Serial/Series Title

4 Matching Results

Results open in a new window/tab.

Evaluation of Fretting Corrosion of ZR-2 (open access)

Evaluation of Fretting Corrosion of ZR-2

Although the corrosion of resistance of Zircaloy--2 clad fuel elements in high temperature water is excellent, some concern has been expressed in regard to the resistance against fretting corrosion. Since this form of corrosion can proceed quite rapidly it could induce fuel element failure through penetration of the cladding. Fretting corrosion if it occurred, would take place either where the fuel element contacted the process tube or where portions of the fuel element contacted each other, e. g. wire-wrapping around a cluster of cylindrical fuel rods. This form of corrosion is defined as corrosion occurring at contact areas and as such, fretting of Zircaloy-2 could take place in many reactor concepts. This report details the results of testing performed to induce fretting corrosion of Zircaloy-2 and the direction of the future tests.
Date: February 5, 1960
Creator: Lobsinger, R. J.
System: The UNT Digital Library
KAPL-120-8A Test Assembly Thermocouple Failure. (open access)

KAPL-120-8A Test Assembly Thermocouple Failure.

This document reports the circumstances surrounding the failure of sheathed thermocouples during a test being conducted in the KAPL-120 Loop. The report is prepared to provide a record of these events and to acquaint those who use these thermocouples for testing of other applications with the difficulties that are sometimes encountered.
Date: February 5, 1960
Creator: Dearing, F. E.
System: The UNT Digital Library
Neutron Diffusion and Random Walk (open access)

Neutron Diffusion and Random Walk

The following report analyzes random walks and whether or not they can be used to shed any light on problems of neutron diffusion.
Date: February 5, 1953
Creator: Duvall, G. E.
System: The UNT Digital Library
Correlation of Chemical Analyses on Graphite Bars and Test Pile Results (open access)

Correlation of Chemical Analyses on Graphite Bars and Test Pile Results

From abstract: "The chemical analyses of graphite test bars obtained from National Carbon Company and the analyses performed by the Hanford Works Laboratories Division do not correlate significantly with the test pile results, nor do the chemical analyses obtained from National Carbon Company agree with those done in the Handford Works Laboratories. Chemical results obtained at Hanford on samples taken lengthwise from individual bars correlated significantly with the individual test pile results."
Date: February 5, 1948
Creator: Lane, J. J.
System: The UNT Digital Library