5/10-MVA high temperature superconducting power transformer. Progress report for the period May 1998 - June 1999 (open access)

5/10-MVA high temperature superconducting power transformer. Progress report for the period May 1998 - June 1999

None
Date: July 28, 1999
Creator: Intermagnetics General Corporation
Object Type: Report
System: The UNT Digital Library
45-Day safety screening results for tank 241-U-102, push mode cores 143 and 144 (open access)

45-Day safety screening results for tank 241-U-102, push mode cores 143 and 144

This document is the 45-day report deliverable for tank 241-U-102 push mode core segments collected between April 16, 1996 and May 6, 1996 and received by the 222-S Laboratory between April 17, 1996 and May 8, 1996. The segments were subsampled and analyzed in accordance, with the Tank 241-U-102 Push Mode Core Sampling and analysis Plan (TSAP) (Hu, 1996) and the Safety Screening Data Quality Objective (DQO) (Dukelow, et al., 1995). The analytical results are included in Table 1. Attachment I is a cross reference to relate the tank farm identification numbers to the 222-S Laboratory LabCore sample numbers. The subsamples generated in the laboratory for analysis are identified in these diagrams with their sources shown. The diagram identifying the hydrostatic head fluid (HHF) blank is also included, Primary safety screening results and the raw data from Differential Scanning Calorimetry (DSC) and thermogravimetric analysis (TGA) analyses are included in this report. Two of the samples submitted for DSC analysis exceeded notification limits as stated in the Safety Screening DQO (Dukelow, et al., 1995). Cyanide analysis was requested on these samples and a Reactive System Screening Tool analysis was requested for the sample exhibiting the highest exothenn in accordance with the …
Date: June 28, 1996
Creator: Steen, F. H.
Object Type: Report
System: The UNT Digital Library
100-DR-1 radiological surveys (open access)

100-DR-1 radiological surveys

This report summarizes and documents the results of the radiological surveys conducted over the surface of the 100-DR-1 Operable Unit, Hanford Site, Richland, Washington. In addition, this report explains the survey methodology using the Ultrasonic Ranging and Data System (USRADS). The 100-DR-1 radiological survey field task consisted of two activities: characterization of the operable unit-specific background conditions and the radiological survey of the operable unit surface area. The survey methodology was based on utilization of USRADS for automated recording of the gross gamma radiation levels at or near 6 in. and at 3 ft from the surface soil. The purpose of the survey is to identify the location of unidentified subsurface radioactive material areas and any surface contamination associated with these areas. The radiological surveys were conducted using both a digital count rate meter with a NaI detector reporting in counts per minute (CPM) and a dose rate meter reporting micro-Roentgen per hour (uR) connected to a CHEMRAD Tennessee Corp. Series 2000 USRADS. The count rate meter was set for gross counting, i.e., Window ``out``. The window setting allows detection of low, intermediate, and high energy photons. The USRADS equipment is used to record the detector readings verses the location …
Date: January 28, 1994
Creator: Naiknimbalkar, N. M.
Object Type: Report
System: The UNT Digital Library
221-U Facility concrete and reinforcing steel evaluations specification for the canyon disposition initiative (CDI) (open access)

221-U Facility concrete and reinforcing steel evaluations specification for the canyon disposition initiative (CDI)

This describes a test program to establish the in-situ material properties of the reinforced concrete in Building 221-U for comparison to the original design specifications. Field sampling and laboratory testing of concrete and reinforcing steel structural materials in Building 221-U for design verification will be undertaken. Forty seven samples are to be taken from radiologically clean exterior walls of the canyon. Laboratory testing program includes unconfined compressive strength of concrete cores, tensile strength of reinforcing steel, and petrographic examinations of concrete cores taken from walls below existing grade.
Date: May 28, 1998
Creator: Baxter, J. T.
Object Type: Report
System: The UNT Digital Library
241-SY-101 DACS instrument problem screen (SCR 448) acceptance test procedure (open access)

