Serial/Series Title

Corrosion of Stellite in MJ-1 Streams (open access)

Corrosion of Stellite in MJ-1 Streams

The following report provides data from completed tests for corrosion testing of stellite-T347 stainless steel test cylinders.
Date: March 8, 1950
Creator: Koenig, W. W.
System: The UNT Digital Library
Infrared Absorption Measurements Indicating Intermolecular Association of Water and Hexone (open access)

Infrared Absorption Measurements Indicating Intermolecular Association of Water and Hexone

This report analyzes infrared absorption measurements that were made in the regions of carbonyl band and hydroxyl band absorptions on solutions of water in hexone and water in acetone, confirming intermolecular association of water and hexone.
Date: March 8, 1950
Creator: Moore, R. H.
System: The UNT Digital Library
Application and Operation of the 325 Building Well Counter (open access)

Application and Operation of the 325 Building Well Counter

Well-type scintillation counters have found use in many radiochemical laboratories. A gamma scintillation well counter has been used to measure the gamma activity of liquid samples in the 325 Building counting room for about a year. This well counter has been built and calibrated so that gamma activity measurements made with it can be easily compared with measurements made with the gamma scintillation counter (GSC). The well counter is electronically identical to the present GSC and differs only in the shape of the crystal used and the physical arrangement of the lead shield. The crystal contains a well which allows a tube containing the sample to be inserted in the crystal. The physical arrangement of the detector greatly simplifies the preparation of liquid samples for activity measurement. The 325 Building well counter and its application to chemical research and plant process analysis will be discussed in the following paragraphs. An operating procedure is also included.
Date: March 8, 1956
Creator: Brauer, F. P.
System: The UNT Digital Library
100-N Decontamination Facility Design Guide. (open access)

100-N Decontamination Facility Design Guide.

Space has been reserved near the southeast corner of the 100-N Area for the 122-N Decontamination Facility. Previous correspondence between Burns and Roe, Inc and General Electric bae discussed various facilities which might be needed in the building. The concepts of the decontamination processes are under active development by research groups at Hanford. At present, there are several workable processes known; each one has one or more fairly serious drawbacks.
Date: March 8, 1960
Creator: Bainard, W. D.
System: The UNT Digital Library
Critical Pressure Ratio for a Nozzle with Two-Phase Fog Flow (open access)

Critical Pressure Ratio for a Nozzle with Two-Phase Fog Flow

In many cases of analysis of two-phase flow in systems, considerable computation or program time could be saved if the critical pressures ratio were known. If a reservoir or plenum pressure is fixed, the usual computational procedure involves the assumption of several critical pressures and the generation of several momentum terms to find the applicable critical pressure ratio and thereby the critical flow. The formulation of an equation of state make it possible to compute critical pressure ratios directly.
Date: March 8, 1960
Creator: Love, W. J.
System: The UNT Digital Library
Glove Box Integrity Study (open access)

Glove Box Integrity Study

The amount of dry air or inert gas supplied to a "one pass" glove box ventilation system is proportional to the glove box inleakage. Most glove boxes in the 234r5 Building are equipped with sundry attachments, each contributing to the inleakage. No individual leak rate date is available for these auxiliary components in the "as installed" condition. Nor is the effect of time upon the leak rates known. Knowledge of these values, or at least an indication of the order of magnitude of the leakage attributable to each item, would provide a basis for analyzing glove box ventilation problems and for establishing criteria for new glove box designs.
Date: March 8, 1960
Creator: Ciccarelli, R. A.
System: The UNT Digital Library
Preliminary Evaluation of Chlorine for Use as a Gas Cooled Reactor Safeguard* (open access)

Preliminary Evaluation of Chlorine for Use as a Gas Cooled Reactor Safeguard*

A coolant line rupture during operation of a high temperature gas cooled graphite moderated reactor would present a serious hazard. The reactor would immediately depressurize and a great deal of air would be introduced into the coolant stream. As the air passed over the graphite moderator a runaway oxidation reaction would probably ensue unless an adequate safety system were available. This investigation was designed to evaluate chlorine as a reactor safeguard to be used to control a runaway reaction. Throughout this study, a small amount of chlorine in an air stream has demonstrated the ability to substantially reduce the oxidation rate of graphite. This has been the case even where the principal oxidizing agent was molecular oxygen or ozone.
Date: March 8, 1960
Creator: Dahl, R. E.
System: The UNT Digital Library