, William D., III
System: The UNT Digital Library
A study of the impact of unconventional sources within a large urban area: evidence from spatio-temporal assessment of volatile organic compounds. (open access)

A study of the impact of unconventional sources within a large urban area: evidence from spatio-temporal assessment of volatile organic compounds.

Conventional sources of emissions have been a prime target for policymakers in designing pollution control strategies. However, the evolution of shale gas activities is a growing concern over the impact of unconventional sources on urban and regional air quality. Owing to the development of Barnett Shale production, the fast-growing Dallas-Fort Worth (DFW) metroplex has encountered both types of these emissions. Oil and gas activities result in emissions of ozone precursors, notably volatile organic compounds (VOC). The major objective of this study was to evaluate the spatio-temporal distribution of VOC in order to highlight the influence of unconventional emissions. The study utilized measurements from automated gas chromatography (AutoGC) monitors to analyze the patterns of the total non-methane organic compounds (TNMOC) and relative contributions from marker species of traffic versus oil and gas activities. In this study, data from 2001-2014 was obtained from the Texas Commission on Environmental Quality (TCEQ) for fifteen monitoring sites within the North Texas region. With over a thousand wells in a 10 mile radius, two of the rural sites measured twice as much TNMOC as compared to the urban site in Dallas. Source apportionment analysis was conducted using Positive Matrix Factorization (PMF) technique. The target site located …
Date: May 2016
Creator: Matin, Maleeha
System: The UNT Digital Library
Evaluation of the Influence of Non-Conventional Sources of Emissions on Ambient Air Pollutant Concentrations in North Texas (open access)

Evaluation of the Influence of Non-Conventional Sources of Emissions on Ambient Air Pollutant Concentrations in North Texas

Emissions of air pollutants from non-conventional sources have been on the rise in the North Texas area over the past decade. These include primary pollutants such as volatile organic compound (VOC) and oxides of nitrogen (NOx) which also act as precursors in the formation of ozone. Most of these have been attributed to a significant increase in oil and gas production activities since 2000 within the Barnett Shale region adjacent to the Dallas-Fort Worth metroplex region. In this study, air quality concentrations measured at the Denton Airport and Dallas Hinton monitoring sites operated by the Texas Commission on Environmental Quality (TCEQ) were evaluated. VOC concentration data from canister-based sampling along with continuous measurement of oxides of nitrogen (NOx), ozone (O3), particulate matter (PM2.5), and meteorological conditions at these two sites spanning from 2000 through 2014 were employed in this study. The Dallas site is located within the urban core of one of the fastest growing cities in the United States, while the Denton site is an exurban site with rural characteristics to it. The Denton Airport site was influenced by natural gas pads surrounding it while there are very few natural gas production facilities within close proximity to the Dallas …
Date: August 2015
Creator: Lim, Guo Quan
System: The UNT Digital Library
Estimation of Air Emissions During Production Phase from Active Oil and Gas Wells in the Barnett Shale Basin: 2010-2013 (open access)

Estimation of Air Emissions During Production Phase from Active Oil and Gas Wells in the Barnett Shale Basin: 2010-2013

The Barnett shale basin, the largest onshore gas field in the state of Texas, mainly produces natural gas. The basin’s oil and gas productions have dramatically increased over the past two decades with the enhancement via shale fracturing (fracking) technology. However, recent studies suggest that air emissions from shale fracking have significantly contributed to the growing air pollution problem in North Texas. In this study, air emissions from the Barnett shale basin during the production phase of the oil and gas activities (once the product is collected from the wells) are quantified. Oil and gas production data were acquired from the Texas Railroad Commission for the baseline years of 2010 through 2013. Methodology from prior studies on shale basins approved by the Texas Commission on Environmental Quality was employed in this study and the emission inventories from the production phase sources were quantified. Accordingly, the counties with the most gas operations in the basin, Tarrant, Johnson, Denton and Wise, were found to be the highest emitters of air pollutants. Tarrant County was responsible for the highest emitted NOx (42,566 tons) and CO (17,698 tons) in the basin, while Montague County released the maximum VOC emissions (87,601 tons) during the study …
Date: May 2015
Creator: Dohde, Farhan A.
System: The UNT Digital Library