241-SY-101 DACS instrument problem screen (SCR 448) acceptance test procedure

The operability of the 241-SY-101 Data Acquisition and Control System (DACS) to provide proper control and monitoring of the mitigation mixer pump and instrumentation installed in the 241-SY-101 underground storage tank utilizing the [INSTPROB] screen will be systematically evaluated by the performance of this procedure.
Date: June 28, 1999
Creator: Ermi, A. M.
Object Type: Report
System: The UNT Digital Library
242-A evaporator vacuum condenser system (open access)

242-A evaporator vacuum condenser system

This document is written for the 242-A evaporator vacuum condenser system (VCS), describing its purpose and operation within the evaporator. The document establishes the operating parameters specifying pressure, temperature, flow rates, interlock safety features and interfacing sub-systems to support its operation.
Date: September 28, 1994
Creator: Smith, V. A.
Object Type: Report
System: The UNT Digital Library
300 Area Treated Effluent Disposal Facility computer software release cover sheet and revision record (open access)

300 Area Treated Effluent Disposal Facility computer software release cover sheet and revision record

This supporting document contains the computer software release cover sheet and revision records for the 300 Area Treated Effluent Disposal Facility (TEDF). The previous revision was controlled by CH2M Hill which developed the software. A 7-page listing of the contents of directory C:{backslash}TEDF is contained in this report.
Date: November 28, 1994
Creator: McCarthy, R. J.
Object Type: Report
System: The UNT Digital Library
327 Building liquid waste handling options modification project plan (open access)

327 Building liquid waste handling options modification project plan

This report evaluates the modification options for handling radiological liquid waste (RLW) generated during decontamination and cleanout of the 327 Building. The overall objective of the 327 Facility Stabilization Project is to establish a passively safe and environmentally secure configuration of the 327 Facility. The issue of handling of RLW from the 327 Facility (assuming the 34O Facility is not available to accept the RLW) has been conceptually examined in at least two earlier engineering studies (Parsons 1997a and Hobart l997). Each study identified a similar preferred alternative that included modifying the 327 Facility RLWS handling systems to provide a truck load-out station, either within the confines of the facility or exterior to the facility. The alternatives also maximized the use of existing piping, tanks, instrumentation, controls and other features to minimize costs and physical changes. An issue discussed in each study involved the anticipated volume of the RLW stream. Estimates ranged between 113,550 and 387,500 liters in the earlier studies. During the development of the 324/327 Building Stabilization/Deactivation Project Management Plan, the lower estimate of approximately 113,550 liters was confirmed and has been adopted as the baseline for the 327 Facility RLW stream. The goal of this engineering study …
Date: March 28, 1998
Creator: Ham, J.E.
Object Type: Report
System: The UNT Digital Library
1998 federal energy and water management award winners (open access)

1998 federal energy and water management award winners

Energy is a luxury that no one can afford to waste, and many Federal Government agencies are becoming increasingly aware of the importance of using energy wisely. Thoughtful use of energy resources is important, not only to meet agency goals, but because energy efficiency helps improve air quality. Sound facility management offers huge savings that affect the agency`s bottom line, the environment, and workplace quality. In these fiscally-modest times, pursuing sound energy management programs can present additional challenges for energy and facility managers. The correct path to take is not always the easiest. Hard work, innovation, and vision are characteristic of those who pursue energy efficiency. That is why the Department of energy, Federal Energy Management Program (FEMP) is proud to salute the winners of the 1998 Federal Energy and Water Management Award. The 1998 winners represent the kind of 21st century thinking that will help achieve widespread Federal energy efficiency. In one year, the winners, through a combination of public and private partnerships, saved more than $222 million and 10.5 trillion Btu by actively identifying and implementing energy efficiency, water conservation, and renewable energy projects. Through their dedication, hard work, ingenuity, and success, the award winners have also inspired …
Date: October 28, 1998
Creator: unknown
Object Type: Report
System: The UNT Digital Library
2F and 2H evaporator loop evaluation closure report (open access)

