Development of Pulsed Neutron Application to Power Reactor Start-Up Procedures. Sixth Quarterly Progress Report, July 1-September 30, 1963 (open access)

Development of Pulsed Neutron Application to Power Reactor Start-Up Procedures. Sixth Quarterly Progress Report, July 1-September 30, 1963

Activities in a program to develop techniques in the use of pulsed neutron sources to measure shutdown parameters related to large thermal power reactors are reported. The development of pulsed neutron source techniques for large power reactors has led to a new theoretical model recently developed by E. Garelis and J.L. Russell, Jr. The theory is presently based on a bare, one-group model with m-delayed precursors and takes all spatial modes into account. Results indicate, however, that the application of this model is much broader. Experiments were designed and carried out to both verify this new theory and to demonstrate the performance of the experimental hardware in a large power reactor.
Date: October 15, 1963
Creator: Garelis, Edward & Meyer, P.
System: The UNT Digital Library
Environmental Testing of a B4C-Ni Prototype Control Rod (open access)

Environmental Testing of a B4C-Ni Prototype Control Rod

Summary: A prototype control rod containing absorber plates made from an electro- deposited dispersion of boron carbide in nickel was tested in the VBWR. It was exposed to the reactor environment of 545 degree F boiling water and thermal neutron fluxes (perturbed) which ranged from 0.6 to 1.1 x 10/sup 13/ nv for 2236 hours over a period of six months. The maximum B/sup 10/ burnup achieved during the test period was 1.8 percent. After irradiation, the rod was examined. The results of the examination are summarized below: (1) The B/sub 4/C-- Ni plate assembly did not undergo significant dimensional changes during irradiation. (2) Numerous blisters developed on both the outer and inner surfaces of three of the four plates. Blistering was more severe on the outer surface than on the inner, and was most severe in a large region located in the lower half of plate 4. Metallographic examination revealed that the blisters were located only in the 2- mil protective nickel overlay covering the B/sub 4/C-- Ni dispersion. It was concluded that they formed from the buildup of gas pressure at the Ni: Ni-- B/sub 4/C interfaces, rather than from corrosion attack. Helium from the B/sup 10/(n alpha …
Date: October 15, 1963
Creator: Megerth, F. H. & Zimmerman, D. L.
System: The UNT Digital Library