Serial/Series Title

Corrosion Tests : SAE 1010 Mild Steel in Synthetic Neutralized Redox Waste Solution (open access)

Corrosion Tests : SAE 1010 Mild Steel in Synthetic Neutralized Redox Waste Solution

From introduction: "This report gives the results of a 1000-hour corrosion test of SAE 1010, low carbon steel, in synthetic Redox waste solutions...The present test was designed to obtain corrosion rates for waste solution temperatures of 180 F, 200 F, and 220 F in solutions neutralized to pH values of 11, 12, and 13.
Date: November 13, 1952
Creator: Endow, Noborn
System: The UNT Digital Library
Proposed Method for Treating Hydrogen Displacement Effects in Critical Mass Measurements (open access)

Proposed Method for Treating Hydrogen Displacement Effects in Critical Mass Measurements

This report discusses a proposed method for treating the effect of increasing critical mass of plutonium solutions, which occurs when hydrogen density is reduced by dilution with heavier nuclei.
Date: May 13, 1952
Creator: Gast, Paul F.
System: The UNT Digital Library
Corrosion Test of Type 502 Stainless Steel (open access)

Corrosion Test of Type 502 Stainless Steel

The following report provides complete data and test procedure from hot water corrosion tests of type 502 stainless steel.
Date: August 13, 1952
Creator: Zimmerman, D. L.
System: The UNT Digital Library
Investigation of Sulfamic Acid Tank Valve Failures (open access)

Investigation of Sulfamic Acid Tank Valve Failures

This report examines the failure of two 18-8 grade stainless steel gate valves used in sulfamic acid and determines the cause of the failures through a series of tests.
Date: November 13, 1952
Creator: Endow, N.
System: The UNT Digital Library