Research on CdZnTe and Other Novel Room Temperature Gamma Ray Spectrometer Materials (open access)

Research on CdZnTe and Other Novel Room Temperature Gamma Ray Spectrometer Materials

Room temperature gamma-ray spectrometers are being developed for a number of years for national security applications where high sensitivity, low operating power and compactness are indispensable. The technology has matured now to the point where large volume (several cubic centimeters) and high energy resolution (approximately 1% at 660 eV) of gamma photons, are becoming available for their incorporation into portable systems for remote sensing of signatures from nuclear materials.
Date: May 5, 2007
Creator: Burger, Arnold; Groza, Michael; Cui, Yunlong; Roy, Utpal N. & Guo, M.
System: The UNT Digital Library
Studies of dynamic properties of shock compressed single crystals by in situ dynamic x-ray diffraction and sample recovery (open access)

Studies of dynamic properties of shock compressed single crystals by in situ dynamic x-ray diffraction and sample recovery

Laser compression provides pressures ranging from a few to hundreds of GPa at pulse durations of the order of nanoseconds or fractions thereof. The short duration ensures a rapid decay of the pulse and quenching of shocked sample in times that are orders of magnitude lower than in conventional explosively driven plate impact experiments. Systematic experiments carried out in specimens well suited for transmission electron microscopy characterization are revealing that laser compression, by virtue of a much more rapid cooling, enables the retention of a deformation structure closer to the one existing during shock. The smaller pulse length decreases the propensity for localization. Copper and copper aluminum (2 and 6 wt% Al) with orientations [001] and [ ] were subjected to high intensity laser pulses with energy levels of 70 to 300 J delivered in a pulse duration of approximately 3 ns. Systematic differences of the defect substructure were observed as a function of pressure and stacking fault energy. The changes in the mechanical properties for each condition were compared using micro- and nano-hardness measurements and correlated well with observations of the defect substructure. Three regimes of plastic deformation were identified and their transitions modeled: dislocation cells, stacking faults, and …
Date: May 5, 2007
Creator: Meyers1, M. A.; Schneider, M. S.; Jarmakani, H.; Kad, B.; Remington2, B. A.; Kalantar, D. H. et al.
System: The UNT Digital Library
INTERIM REPORT FOR HANFORD TANKS AY-102 & AP-101 EFFECT OF CHEMISTRY & OTHER VARIABLES ON CORROSION & STRESS CORROSION CRACKING (open access)

INTERIM REPORT FOR HANFORD TANKS AY-102 & AP-101 EFFECT OF CHEMISTRY & OTHER VARIABLES ON CORROSION & STRESS CORROSION CRACKING

The objective of this work is to determine the range of conditions where the tank steel is susceptible to localized corrosion and SCC in simulants for waste in tanks AY-102 and AP-101.
Date: May 5, 2007
Creator: HARTY, W.M.
System: The UNT Digital Library