Xenon and Samarium Poisoning (open access)

Xenon and Samarium Poisoning

The equilibrium and maximum override values for xenon and samarium poisoning have been computed using the recently issued effective cross sections of C. H. Westcott. Values are given as a function of specific power, neutron temperature, and epithermal flux content.
Date: January 23, 1961
Creator: Carlsmith, R. S.
System: The UNT Digital Library
Eddy-Current Measurement of Clad Thickness on Mark X MTR Fuel Plates (open access)

Eddy-Current Measurement of Clad Thickness on Mark X MTR Fuel Plates

At the request of the Alloy Preparation Group, the Nondestructive Test Development Group investigated the feasibility of determining the clad thickness on Mark X MTR Fuel Plates. As the use of induced eddy-currents was considered to be the most promising approach, a prototype instrument and probe coil utilizing this principle was developed to measure clad thickness. The results of the investigation conducted with this instrument indicate that the clad thickness of this type of fuel plats can be measured to withing +- 0.001 in.
Date: January 23, 1957
Creator: Oliver, R. B.; Allen, J. W. & Nance, Roy A.
System: The UNT Digital Library