Resource Type

82 Matching Results

Results open in a new window/tab.

Comparing the Floating Point Systems, Inc. AP-190L to representative scientific computers: some benchmark results (open access)

Comparing the Floating Point Systems, Inc. AP-190L to representative scientific computers: some benchmark results

Results are presented of comparative timing tests made by running a typical FORTRAN physics simulation code on the following machines: DEC PDP-10 with KI processor; DEC PDP-10, KI processor, and FPS AP-190L; CDC 7600; and CRAY-1. Factors such as DMA overhead, code size for the AP-190L, and the relative utilization of floating point functional units for the different machines are discussed. 1 table.
Date: March 27, 1980
Creator: Brengle, T.A. & Maron, N.
System: The UNT Digital Library
Dynamic Conductance of Carbon Nanotubes (open access)

Dynamic Conductance of Carbon Nanotubes

Article on dynamic conductance of carbon nanotubes.
Date: March 27, 2000
Creator: Roland, Christopher; Buongiorno Nardelli, Marco; Wang, Jian & Guo, Hong
System: The UNT Digital Library
Ultimate strength of carbon nanotubes: A theoretical study (open access)

Ultimate strength of carbon nanotubes: A theoretical study

Article on a theoretical study of the ultimate strength of carbon nanotubes.
Date: March 27, 2002
Creator: Zhao, Qingzhong; Buongiorno Nardelli, Marco & Bernholc, Jerry
System: The UNT Digital Library
Separation of Yeast Cells from MS2 Viruses Using Acoustic Radiation Force (open access)

Separation of Yeast Cells from MS2 Viruses Using Acoustic Radiation Force

We report a rapid and robust separation of Saccharomyces cerevisiae and MS2 bacteriophage using acoustic focusing in a microfluidic device. A piezoelectric transducer (PZT) generates acoustic standing waves in the microchannel. These standing waves induce acoustic radiation force fields that direct microparticles towards the nodes (i.e., pressure minima) or the anti-nodes (i.e., pressure maxima) of the standing waves depending on the relative compressidensity between the particle and the suspending liquid.[1] For particles larger than 2 {micro}m, the transverse velocities generated by these force fields enable continuous, high throughput separation. Extensive work in the last decade [2-4] has demonstrated acoustic focusing for manipulating microparticles or biological samples in microfluidic devices. This prior work has primarily focused on experimental realization of acoustic focusing without modeling or with limited one-dimensional modeling estimates. We recently developed a finite element modeling tool to predict the two-dimensional acoustic radiation force field perpendicular to the flow direction in microfluidic devices.[1] Here we compare results from this model with experimental parametric studies including variations of the PZT driving frequencies and voltages as well as various particle sizes and compressidensities. These experimental parametric studies also provide insight into the development of an adjustable 'virtual' pore-size filter as well as …
Date: March 27, 2008
Creator: Jung, B.; Fisher, K.; Ness, K.; Rose, K. A. & Mariella, R. P., Jr.
System: The UNT Digital Library
Coupled Reservoir-Geomechanical Analysis of the Potential for Tensile and Shear Failure Associated With CO2 Injection in Multilayered Reservoir-Caprock Systems (open access)

Coupled Reservoir-Geomechanical Analysis of the Potential for Tensile and Shear Failure Associated With CO2 Injection in Multilayered Reservoir-Caprock Systems

Coupled reservoir-geomechanical simulations were conductedto study the potential for tensile and shear failure e.g., tensilefracturing and shear slip along pre-existing fractures associated withunderground CO2 injection in a multilayered geological system. Thisfailure analysis aimed to study factors affecting the potential forbreaching a geological CO2 storage system and to study methods forestimating the maximum CO2 injection pressure that could be sustainedwithout causing such a breach. We pay special attention to geomechanicalstress changes resulting from upward migration of the CO2 and how theinitial stress regime affects the potential for inducing failure. Weconclude that it is essential to have an accurate estimate of thethree-dimensional in situ stress field to support the design andperformance assessment of a geological CO2 injection operation. Moreover,we also conclude that it is important to consider mechanical stresschanges that might occur outside the region of increased reservoir fluidpressure (e.g., in the overburden rock) between the CO2-injectionreservoir and the ground surface.
Date: March 27, 2007
Creator: Rutqvist, J.; Birkholzer, J. T. & Tsang, C.-F.
System: The UNT Digital Library
Least Squares Magnetic-Field Optimization for Portable Nuclear Magnetic Resonance Magnet Design (open access)

