The Design and Performance of Levitation Melting Coils (open access)

The Design and Performance of Levitation Melting Coils

The purpose of this study was to provide a means for evaluating the various parameters involved in the design and performance of levitation coils.
Date: April 26, 1963
Creator: Hulsey, William Jewell
System: The UNT Digital Library
The Inference of Adsorption from Differential Double Layer Capacitance Measurements (open access)

The Inference of Adsorption from Differential Double Layer Capacitance Measurements

From Abstract : "Dependence of boundary tension and capacitance at the mercury-aqueous 0.1 N HClO4 interface on polarization and organic solute concentration were determined for the colutes n-amyl alcohol and phenol. ... An earlier treatment proposed by this Laboratory based on a (non-thermodynamic) assumption of linear variation of surface charge density with coverage appears adequately justified for inference of fractional surface coverages near the electrocapillary maximum, but must be considered approximate for evaluation of molar area at full coverage in cases where linear variation of charge with coverage has not been demonstrated."
Date: April 26, 1963
Creator: Hansen, Robert S.; Kelsh, Dennis J. & Grantham, D. H.
System: The UNT Digital Library
Colloidal Radioalbumin Aggregates for Organ Scanning : presented at 10th Annual Meeting, Nuclear Medicine Society, Montreal, Canada, June 26-29, 1963 (open access)

Colloidal Radioalbumin Aggregates for Organ Scanning : presented at 10th Annual Meeting, Nuclear Medicine Society, Montreal, Canada, June 26-29, 1963

Abstract: The exhibit shows that colloidal aggregates (10 to 20 mu) of human serum albumin I131 may be used safely by intravenous injection to perform photoscans of the heart, liver, spleen, stomach, and salivary glands in man. Large particle size suspensions (10 to 50 mu) of the same material are being investigated experimentally in animals for scanning the lungs after intravenous injection and the brain following injection into an internal carotid artery. The advantages of this test material are the relatively low radiation exposure to the target organs and the number of organs that may be examined. Radiation exposure is low because of the rapid turnover in the target organs and removal from the body, mainly by urinary excretion, within 72 hours. The mechanism of liver-spleen localization with this organic colloid is the same as for inorganic colloidal radiogold198, namely, rapid removal from the blood by the phagocytic cells of the liver and spleen. However, in contrast to the inorganic colloid, which remains in the phagocytic cells permanently, albumin is digested by proteolytic enzymes and the I131 abel is set free to re-enter the general circulation. With the thyroid blocked, the I131 is excreted mainly in the urine as free …
Date: June 26, 1963
Creator: Taplin, George V.; Dore, Earl K.; Johnson, DeLores E. & Kaplan, Harriet.
System: The UNT Digital Library
High Power Density Development Project: Potter Meter Calibration and Instrumented Fuel Bundle Pressure Drop (open access)

High Power Density Development Project: Potter Meter Calibration and Instrumented Fuel Bundle Pressure Drop

Summary: Technical report describing the testing of eight Potter Meters, for metering inlet flow and measuring exit steam qualities in the Consumers Big Rock Point Instrumented Fuel Assemblies, were individually calibrated for flow and pressure drop up to 500 gpm in the low temperature (130 F) fluid flow facility. The flow calibration comparison made with an ASME orifice installation, agreed to within + - 1 percent among seven of the meters, and meter Serial No. 8 was 2.8 percent lower than the others. Pressure drop among the meters was within about 5 percent. Locked rotor pressure drop data was obtained on one meter. A fully instrumented fuel bundle was tested in the low temperature facility and pressure drop data obtained for the tieplates and meters, spacers, and channel rods. A mock-up of the exit end of the instrumented fuel bundles, composed of 1 foot of fuel rods, tieplate, and Potter Meter was tested in the High Pressure Heat Transfer Facility. Data was obtained for single- and two-phase calibration of total flow and exit steam quality in an instrumented bundle. Each meter was operated, for a minimum of 6-8 hours after bearing modifications necessitated by seizure of the rotors, in the …
Date: July 26, 1963
Creator: Polomik, E. E. & Swan, C. L.
System: The UNT Digital Library