The Direct Reading Height Gage and its Applications to Inspection Work : Model 1 and Model 2 (open access)

The Direct Reading Height Gage and its Applications to Inspection Work : Model 1 and Model 2

The direct reading height gauge is a new and fast operating instrument designed primarily for checking hole patterns, but it can also be used for a number of other purposes as well. This report gives a brief review of what the gauge is, what it will do, and how it is operated. Speed and the elimination of most of the sources of error are its chief attributes.
Date: December 1, 1953
Creator: Shew, P. W.
System: The UNT Digital Library
Note on the Numerical Evaluation of Integrals of the Form anti l*SUB infinity/*SUP infinity/ f(x) *phi/(x) dx, with Particular Reference to the Determination of the Expectation of a Function of a Normally Distributed Random Variable (open access)

Note on the Numerical Evaluation of Integrals of the Form anti l*SUB infinity/*SUP infinity/ f(x) *phi/(x) dx, with Particular Reference to the Determination of the Expectation of a Function of a Normally Distributed Random Variable

This note is concerned with the numerical integration of the integrals of the form anti l*SUB infinity/*SUP infinity/ f(x) *phi/(x) dx is "smooth."
Date: September 1, 1953
Creator: unknown
System: The UNT Digital Library
The Use and Calibration of Scintillation Counter--Model Y (open access)

The Use and Calibration of Scintillation Counter--Model Y

Several improvements have been made in the gamma scintillation counter (GSC). The Model V gamma scintillation counter uses a canned thallium activated sodium iodide crystal as a detector. Although the electronic components remain unchanged, a modification of the sample support has been made to improve reproducibility of geometry. To assure comparable results between various counters, they must be operated at the same energy threshold and counting yield. Methods have been developed to assure operation at a preferred energy threshold of 0.1 Mev and an arbitrarily fixed counting yield of 3.36% for Cs-Ba-137. Partial pulse height discrimination against U 237 is also accomplished.
Date: August 1, 1953
Creator: Brauer, F. P. & Leboeuf, M. B.
System: The UNT Digital Library
Physical Properties of Tributylphosphate-Diluent Solutions (open access)

Physical Properties of Tributylphosphate-Diluent Solutions

In connection with the study of aqueous-tributyIphosphate (TBP) systems, the study of the interactions of various diluents with the TBP has been extended. The diluents used were mineral oil, Amsco 125-90W, dodecane, n-hexane, cyclohexane, benzene, n-octyl bromide, carbon tetrachloride, chloroform and pentachloroethane. The solubility of TBP in water from solutions of these diluents and the solubility of water in the organic phase was determined. For the paraffin hydrocarbons as diluents the solubility of TBP in water was found to increase with increasing molal volume of the diluent. No evidence for the formation of TBP-water complex of simple mole ration was found.
Date: September 1, 1953
Creator: Johnson, W. F. & Dillon, R. L.
System: The UNT Digital Library
A Continuous Gamma Activity Monitor for the Product Stream of the Uranium Recovery Plant (open access)

A Continuous Gamma Activity Monitor for the Product Stream of the Uranium Recovery Plant

A continuous gamma-monitoring instrument capable of measuring the activity of the product of the Uranium Recovery plant has been developed and applied under process conditions. It has a detection limit of 15% and a normal range of up 1000% of the activity of natural uranium. Activity measurements made with this instrument have shown good correlation with laboratory determinations and are contributing to improved control of the solvent extraction process.
Date: October 1, 1953
Creator: Leboeuf, M. B.; Connally, R. E. & Upson, U. L.
System: The UNT Digital Library
Microtitration of Free Acid in Uranyl Nitrate Solutions (open access)

Microtitration of Free Acid in Uranyl Nitrate Solutions

The approaches to the solution of the problem of removing or nullifying the effect of the hydrolysis of uranyl ion on acid titrations were: 1) use of a complexing agent and titration technique suitable for micro samples; 2) addition of a reagent that reacts with uranium to release 1 or 2 equivalents of acid per mole of uranium present (this permits correcting the titration value for the acid contributed by the uranium, or conversely permits an alkimetric titration of uranium); 3) separation of the uranium and acid with subsequent titration of the acid; and 4) direct titration of the sample with base. All these approaches yielded at least one method suitable for titrating acid in micro samples of uranium nitrate solutions.
Date: October 1, 1953
Creator: Carson, W. N., Jr.
System: The UNT Digital Library
The Ratio of Plutonium 239 to Uranium 235 Fission Cross Sections from 0.020 to 1.0 Electron Volts (open access)

The Ratio of Plutonium 239 to Uranium 235 Fission Cross Sections from 0.020 to 1.0 Electron Volts

Foils of plutonium 239 and uranium 235 have been mounted back to back in a dual ionization fission chamber in the diffracted beam of the Hanford neutron crystal spectrometer. A quantity proportional to the ration of fission cross sections of Pu239 to U235 has been measured as a function of neutron energy from 0.020 to 1.0 electron volts. The results of this investigation are presented graphically in the text.
Date: December 1, 1953
Creator: Leonard, B. R., Jr.; Hauser, S. M. & Seppi, E. J.
System: The UNT Digital Library
Dynamics of the Supercritical Water Reactor (open access)

Dynamics of the Supercritical Water Reactor

From introduction: "The work described in this report was carried out as part of the feasibility study (ORNL-117) of a supercritical water reactor (SCWR) for use in nuclear propulsion of aircraft. The object of this work was to study the dynamic behavior of a particular design of supercritical water reactor. Numerical results are presented in Appendix I."
Date: February 1, 1953
Creator: Goertzel, Gerald, 1919-; Shapiro, Mathew M. & Soodak, Harry
System: The UNT Digital Library
Operation and Maintenance Instructions for Gamma Scintillation Monitor - Model 3 (open access)

Operation and Maintenance Instructions for Gamma Scintillation Monitor - Model 3

Gamma scintillation monitor Model 3 is designed to continuously monitor and record the gamma activity of a process solution.
Date: October 1, 1953
Creator: Connally, R. E.
System: The UNT Digital Library
Non-Overload Amplifiers (open access)

Non-Overload Amplifiers

Report issued by the Brookhaven National Laboratory discussing non-overload amplifiers, including features, performance, and improvements of amplifiers. This report includes illustrations, and photographs, as well as errata at the end of the report.
Date: April 1, 1953
Creator: Higinbotham, W. A.
System: The UNT Digital Library