Least Squares Magnetic-Field Optimization for Portable Nuclear Magnetic Resonance Magnet Design

Single-sided and mobile nuclear magnetic resonance (NMR) sensors have the advantages of portability, low cost, and low power consumption compared to conventional high-field NMR and magnetic resonance imaging (MRI) systems. We present fast, flexible, and easy-to-implement target field algorithms for mobile NMR and MRI magnet design. The optimization finds a global optimum ina cost function that minimizes the error in the target magnetic field in the sense of least squares. When the technique is tested on a ring array of permanent-magnet elements, the solution matches the classical dipole Halbach solution. For a single-sided handheld NMR sensor, the algorithm yields a 640 G field homogeneous to 16 100 ppm across a 1.9 cc volume located 1.5 cm above the top of the magnets and homogeneous to 32 200 ppm over a 7.6 cc volume. This regime is adequate for MRI applications. We demonstrate that the homogeneous region can be continuously moved away from the sensor by rotating magnet rod elements, opening the way for NMR sensors with adjustable"sensitive volumes."
Date: March 27, 2008
Creator: Paulsen, Jeffrey L; Franck, John; Demas, Vasiliki & Bouchard, Louis-S.
System: The UNT Digital Library
SHIELDING ANALYSIS FOR X-RAY SOURCES GENERATED IN TARGET CHAMBER OF THE NATIONAL IGNITION FACILITY (open access)

SHIELDING ANALYSIS FOR X-RAY SOURCES GENERATED IN TARGET CHAMBER OF THE NATIONAL IGNITION FACILITY

Prompt doses from x-rays generated as result of laser beam interaction with target material are calculated at different locations inside the National Ignition Facility (NIF). The maximum dose outside a Target Chamber diagnostic port is {approx} 1 rem for a shot utilizing the 192 laser beams and 1.8 MJ of laser energy. The dose during a single bundle shot (8 laser beams) drops to {approx} 40 mrem. Doses calculated outside the Target Bay doors and inside the Switchyards (except for the 17 ft.-6 in. level) range from a fraction of mrem to about 11 mrem for 192 beams, and scales down proportionally with smaller number of beams. At the 17ft.-6 in. level, two diagnostic ports are directly facing two of the Target Bay doors and the maximum doses outside the doors are 51 and 15.5 mrem, respectively. Shielding each of the two Target Bay doors with 1/4 in. Pb reduces the dose by factor of fifty. One or two bundle shots (8 to 16 laser beams) present a small hazard to personnel in the Switchyards.
Date: March 27, 2008
Creator: Khater, H Y; Brereton, S J & Singh, M S
System: The UNT Digital Library
Relativistic Many-body Moller-Plesset Perturbation Theory Calculations of the Energy Levels and Transition Probabilities in Na- to P-like Xe Ions (open access)

Relativistic Many-body Moller-Plesset Perturbation Theory Calculations of the Energy Levels and Transition Probabilities in Na- to P-like Xe Ions

Relativistic multireference many-body perturbation theory calculations have been performed on Xe{sup 43+}-Xe{sup 39+} ions, resulting in energy levels, electric dipole transition probabilities, and level lifetimes. The second-order many-body perturbation theory calculation of energy levels included mass shifts, frequency-dependent Breit correction and Lamb shifts. The calculated transition energies and E1 transition rates are used to present synthetic spectra in the extreme ultraviolet range for some of the Xe ions.
Date: March 27, 2007
Creator: Vilkas, M J; Ishikawa, Y & Trabert, E
System: The UNT Digital Library
HYDROGEN EFFECTS ON THE BURST PROPERTIES OF TYPE 304L STAINLESS STEEL FLAWED VESSELS (open access)

