The Detection of Small Amounts of Fluorine in Large Amounts of Chlorine (open access)

The Detection of Small Amounts of Fluorine in Large Amounts of Chlorine

Abstract: "Tests have been developed for both the qualitative detection and quantitative determination of fluorine in chlorine. The qualitative test is made by passing the gas through manganous chloride. If the pink solid tubes brown there is greater than 0.5 percent of fluorine in the gas. The quantitative test is a modification of the Steiger and Marvin Test with oxidized titanium solution."
Date: April 1, 1946
Creator: Lafferty, Robert H., Jr. & Winget, Rasho
System: The UNT Digital Library
A Mathematical Analysis of the Calutron (open access)

A Mathematical Analysis of the Calutron

Abstract: "The definitions of the fundamental measures of calutron operation including enhancement, current ratio, and process efficiency are set forth with derivations of the relationships between them. An analysis of the plant process is carried out for both the tanks limited and the charge limited case. Equations are derived for plant X output and plant X utilization efficiency. Effective production is defined and the value of increment to a mass of product material in terms of effective production is determined. An equation giving the X concentration below which product material should be reprocessed is derived."
Date: April 12, 1946
Creator: Leith, C. E.
System: The UNT Digital Library
Ohmic Characteristics of High Megohm Resistors (open access)

Ohmic Characteristics of High Megohm Resistors

The following report discusses ohmic characteristics in resistors, including methods for determining the polarization characteristics of high megohm resistors that may determine the suitability of these resistors for spectrometric measurements.
Date: April 3, 1946
Creator: Cameron, Angus Ewan, 1906- & White, J. R.
System: The UNT Digital Library
The Detection of Uranium by X-ray Spectrometry (open access)

The Detection of Uranium by X-ray Spectrometry

Abstract: "The possibility of detecting small quantities of uranium with an X-ray spectrometer was investigated. An X-ray spectrograph was modified by substituting a geiger counter for the photographic film. Both primary and secondary methods of excitation were studied. Radiation background of high intensity and variability limits the sensitivity of the present apparatus to 1%. Suggestions are made for increasing the sensitivity of the method."
Date: April 9, 1946
Creator: Saunders, B. G.; Burkhart, L. E. & Larson, C. E.
System: The UNT Digital Library