Permanent magnet sextupole protocol and tolerances for the damping rings (open access)

Permanent magnet sextupole protocol and tolerances for the damping rings

Response is given to various questions on alignment tolerances for the permanent magnet sextupoles (PMS's) in the damping rings. Consideration is given to rotational errors, strength/longitudinal placement errors, transverse placement errors, pitch/yaw or tilt errors, and harmonic field errors. Resulting error limits can be specified in terms of the maximum errors allowed in the distribution. (LEW)
Date: September 5, 1985
Creator: Spencer, J.E.
System: The UNT Digital Library