2F and 2H evaporator loop evaluation closure report

As a result of the Concentrate Transfer System (CTS) tank ventilation system contamination event, a task team was formed to evaluate instrument loops associated with waste reduction equipment. During the event a conductivity probe designed to provide an alarm and initiate an interlock failed to respond to the presence of liquid. An investigation revealed that the probe had become disconnected from the loop. The daily functional check of the conductivity probe circuit only tested the circuit continuity from the ventilation unit to the control room and did not actually test the probe. To test the continuity, a test switch was used to simulate the conducting probe. Because the functional check did not test each part of the loop, the test could be satisfactorily completed even though the probe itself was inoperable. The function of the task team was to develop a list of loops and interlocks prioritized by importance and likelihood of similar failure. The team evaluated the associated loop calibration and functional test procedures to verify that they are adequate to ensure loop performance on a periodic frequency. This report documents the evaluation findings and associated actions required prior to startup of the 2F and 2H evaporators.
Date: January 28, 1994
Creator: Bates, W. F.
Object Type: Report
System: The UNT Digital Library
2F Evaporator CP class instrumentation uncertainties evaluations (open access)

2F Evaporator CP class instrumentation uncertainties evaluations

There are two instrumentation systems in the 2F Evaporator facilities (bldg. 242-16F) that are classified as the Critical Protection (CP). They are the Evaporator Pot Temperature instrumentations and Steam Condensate Gamma Monitor. The pot instrumentation consists of two interrelated circuits sharing the same temperature sensor and transducer. They are the high alarm and interlock circuit and the recorder circuit. The gamma monitor instrumentation consists of four interrelated circuits sharing the same scintillation detector. They are the gamma alarm and interlock circuit, failure alarm and interlock circuit, condensate cesium activity recorder circuit, and condensate americium activity recorder circuit. The resulting uncertainties for the instrument circuits are tabulated. (GHH)
Date: January 28, 1994
Creator: Hwang, Edward
Object Type: Report
System: The UNT Digital Library
2nd Workshop on Satellites for Solar Energy Assessments (open access)

2nd Workshop on Satellites for Solar Energy Assessments

A Collection of Presentations on new techniques for developing climatological estimates of the solar resource at all locations on earth at a resolution of 100km, and of developing estimates at half-hour intervals at resolutions of 10 km or less in specific locations.
Date: June 28, 1999
Creator: Renne, D.
Object Type: Article
System: The UNT Digital Library
3D finite-difference frequency-domain code for electromagnetic induction tomography (open access)

3D finite-difference frequency-domain code for electromagnetic induction tomography

The effect of shrapnel on target chamber components and experiments at large lasers such as the National Ignition Facility at LLNL and the Megajoule Laser at CESTA in France is an important issue in fielding targets and exposure samples. Modeling calculations are likely to be an important component of this effort. Some work in this area has been performed by French workers, who are collaborating with the LLNL on many issues relating to target chamber, experiment-component, and diagnostics survival. Experiments have been performed at the PhCbus laser in France to measure shrapnel produced by laser-driven targets; among these shots were experiments that accelerated spheres of a size characteristic of some of the more damaging shrapnel. These spheres were stopped in polyethylene witness plates. The penetration depth is characteristic of the velocity of the shrapnel. Experimental calibration of steel sphere penetration into polyethylene was performed at the CESTA facility. The penetration depth has been reported (ref. 1) and comparisons with modeling calculations have been made (ref. 2). There was interest in a comparison study of the modeling of these experiments to provide independent checks of the calculations. This work has been approved both by DOE headquarters and by the French Atomic …
Date: July 28, 1999
Creator: Berryman, J. G.; Champagne, N. J., II & Buettner, H. M.
Object Type: Article
System: The UNT Digital Library
Accelerating Thick Aluminum Liners Using Pulsed Power (open access)