HYDROGEN EFFECTS ON THE BURST PROPERTIES OF TYPE 304L STAINLESS STEEL FLAWED VESSELS

The effect of hydrogen on the burst properties Type 304L stainless steel vessels was investigated. The purpose of the study was to compare the burst properties of hydrogen-exposed stainless steel vessels burst with different media: water, helium gas, or deuterium gas. A second purpose of the tests was to provide data for the development of a predictive finite-element model. The burst tests were conducted on hydrogen-exposed and unexposed axially-flawed cylindrical vessels. The results indicate that samples burst pneumatically had lower volume ductility than those tested hydraulically. Deuterium gas tests had slightly lower ductility than helium gas tests. Burst pressures were not affected by burst media. Hydrogen-charged samples had lower volume ductility and slightly higher burst pressures than uncharged samples. Samples burst with deuterium gas fractured by quasi-cleavage near the inside wall. The results of the tests were used to improve a previously developed predictive finite-element model. The results show that predicting burst behavior requires as a material input the effect of hydrogen on the plastic strain to fracture from tensile tests. The burst test model shows that a reduction in the plastic strain to fracture of the material will result in lower volume ductility without a reduction in burst pressure …
Date: March 27, 2008
Creator: Morgan, M; Monica Hall, M; Ps Lam, P & Dean Thompson, D
System: The UNT Digital Library
Improved Bacterial and Viral Recoveries from 'Complex' Samples using Electrophoretically Assisted Acoustic Focusing (open access)

Improved Bacterial and Viral Recoveries from 'Complex' Samples using Electrophoretically Assisted Acoustic Focusing

Automated front-end sample preparation technologies can significantly enhance the sensitivity and reliability of biodetection assays [1]. We are developing advanced sample preparation technologies for biowarfare detection and medical point-of-care diagnostics using microfluidic systems with continuous sample processing capabilities. Here we report an electrophoretically assisted acoustic focusing technique to rapidly extract and enrich viral and bacterial loads from 'complex samples', applied in this case to human nasopharyngeal samples as well as simplified surrogates. The acoustic forces capture and remove large particles (> 2 {micro}m) such as host cells, debris, dust, and pollen from the sample. We simultaneously apply an electric field transverse to the flow direction to transport small ({le} 2 {micro}m), negatively-charged analytes into a separate purified recovery fluid using a modified H-filter configuration [Micronics US Patent 5,716,852]. Hunter and O'Brien combined transverse electrophoresis and acoustic focusing to measure the surface charge on large particles, [2] but to our knowledge, our work is the first demonstration combining these two techniques in a continuous flow device. Marina et al. demonstrated superimposed dielectrophoresis (DEP) and acoustic focusing for enhanced separations [3], but these devices have limited throughput due to the rapid decay of DEP forces. Both acoustic standing waves and electric fields …
Date: March 27, 2008
Creator: Ness, K.; Rose, K.; Jung, B.; Fisher, K. & Mariella, R. P., Jr.
System: The UNT Digital Library
L-Shell Spectroscopy of Au as a Temperature Diagnostic Tool (open access)

L-Shell Spectroscopy of Au as a Temperature Diagnostic Tool

In order to develop plasma diagnostic for reduced-size hot hohlraums under laser irradiation, they have studied the L-shell emission from highly charged gold ions in the SuperEBIT electron beam ion trap. The resolving power necessary to identify emission features from individual charge states in a picket fence pattern has been estimated, and the observed radiation features have been compared with atomic structure calculations. They find that the strong 3d{sub 5/2} {yields} 2p{sub 3/2} emission features are particularly useful in determining the charge state distribution and average ion charge <Z>, which are strongly sensitive to the electron temperature.
Date: March 27, 2008
Creator: Trabert, E; Hansen, S B; Beiersdorfer, P; Brown, G V; Widmann, K & Chung, H K
System: The UNT Digital Library
Externally Dispersed Interferometry for Precision Radial Velocimetry (open access)

