12 Matching Results

Results open in a new window/tab.

An Improved Nuclear Density Gauge : Covering the Interval of June 1 to July 1, 1959 (open access)

An Improved Nuclear Density Gauge : Covering the Interval of June 1 to July 1, 1959

The following document is a note describing the building process of an improved nuclear density gauge in comparison to previous gauges, within the interval of June 1 to July 1, 1959.
Date: June 8, 1959
Creator: Burgwald, G. M. & Stone, C. A.
System: The UNT Digital Library
An Improved Nuclear Density Gauge : Quarterly Report No. 1 Covering the Period from June 1 to September 1, 1959 (open access)

An Improved Nuclear Density Gauge : Quarterly Report No. 1 Covering the Period from June 1 to September 1, 1959

This report discusses the concept of an improved mass gauging technique with a scintillation counter as the radiation detector in order to meet industrial requirements.
Date: October 8, 1959
Creator: Burgwald, G. M. & Stone, C. A.
System: The UNT Digital Library
Summary of HRT Run 14 (open access)

Summary of HRT Run 14

This report presents a detailed study of HRT Run 14, which was abruptly terminated by the formation of a hole in the Zircaloy-2 core tank. In this run the reactor was operated at high temperature and pressure for ten days from March 25 to April 4, 1958. Nuclear power operation extended from March 29 until April 4, when fuel solution leaked into the heavy-water blanket. The maximum power level attained was 6.4 Mw.
Date: June 8, 1959
Creator: Engel, J. R.; Haubenreich, P. N.; Kolb, J. O. & Richardson, D. M.
System: The UNT Digital Library
The Rate of Uranium Sorption by a Strong-Base Anion-Exchange Resin (open access)

The Rate of Uranium Sorption by a Strong-Base Anion-Exchange Resin

The rate of uranium sorption by a strong-base anion-exchange resin (Dovex 21K) from a uranyl sulfate solution (U 0.005 M, H2SO4 0.02M, SO4 0.2 M) was studied using a stirred vessel technique and measuring the U235 gamma radiation on each bead. Resin initially in the chloride form and the sulfate for was studied.
Date: July 8, 1959
Creator: Bresee, J. C.
System: The UNT Digital Library
Calculations for Irradiation of Natural UO2-ThO2 (open access)

Calculations for Irradiation of Natural UO2-ThO2

Calculations are given for eighteen stainless steel clad helium bonded specimens of UO2-ThO2 containing normal U to be placed in 6 holes in a holder in a position of the ORR not to exceed a peak unperturbed flux of 4 x 10^14 n.cm^2/sec and irradiated to a peak nvt of 1.96 x 10^21 neutrons/cm^2
Date: June 8, 1959
Creator: Ullmann, J. W.
System: The UNT Digital Library
Physical Properties of Neutralized Zirflex Waste (open access)

Physical Properties of Neutralized Zirflex Waste

Zirflex cladding waste is to be neutralized to pH 10 before transfer to waste storage tanks. This treatment causes the precipitation of zirconium oxide or hydroxide, which may lead to flow difficulties during transfer. The purpose of this investigation was to determine the physical properties and flow characteristics of the neutralized slurry to assist in the selectin of satisfactory transfer equipment and storage conditions.
Date: June 8, 1959
Creator: Amos, L. C.
System: The UNT Digital Library
Critical Incident Alarm - Model I Instruction and Maintenance Manual (open access)

Critical Incident Alarm - Model I Instruction and Maintenance Manual

The HAPO Critical Incident Alarm, Model I, is an instrument designed to give an audible and visual alarm signal in the event of a critical incident to which it is exposed. There will be thirty-one (31) of these instruments installed and several spares located in the various manufacturing buildings in the Chemical Processing Department where there exists any possibility of a critical incident occurring. The instrument is intended as a post or after-the-fact warning device. It will offer no protection prior or leading up to, nor prevent, a critical incident. They are intended to be operated from the 115 V. A.C., 60 C.P.S. emergency line power. The instrument is self-contained, including the radiation detector, and will be calibrated to alarm at 500 mr/hour in a gamma field.
Date: May 8, 1959
Creator: Kelly, P. R.
System: The UNT Digital Library
Improvements in Water Treatment for Once-Through Reactor Cooling (open access)

Improvements in Water Treatment for Once-Through Reactor Cooling

Nearly all nuclear reactors being designed and built today- whether for research, power, or productions of fissionable materials- use recirculating fluids for cooling. However, a number of production reactors are still operating with single-pass cooling by treated natural water. The Hanford Atomic Products Operation of the General Electric Company presently operates production reactors for the AEC at Richland, Washington. The first reactors were built during World War II, and utilized a standard water treatment which was designed to provide large quantities of settled, filtered Columbia River water for once-through cooling.
Date: May 8, 1959
Creator: Richman, R. B.
System: The UNT Digital Library
Study of Factors Influencing Ductility of Iron-Aluminum Alloys. Monthly Letter Report No. 8, 15 March 1959 to 15 March 1960 (open access)

Study of Factors Influencing Ductility of Iron-Aluminum Alloys. Monthly Letter Report No. 8, 15 March 1959 to 15 March 1960

Studies are being made on the effects of variation of aluminum content, heat treatment, surface preparation, and other metallurgical factors on the room temperature ductility of Al-- Fe alloys. It is estimated that approximately 65 percent of the proposed research has been completed over the first eight and one-half months of the contract period.
Date: December 8, 1959
Creator: Perkins, Frank C. & Nachman, J. F. (Joseph F.)
System: The UNT Digital Library
Condensate System. Section II. Fifth Core I, Seed 1. Test Results DL-S-105 (open access)

Condensate System. Section II. Fifth Core I, Seed 1. Test Results DL-S-105

The purpose of the test was to fill the condensate storage tank and the Condensate System and obtain satisfactory preliminary operation. The components of the Condensate System performed adequately and satisfactorily with the exception of fill control valve (M9-VI). This valve (M9-VI) is not used in the current operation procedure.
Date: December 8, 1959
Creator: unknown
System: The UNT Digital Library
Chemical Development Section C Monthly Progress Report August 1959 (open access)

Chemical Development Section C Monthly Progress Report August 1959

Uranium extractions from carbonate solutions were effective and phase separation rates were rapid using a new commercial quaternary extractant, Alamine 336. Extraction coefficients were approximately proportional to the quaternary concentration. Addition of -0.5 mole tridecanol/mole quaternary to the solvent gave optimum extraction efficiency and phase separation rates.
Date: September 8, 1959
Creator: Brown, K. B.; Allen, K. A.; Coleman, C. F.; Crouse, D. J. & Ryon, A. D.
System: The UNT Digital Library
Nuclear Instrumentation Operation During Plant Operation. Section I. First Performance. Core I, Seed 1. Test Results DL-S-309, RNI-41 (open access)

Nuclear Instrumentation Operation During Plant Operation. Section I. First Performance. Core I, Seed 1. Test Results DL-S-309, RNI-41

The purpose of the test was to evaluate the operation of the Nuclear Instrumentation Power Range Amplifier during start up. While the station was operating at a gross load of 16.5 megawatts, a variation of 0, 8.5, 2.7 and 4.4 existed between the compensated ion chamber currents (CIC) and the test currents for channels A, B, C and D respectively. The off site modifications to channel C power range amplifier did not cause the ion chamber current and test current to be the same at 16.5 megawatts gross power. The modifications to channel C were made to correct for this deficiency.
Date: December 8, 1959
Creator: unknown
System: The UNT Digital Library