Accelerating Thick Aluminum Liners Using Pulsed Power

The authors have investigated the acceleration of very thick cylindrical aluminum liners using the Pegasus II capacitory bank. These accelerated solid liners will be used to impact other objects at velocities below 1.5 km/sec, allowing one to generate and sustain shocks of a few 100 kilobar for a few microseconds. A cylindrical shell of 1100 series aluminum with an initial inner radius of 23.61 mm, an initial thickness of 3.0 mm, and a height of 20 mm, was accelerated using a current pulse of 7.15 MA peak current and a 7.4 microsecond quarter cycle time. The aluminum shell was imploded within confining copper glide planes with decreasing separation with an inward slope of 8 degrees. At impact with a cylindrical target of diameter 3-cm, the liner was moving at 1.4 km/sec and its thickness increased to 4.5 mm. Radial X-ray radiograms of the liner showed both the liner and the glide plane interface. The curvature of the inner surface of the liner was measured before impact with the 15-mm radius target. The radiograms also showed that the copper glide planes distorted as the liner radius decreased and that some axial stress is induced in the liner. The axial stresses did …
Date: June 28, 1999
Creator: Kyrala, George A.; Hammerburg, James E.; Bowers, David; Stokes, John; Morgan, Dane V.; Anderson, Wally E. et al.
Object Type: Article
System: The UNT Digital Library
Acceptance Test Procedure for Cathodic Protection, Rectifier 11 (open access)

Acceptance Test Procedure for Cathodic Protection, Rectifier 11

This Acceptance Test Procedure for Project W-030 Cathodic Protection Installation, 241-AY and 241-AZ Tank Farm Ventilation Upgrade, has been prepared to demonstrate that the cathodic protection system functions as required by project criteria.
Date: April 28, 1995
Creator: Clifton, F.T.
Object Type: Report
System: The UNT Digital Library
Acceptance test procedure for the MO-293 (1722) 10-wide mobile office (open access)

Acceptance test procedure for the MO-293 (1722) 10-wide mobile office

This Acceptance Test Procedure has been prepared to demonstrate that the Fire Protection System functions as required by project criteria. The test results will be issued as an acceptance test report after all the testing is complete. This facility is part of the Spent Nuclear Fuel Project. An appendix is provided as a checklist of activities to be performed by the fire alarm system installer to ensure proper installation and operation.
Date: December 28, 1994
Creator: Wallace, S. C.
Object Type: Report
System: The UNT Digital Library
Accuracy of Reservoir Predictions for the Nesjavellir Geothermal Field, Iceland (open access)

Accuracy of Reservoir Predictions for the Nesjavellir Geothermal Field, Iceland

The performance of the 1986 three-dimensional numerical model of the Nesjavellir geothermal field for predicting the deliverabilities and pressure decline of the wells during the period 1987 through 1991 is investigated. The model predicted adequately the flow rate and enthalpy transients of most wells, but overpredicted the pressure decline by 3 to 4 bars.
Date: January 28, 1993
Creator: Bodvarsson, G. S.; Gislason, G.; Gunnlaugsson, E.; Sigurdsson, O.; Stefansson, V. & Steingrimsson,B.
Object Type: Article
System: The UNT Digital Library
Achieving and maintaining cleanliness in NIF amplifiers (open access)

Achieving and maintaining cleanliness in NIF amplifiers

Cleanliness measurements made on AMPLAB prototype National Ignition Facility (NIF) laser amplifiers during assembly, cassette transfer, and amplifier operation are summarized. These measurements include particle counts from surface cleanliness assessments using filter swipe techniques and from airborne particle monitoring. Results are compared with similar measurements made on the Beamlet and Nova lasers and in flashlamp test fixtures. Observations of Class 100,000 aerosols after flashlamp firings are discussed. Comparisons are made between typical damage densities on laser amplifier optics from Novette, NOVA, Beamlet, and AMPLAB.
Date: July 28, 1998
Creator: Burnham, A. K.; Horvath, J. A.; Letts, S. A.; Menapace, J. A. & Stowers, I. F.
Object Type: Article
System: The UNT Digital Library
Actinide Biocolloid Formation in Brine by Halophilic Bacteria (open access)