Externally Dispersed Interferometry for Precision Radial Velocimetry

Externally Dispersed Interferometry (EDI) is the series combination of a fixed-delay field-widened Michelson interferometer with a dispersive spectrograph. This combination boosts the spectrograph performance for both Doppler velocimetry and high resolution spectroscopy. The interferometer creates a periodic spectral comb that multiplies against the input spectrum to create moire fringes, which are recorded in combination with the regular spectrum. The moire pattern shifts in phase in response to a Doppler shift. Moire patterns are broader than the underlying spectral features and more easily survive spectrograph blurring and common distortions. Thus, the EDI technique allows lower resolution spectrographs having relaxed optical tolerances (and therefore higher throughput) to return high precision velocity measurements, which otherwise would be imprecise for the spectrograph alone.
Date: March 27, 2007
Creator: Erskine, D. J.; Muterspaugh, M. W.; Edelstein, J.; Lloyd, J.; Herter, T.; Feuerstein, W. M. et al.
System: The UNT Digital Library
Melting line and fluid structure factor of oxygen up to 24 GPa (open access)

Melting line and fluid structure factor of oxygen up to 24 GPa

None
Date: March 27, 2007
Creator: Weck, G.; Loubeyre, P.; Eggert, J.; Mezouar, M. & Hanfland, M.
System: The UNT Digital Library
Resonant Auger Effect at High X-Ray Intensity (open access)

Resonant Auger Effect at High X-Ray Intensity

The resonant Auger effect of atomic neon exposed to high-intensity x-ray radiation in resonance with the 1s {yields} 3p transition is discussed. High intensity here means that the x-ray peak intensity is sufficient ({approx} 10{sup 18} W/cm{sup 2}) to induce Rabi oscillations between the neon ground state and the 1s{sup -1}3p ({sup 1}P) state within the relaxation lifetime of the inner-shell vacancy. For the numerical analysis presented, an effective two-level model, including a description of the resonant Auger decay process, is employed. Both coherent and chaotic x-ray pulses are treated. The latter are used to simulate radiation from x-ray free-electron lasers based on the principle of self-amplified spontaneous emission. Observing x-ray-driven atomic population dynamics in the time domain is challenging for chaotic pulse ensembles. A more practical option for experiments using x-ray free-electron lasers is to measure the line profiles in the kinetic energy distribution of the resonant Auger electron. This provides information on both atomic population dynamics and x-ray pulse properties.
Date: March 27, 2008
Creator: Rohringer, N & Santra, R
System: The UNT Digital Library
Systematic effects in CALOR simulation code to model experimental configurations (open access)

Systematic effects in CALOR simulation code to model experimental configurations

CALOR89 code system is being used to simulate test beam results and the design parameters of several calorimeter configurations. It has been bench-marked against the ZEUS, D{theta} and HELIOS data. This study identifies the systematic effects in CALOR simulation to model the experimental configurations. Five major systematic effects are identified. These are the choice of high energy nuclear collision model, material composition, scintillator saturation, shower integration time, and the shower containment. Quantitative estimates of these systematic effects are presented. 23 refs., 6 figs., 7 tabs.
Date: March 27, 1991
Creator: Job, P.K.; Proudfoot, J. (Argonne National Lab., IL (USA)); Handler, T. (Tennessee Univ., Knoxville, TN (USA). Dept. of Physics and Astronomy) & Gabriel, T.A. (Oak Ridge National Lab., TN (USA))
System: The UNT Digital Library
Overview of coal conversion (open access)

