Abstract: "Thirty-four uranium ingots containing controlled amounts of carbon, nitrogen, and Mgl2 slag were cast, rolled, and examined to investigate the relation between these impurities and the quality of the rolled rod. Carbon in concentrations up to 1400 ppm and nitrogen up to 170 ppm, either singly or in combination, had no significant effect on the number of defects observed in the rolled rod. The quality of the rods, however decreased with increasing amount of slag necessary to cause observable differences in the rod could not be detected on analysis, but was visible in the microstructure."
Date: October 1, 1954
Creator: Saller, Henry A.; Keeler, J. R. & Cuddy, L. J.