Actinide Biocolloid Formation in Brine by Halophilic Bacteria

We examined the ability of a halophilic bacterium (WFP 1A) isolated from the Waste Isolation Pilot Plant (WIPP) site to accumulate uranium in order to determine the potential for biocolloid facilitated actinide transport. The bacterial cell Surface functional groups involved in the complexation of the actinide were determined by titration. Uranium, added as uranyl nitrate, was removed from solution at pH 5 by cells but at pH 7 and 9 very little uranium was removed due to its limited volubility. Although present as soluble species, uranyl citrate at pH 5, 7, and 9, and uranyl carbonate at pH 9 were not removed by the bacterium because they were not bioavailable due to their neutral or negative charge. Addition of uranyl EDTA to brine at pH 5, 7, and 9 resulted in the immediate precipitation of U. Transmission electron microscopy (TEM) and energy dispersive X-ray spectroscopy (EDS) analysis revealed that uranium was not only associated with the cell surface but also accumulated intracellulary as uranium-enriched granules. Extended X-ray absorption fine structure (EXAFS) analysis, of the bacterial cells indicated the bulk sample contained more than one uranium phase. Nevertheless these results show the potential for the formation of actinide bearing bacterial biocolloids …
Date: July 28, 1999
Creator: Gillow, J. B.; Francis, A. J.; Dodge, C. J.; Harris, R.; Beveridge, T. J.; Brady, P. V. et al.
Object Type: Article
System: The UNT Digital Library
Active and passive computed tomography for nondestructive assay (open access)

Active and passive computed tomography for nondestructive assay

Traditional gamma-ray methods used to characterize nuclear waste introduce errors that are related to non-uniform measurement responses associated with unknown radioactive source and matrix material distributions. These errors can be reduced by applying an active and passive tomographic technique (A&PCT) developed at the Lawrence Livermore National Laboratory (LLNL). The technique uses an external radioactive source and active tomography to map the attenuation within a waste barrel as a function of mono-energetic gamma-ray energy. Passive tomography is used to localize and identify specific radioactive waste within the same container. Reconstruction of the passive data using the attenuation maps at specific energies allows internal waste radioactivity to be corrected for any overlying heterogeneous materials, thus yielding an absolute assay of the waste activity. LLNL and Bio-Imaging Research, Inc. have collaborated in a technology transfer effort to integrate an A&PCT assay system into a mobile waste characterization trailer. This mobile system has participated in and passed several formal DOE-sponsored performance demonstrations, tests and evaluations. The system is currently being upgraded with multiple detectors to improve throughput, automated gamma-ray analysis code to simplify the assay, and a new emission reconstruction code to improve accuracy
Date: October 28, 1998
Creator: Bernardi, R. T.; Camp, D. E.; Clard, D.; Jackson, J. A.; Martz, H. E.; Decman, D. J. et al.
Object Type: Article
System: The UNT Digital Library
Activity plan for activity E-20-81: development and experimental validation of crevice corrosion models (open access)

Activity plan for activity E-20-81: development and experimental validation of crevice corrosion models

Alloy 22 [UNS N06022] is now being considered for construction of high level waste containers to be emplaced at the potential repository at Yucca Mountain or elsewhere. In essence, this alloy is 21% Cr, 13% Mo, 4% Fe, 3% W, 2% Co, with the balance being Ni. Variants without tungsten are also being considered. Detailed mechanistic models are being developed to account for the corrosion of Alloy 22 surfaces in crevices that will inevitably form. Such occluded areas experience substantial decreases in pH, with corresponding elevations in chloride concentration. Other relevant materials will also be investigated: nickel-based alloys such as Alloys 825, 625, C-4, C-276 and 59; titanium-based alloys such as Grades 12, 7 and 16, carbon steels such as A516 Grade 55; stainless steels such as 304, 304L, 316, 316L and 316NG; various copper-based alloys; and any materials that would serve as crevice formers (rock, thermally-sprayed ceramics, etc.). Experimental work has been undertaken to validate the crevice corrosion model, including parallel studies with 304 stainless steel. The crevice corrosion model is described in detail in scientific notebooks of the Principal Investigator, as well as other publications. Codes will be prepared in accordance with the YMP QP entitled ''Software Quality …
Date: December 28, 1999
Creator: Farmer, J C
Object Type: Report
System: The UNT Digital Library
Additional Development of a Dedicated Liquefied Petroleum Gas (LPG) Ultra Low Emissions Vehicle (ULEV) (open access)