Overview of coal conversion

The structure of coal and the processes of coal gasification and coal liquefaction are reviewed. While coal conversion technology is not likely to provide a significant amount of synthetic fuel within the next several years, there is a clear interest both in government and private sectors in the development of this technology to hedge against ever-diminishing petroleum supplies, especially from foreign sources. It is evident from this rather cursory survey that there is some old technology that is highly reliable; new technology is being developed but is not ready for commercialization at the present state of development. The area of coal conversion is ripe for exploration both on the applied and basic research levels. A great deal more must be understood about the reactions of coal, the reactions of coal products, and the physics and chemistry involved in the various stages of coal conversion processes in order to make this technology economically viable.
Date: March 27, 1981
Creator: Clark, B. R.
System: The UNT Digital Library
Molecular potentials and relaxation dynamics (open access)

Molecular potentials and relaxation dynamics

The use of empirical pseudopotentials, in evaluating interatomic potentials, provides an inexpensive and convenient method for obtaining highly accurate potential curves and permits the modeling of core-valence correlation, and the inclusion of relativistic effects when these are significant. As an example, recent calculations of the chi/sup 1/..sigma../sup +/ and a/sup 3/..sigma../sup +/ states of LiH, NaH, KH, RbH, and CsH and the chi/sup 2/..sigma../sup +/ states of their anions are discussed. Pseudopotentials, including core polarization terms, have been used to replace the core electrons, and this has been coupled with the development of compact, highly-optimized basis sets for the corresponding one- and two-electron atoms. Comparisons of the neutral potential curves with experiment and other ab initio calculations show good agreement (within 1000 cm/sup -1/ over most of the potential curves) with the difference curves being considerably more accurate.
Date: March 27, 1981
Creator: Karo, A.M.
System: The UNT Digital Library
Experimental test accelerator (ETA) (open access)

Experimental test accelerator (ETA)

The Lawrence Livermore Laboratory is constructing an induction linac with the following parameters 10kA, 50ns FWHM pulse width, 5MeV, and 5PPS. This paper describes the design features of the 2.5 MeV injector and it's associated pulsed power system.
Date: March 27, 1979
Creator: Hester, R. E.; Bubp, D. G.; Clark, J. C.; Chesterman, A. W.; Cook, E. G.; Dexter, W. L. et al.
System: The UNT Digital Library
ANALYSIS OF VENTING OF A RESIN SLURRY (open access)

ANALYSIS OF VENTING OF A RESIN SLURRY

A resin slurry venting analysis was conducted to address safety issues associated with overpressurization of ion exchange columns used in the Purex process at the Savannah River Site (SRS). If flow to these columns were inadvertently interrupted, an exothermic runaway reaction could occur between the ion exchange resin and the nitric acid used in the feed stream. The nitric acid-resin reaction generates significant quantities of noncondensable gases, which would pressurize the column. To prevent the column from rupturing during such events, rupture disks are installed on the column vent lines. The venting analysis models accelerating rate calorimeter (ARC) tests and data from tests that were performed in a vented test vessel with a rupture disk. The tests showed that the pressure inside the test vessel continued to increase after the rupture disk opened, though at a slower rate than prior to the rupture. Calculated maximum discharge rates for the resin venting tests exceeded the measured rates of gas generation, so the vent size was sufficient to relieve the pressure in the test vessel if the vent flow rate was constant. The increase in the vessel pressure is modeled as a transient phenomenon associated with expansion of the resin slurry/gas mixture …
Date: March 27, 2012
Creator: Laurinat, J. & Hensel, S.
System: The UNT Digital Library
Status Report of the DPHEP Study Group: Towards a Global Effort for Sustainable Data Preservation in High Energy Physics (open access)

Status Report of the DPHEP Study Group: Towards a Global Effort for Sustainable Data Preservation in High Energy Physics

None
Date: March 27, 2013
Creator: Akopov, Zaven; Amerio, Silvia; Asner, David; Avetisyan, Eduard; Barring, Olof; Beacham, James et al.
System: The UNT Digital Library
On Fayet-Iliopoulos Terms and de Sitter Vacua in Supergravity: Some Easy Pieces (open access)

