Neutron Streaming in Steel: The Dependence of the Streaming on the Nickel Content of the Steel (open access)

Neutron Streaming in Steel: The Dependence of the Streaming on the Nickel Content of the Steel

The following report analyzes whether there is a difference between the neutron streaming in the "armor plate" and 347 stainless steel.
Date: May 25, 1953
Creator: Schamberger, Robert D. & Shore, Ferdinand J.
System: The UNT Digital Library
A Precise Potentiometric Titration Method for the Determination of Uranium (open access)

A Precise Potentiometric Titration Method for the Determination of Uranium

Abstract: "A precise potentiometric method for the determination of uranium in essentially pure uranium oxides is described. Ten gram samples of oxides are reduced in a Jones reductor and titrated potentiometrically to U+4, using platinum and tungsten electrodes. A weighed amount of solid Bureau of Standards potassium dichromate is then used to oxidize at least 99 percent of the uranous ion, and the oxidation is completed by titration with 0.01 N potassium dichromate using calomel and platinum electrodes. This method, which is based on a primary chemical standard, has a precision of +/- 0.015% on a single determination at the 95 percent confidence interval."
Date: August 25, 1953
Creator: Voss, F. S. & Greene, R. E.
System: The UNT Digital Library
Static Corrosion Tests of Fabrication Material for D-12 Waste Evaporator (open access)

Static Corrosion Tests of Fabrication Material for D-12 Waste Evaporator

Three types of stainless steel (309 SCB, Carpenter 20, 304-L) were exposed to both the liquid and vapor phase of each of three types of solutions. The time of exposure totaled ten days during which the specimens were cleaned and weighed periodically. The three synthetic D-12 waste solutions contained respectively chrome-high chloride, chrome-low chloride and high chloride sans chromium. The solutions were renewed at each weighing.
Date: June 25, 1953
Creator: Barnes, R. G.
System: The UNT Digital Library
The Spectrophotometric Determination of Boron in Plutonium Using an Oxalate Separation (open access)

The Spectrophotometric Determination of Boron in Plutonium Using an Oxalate Separation

An improved method for the determination of boron in plutonium is reported. Precipitation of plutonium (III) acid oxalate prior to color development with curcumin results in increased precision, greater speed, and lower costs. Results are presented of a statistical study involving all variables.
Date: June 25, 1953
Creator: Newell, Donald M.