Full scale field test of the in situ air stripping process at the Savannah River integrated demonstration test site (open access)

Full scale field test of the in situ air stripping process at the Savannah River integrated demonstration test site

Under sponsorship from the US Department of Energy, technical personnel from the Savannah River Laboratory (SRL) and other DOE laboratories, universities and private industry have completed a full scale demonstration of environmental remediation using horizontal wells. This demonstration was performed as Phase I of an Integrated Demonstration Project designed to evaluate innovative remediation technologies for environmental restoration of sites contaminated with organic contaminants. The demonstration utilized two directionally drilled horizontal wells to deliver gases and extract contaminants from the subsurface. The resulting in situ air stripping process was designed to remediate soils and sediments above and below the water table as well as groundwater contaminated with volatile organic contaminants. The 139 day long test successfully removed volatile chlorinated solvents from the subsurface using the two horizontal wells. One well, approximately 300 ft (90m) long and 165 ft (50m) deep drilled below a contaminant plume in the groundwater, was used to inject air and strip the contaminants from the groundwater. A second horizontal well, approximately 175 ft (53m) long and 75 ft (23m) deep in the vadose zone, was used to extract residual contamination in the vadose zone along with the material purged from the groundwater. Pretest and posttest characterization data …
Date: June 29, 1991
Creator: Looney, B. B.; Hazen, T. C.; Kaback, D. S. & Eddy, C. A.
System: The UNT Digital Library
Calculations of bottom quark production at hadron colliders (open access)

Calculations of bottom quark production at hadron colliders

This thesis studies Monte Carlo simulations of QCD heavy flavor production processes (p{bar p} {yields} Q({anti Q})X) at hadron colliders. ISAJET bottom quark cross-sections are compared to the O({alpha} {sub s}{sup 3}) perturbative calculation of Nason, Dawson, and Ellis. These Monte Carlo cross-sections are computed from data samples which use different parton distribution functions and physics parameters. Distributions are presented in the heavy quark's transverse momentum and rapidity. Correlations in rapidity and azimuthal angle are computed for the heavy flavor pair. Theory issues which arise are the behavior of the cross-section at low and high values of transverse momentum and the treatment of double counting problems in the flavor excitation samples. An important result is that ISAJET overestimates bottom quark production cross-sections and K factors. These findings are relevant for estimates of rates and backgrounds of heavy floor events.
Date: June 29, 1991
Creator: Kuebel, D.
System: The UNT Digital Library
Full scale field test of the in situ air stripping process at the Savannah River integrated demonstration test site (open access)

Full scale field test of the in situ air stripping process at the Savannah River integrated demonstration test site

Under sponsorship from the US Department of Energy, technical personnel from the Savannah River Laboratory (SRL) and other DOE laboratories, universities and private industry have completed a full scale demonstration of environmental remediation using horizontal wells. This demonstration was performed as Phase I of an Integrated Demonstration Project designed to evaluate innovative remediation technologies for environmental restoration of sites contaminated with organic contaminants. The demonstration utilized two directionally drilled horizontal wells to deliver gases and extract contaminants from the subsurface. The resulting in situ air stripping process was designed to remediate soils and sediments above and below the water table as well as groundwater contaminated with volatile organic contaminants. The 139 day long test successfully removed volatile chlorinated solvents from the subsurface using the two horizontal wells. One well, approximately 300 ft (90m) long and 165 ft (50m) deep drilled below a contaminant plume in the groundwater, was used to inject air and strip the contaminants from the groundwater. A second horizontal well, approximately 175 ft (53m) long and 75 ft (23m) deep in the vadose zone, was used to extract residual contamination in the vadose zone along with the material purged from the groundwater. Pretest and posttest characterization data …
Date: June 29, 1991
Creator: Looney, B. B.; Hazen, T. C.; Kaback, D. S. & Eddy, C. A.
System: The UNT Digital Library