Stress-Rupture, Overstressing and a Proposed New Methodology to Assess the Durability and Reliability of Ceramic Matrix Composites at Elevated Temperatures (open access)

Stress-Rupture, Overstressing and a Proposed New Methodology to Assess the Durability and Reliability of Ceramic Matrix Composites at Elevated Temperatures

A new testing strategy is proposed to assess the durability and reliability of non- oxide continuous fiber-reinforced ceramic composites for high temperature structural applications. The strategy is based on determining the reliability (probability of failure) of these materials when subjected to random loading schedules consisting of load and temperature spikes that are superimposed on otherwise constant stress and temperature histories. The frequency and magnitude of the load and temperature spikes would be representative of the number and characteristics of the transients that are associated with a particular industrial application and that are expected to occur over the life of the component. The effect of overstressing on the stress- ruptttre behavior of a CG-NicalonTM fiber-reinforced SiC composite was investigated and results arc presented from tests conducted in ambient air at 950"C.
Date: July 5, 1999
Creator: Lara-Curzio, E.
System: The UNT Digital Library
An Investigation of Tendon Corrosion-Inhibitor Leakage into Concrete (open access)

An Investigation of Tendon Corrosion-Inhibitor Leakage into Concrete

During inspections performed at US nuclear power plants several years ago, some of the prestressed concrete containment had experienced leakage of the tendon sheathing filler. A study was conducted to indicate the extent of the leakage into the concrete and its potential effects on concrete properties. Concrete core samples were obtained from the Trojan Nuclear Plant. Examination and testing of the core samples indicated that the appearance of tendon sheathing filler on the surface was due to leakage of the filler from the conduits and its subsequent migration to the concrete surface through cracks that were present. Migration of the tendon sheathing filler was confined to the cracks with no perceptible movement into the concrete. Results of compressive strength tests indicated that the concrete quality was consistent in the containment and that the strength had increased relative to the strength at 28 days age.
Date: July 5, 1999
Creator: Costello, J. F.; Naus, D. J. & Oland, C. B.