Preliminary Investigation of a Variable-Area Auxiliary Air-Intake System at Mach Numbers From 0 to 1.3 (open access)

Preliminary Investigation of a Variable-Area Auxiliary Air-Intake System at Mach Numbers From 0 to 1.3

"A variable-area auxiliary air scoop in combination with a fixed-area nose intake was tested at Mach numbers from 0 to 1.3. The purpose of the investigation was to evaluate the effectiveness of such an auxiliary intake in improving the net thrust of an intake-engine combination over a range of speeds. The results indicated that the internal flow was always stable and that improvements in net thrust would be realized at Mach numbers up to about 1.1 for an intake design Mach number of 1.3" (p. 1).
Date: February 25, 1953
Creator: Scherrer, Richard; Stroud, John F. & Swift, John T.
System: The UNT Digital Library