Serial/Series Title

Month

3 Matching Results

Results open in a new window/tab.

New Description of Thorium Spectra (open access)

New Description of Thorium Spectra

Report discussing wavelengths and estimated intensities in electrodeless lamp and spark sources presented for 15121 lines of ThI, ThII, ThIII, and ThIV in the spectral range from 2000 to 11550 A. Also contains tables of previously published interferometric values.
Date: June 21, 1960
Creator: Zalubas, Romuald
System: The UNT Digital Library
Temperature-Induced Stresses in Solids of Elementary Shape (open access)

Temperature-Induced Stresses in Solids of Elementary Shape

Report discussing how solids subjected to non-uniform temperature change develop internal stresses determined by, (1) the temperature distribution within the solid, and (2) certain physical constants of the material. For two varieties of heating, the equations determining stress have been put in convenient form for practical use, and tables of certain temperature functions show how to determine stresses in a slab, in a cylinder, or in a sphere subjected to either of two modes of heating. The temperature-distribution tables independently provide a useful means for the ready estimation of temperature gradients.
Date: June 21, 1960
Creator: Adams, Leason H. & Waxler, Roy M.
System: The UNT Digital Library
Vibration-Rotation Structure in Absorption Bands for the Calibration of Spectrometers From 2 to 16 Microns (open access)

Vibration-Rotation Structure in Absorption Bands for the Calibration of Spectrometers From 2 to 16 Microns

Reports discussing bands of common gases that have been tabulated and remeasured wherever necessary from 2 to 16 microns to obtain an accuracy of about 0.03 cm-1 throughout the region and to provide good calibrating points at frequent intervals. Some 600 rotation-vibration lines are illustrated in 20 spectrograms and wavenumbers are listed in companion tables with considerable intercomparison with worthy data obtained in other laboratories. The absorption bands were remeasured or calibrated by using either a precisely graduated grating circle or standard atomic lines with the fringe system formed by a Fabry-Perot interferometer. Characteristic features of the individual bands are discussed briefly and references to other publications are given. The substances used for calibration include H2O, CO2, CO, HCl, HBr, NH3, C2H2, CH4, N2O, and polystyrene film.
Date: June 21, 1960
Creator: Plyler, Earle K.; Danti, Alfred; Blaine, L. R. & Tidwell, E. D.
System: The UNT Digital Library