On Fayet-Iliopoulos Terms and de Sitter Vacua in Supergravity: Some Easy Pieces

We clarify a number of issues on Fayet-Iliopoulos (FI) terms in supergravity, keeping the formalism at a minimum and making use of explicit examples. We explain why, if the U(1) vector is massive everywhere in field space, FI terms are not genuine and can always be redefined away or introduced when they are not present. We formulate a simple anomaly-free model with a genuine FI term, a classically stable de Sitter (dS) vacuum and no global symmetries. We explore the relation between N = 2 and N = 1 FI terms by discussing N = 1 truncations of N = 2 models with classically stable dS vacua.
Date: March 27, 2012
Creator: Catino, Francesca; Villadoro, Giovanni & Zwirner, Fabio
System: The UNT Digital Library
Extrinsic Sources of Scatter in the Richness-Mass Relation of Galaxy Clusters (open access)

Extrinsic Sources of Scatter in the Richness-Mass Relation of Galaxy Clusters

Maximizing the utility of upcoming photometric cluster surveys requires a thorough understanding of the richness-mass relation of galaxy clusters. We use Monte Carlo simulations to study the impact of various sources of observational scatter on this relation. Cluster ellipticity, photometric errors, photometric redshift errors, and cluster-to-cluster variations in the properties of red-sequence galaxies contribute negligible noise. Miscentering, however, can be important, and likely contributes to the scatter in the richness - mass relation of galaxy maxBCG clusters at the low mass end, where centering is more difficult. We also investigate the impact of projection effects under several empirically motivated assumptions about cluster environments. Using SDSS data and the maxBCG cluster catalog, we demonstrate that variations in cluster environments can rarely ({approx} 1%-5% of the time) result in significant richness boosts. Due to the steepness of the mass/richness function, the corresponding fraction of optically selected clusters that suffer from these projection effects is {approx} 5%-15%. We expect these numbers to be generic in magnitude, but a precise determination requires detailed, survey-specific modeling.
Date: March 27, 2012
Creator: Rozo, Eduardo; Koester, Benjamin; Nord, Brian; Wu, Hao-Yi; Evrard, August & Wechsler, Risa
System: The UNT Digital Library
PRESSURIZATION OF CONTAINMENT VESSELS FROM PLUTONIUM OXIDE CONTENTS (open access)

PRESSURIZATION OF CONTAINMENT VESSELS FROM PLUTONIUM OXIDE CONTENTS

Transportation and storage of plutonium oxide is typically done using a convenience container to hold the oxide powder which is then placed inside a containment vessel. Intermediate containers which act as uncredited confinement barriers may also be used. The containment vessel is subject to an internal pressure due to several sources including; (1) plutonium oxide provides a heat source which raises the temperature of the gas space, (2) helium generation due to alpha decay of the plutonium, (3) hydrogen generation due to radiolysis of the water which has been adsorbed onto the plutonium oxide, and (4) degradation of plastic bags which may be used to bag out the convenience can from a glove box. The contributions of these sources are evaluated in a reasonably conservative manner.
Date: March 27, 2012
Creator: Hensel, S.
System: The UNT Digital Library
Index Sets and Vectorization (open access)

Index Sets and Vectorization

Vectorization is data parallelism (SIMD, SIMT, etc.) - extension of ISA enabling the same instruction to be performed on multiple data items simultaeously. Many/most CPUs support vectorization in some form. Vectorization is difficult to enable, but can yield large efficiency gains. Extra programmer effort is required because: (1) not all algorithms can be vectorized (regular algorithm structure and fine-grain parallelism must be used); (2) most CPUs have data alignment restrictions for load/store operations (obey or risk incorrect code); (3) special directives are often needed to enable vectorization; and (4) vector instructions are architecture-specific. Vectorization is the best way to optimize for power and performance due to reduced clock cycles. When data is organized properly, a vector load instruction (i.e. movaps) can replace 'normal' load instructions (i.e. movsd). Vector operations can potentially have a smaller footprint in the instruction cache when fewer instructions need to be executed. Hybrid index sets insulate users from architecture specific details. We have applied hybrid index sets to achieve optimal vectorization. We can extend this concept to handle other programming models.
Date: March 27, 2012
Creator: Keasler, J A
System: The UNT Digital Library