Calorimetric Calibration of a Graphite Walled, Cavity-Type Ionization Chamber (open access)

Calorimetric Calibration of a Graphite Walled, Cavity-Type Ionization Chamber

Technical report outlining cavity-type ionization chambers with graphite walls that are used to measure heat dissipation in the graphite reflector of the MTR mock-up. Studies the relationship between the ionization occurring in the chamber and the heat generated in the surrounding graphite medium. [From Abstract]
Date: January 23, 1951
Creator: Jenks, G. H.; Breazeale, W. M. & Hairston, J. J.
System: The UNT Digital Library
Studies on the Removal of Radioisotopes From Liquid Wastes by Coagulation (open access)

Studies on the Removal of Radioisotopes From Liquid Wastes by Coagulation

Technical report covering work completed on the removal of radioisotopes from water using a calcium phosphate floc as a carrier. This research was performed as part of the Health Physics Waste Disposal Research Section work on the removal of small quantities of radioactivity from large volumes of water. [From Abstract]
Date: January 23, 1951
Creator: Lauderdale, Robert A., Jr.
System: The UNT Digital Library
A Manual of HRE Control and Instrumentation (open access)

A Manual of HRE Control and Instrumentation

Technical reports outlining the controls for the Homogeneous Reactor Experiment (HRE); controls are divided into three principal groups. 1. Reactor. 2. Process or auxiliary. 3. Power generation. These are the classifications designating the primary functions of the controls. [From Introduction]
Date: January 23, 1952
Creator: Quarles, L. R. & Walker, W. P.
System: The UNT Digital Library
Eddy-Current Measurement of Clad Thickness on Mark X MTR Fuel Plates (open access)

Eddy-Current Measurement of Clad Thickness on Mark X MTR Fuel Plates

At the request of the Alloy Preparation Group, the Nondestructive Test Development Group investigated the feasibility of determining the clad thickness on Mark X MTR Fuel Plates. As the use of induced eddy-currents was considered to be the most promising approach, a prototype instrument and probe coil utilizing this principle was developed to measure clad thickness. The results of the investigation conducted with this instrument indicate that the clad thickness of this type of fuel plats can be measured to withing +- 0.001 in.
Date: January 23, 1957
Creator: Oliver, R. B.; Allen, J. W. & Nance, Roy A.
System: The UNT Digital Library
Xenon and Samarium Poisoning (open access)

Xenon and Samarium Poisoning

The equilibrium and maximum override values for xenon and samarium poisoning have been computed using the recently issued effective cross sections of C. H. Westcott. Values are given as a function of specific power, neutron temperature, and epithermal flux content.
Date: January 23, 1961
Creator: Carlsmith, R. S.
System: The UNT Digital Library