Additional Development of a Dedicated Liquefied Petroleum Gas (LPG) Ultra Low Emissions Vehicle (ULEV)

This report describes the last in a series of three projects designed to develop a commercially competitive LPG light-duty passenger car that meets California ULEV standards and corporate average fuel economy (CAFE) energy efficiency guidelines for such a vehicle. In this project, IMPCO upgraded the vehicle's LPG vapor fuel injection system and performed emissions testing. The vehicle met the 1998 ULEV standards successfully, demonstrating the feasibility of meeting ULEV standards with a dedicated LPG vehicle.
Date: October 28, 1998
Creator: Technologies, IMPCO
Object Type: Report
System: The UNT Digital Library
Additional development of remote sensing techniques for observing morphology, microphysics, and radiative properties of clouds and tests using a new, robust CO{sub 2} lidar. Final report (open access)

Additional development of remote sensing techniques for observing morphology, microphysics, and radiative properties of clouds and tests using a new, robust CO{sub 2} lidar. Final report

A three-year project with a goal of advancing CO{sub 2} lidar technology and measurement techniques for cloud studies was successfully completed. An eyesafe, infrared lidar with good sensitivity and improved Doppler accuracy was designed, constructed, and demonstrated. Dual-wavelength operation was achieved. A major leap forward in robustness was demonstrated. CO{sub 2} lidars were operated as part of two Intensive Operations Periods at the Southern Great Plains CART site. The first used an older lidar and was intended primarily for measurement technique development. The second used the new lidar and was primarily a demonstration and evaluation of its performance. Progress was demonstrated in the development, evaluation, and application of measurement techniques using CO{sub 2} lidar.
Date: September 28, 1998
Creator: Eberhard, W.L.; Brewer, W.A. & Intrieri, J.M.
Object Type: Report
System: The UNT Digital Library
Advanced combustor design concepts to control NO{sub x} and air toxics. Quarterly report (open access)

Advanced combustor design concepts to control NO{sub x} and air toxics. Quarterly report

The University of Utah, Massachusetts Institute of Technology (MIT), Reaction Engineering International (REI) and ABB/Combustion Engineering have joined together in this research proposal to develop fundamental understanding regarding the impact of fuel and combustion changes on ignition stability and flame characteristics because these critically affect: NO{sub x} emissions, carbon burnout, and emissions of air toxics; existing laboratory and bench scale facilities are being used to generate critical missing data which will be used to improve the NO{sub x} and carbon burnout submodels in comprehensive combustion simulation tools currently being used by industrial boiler manufacturers. To ensure effective and timely transfer of This technology, a major manufacturer (ABB) and a combustion model supplier (REI) have been included as part of the team from the early conception of the proposal. ABB/Combustion Engineering is providing needed fundamental data on the extent of volatile evolution from commercial coals as well as background information on current design needs in industrial practice. MIT is responsible for the development of an improved char nitrogen oxidation model which will ultimately be incorporated into an enhanced NO{sup x} submodel. Reaction Engineering International is providing the lead engineering staff for the experimental studies and an overall industrial focus for the …
Date: April 28, 1995
Creator: Pershing, D.W.; Lighty, J.; Veranth, J.; Sarofim, A. & Goel, S.
Object Type: Report
System: The UNT Digital Library