9 Matching Results

Results open in a new window/tab.

Federal government provision of public information: issues related to public access, technology, and laws/regulations: for Government Information Technology Project, Communications and Information Technology Program, (open access)

Federal government provision of public information: issues related to public access, technology, and laws/regulations: for Government Information Technology Project, Communications and Information Technology Program,

This report discusses government (public) information, both published and unpublished, which Federal Government either does or does not make public."Public information", is collected and/or developed at Government expenses or as required by public law, and not considered to be classified, personal, or otherwise subject to exemption from the Freedom of Information Act or the Privacy Act.
Date: December 28, 1984
Creator: McClure, Charles R.
System: The UNT Digital Library
Final report to the Office of Technology Assessment on agency profiles of civil liberties practices, from the KBL Group, Inc. (open access)

Final report to the Office of Technology Assessment on agency profiles of civil liberties practices, from the KBL Group, Inc.

This report presents the results of an empirical study which profiles the information and technology practices of seven federal agencies/programs as they relate to three civil liberties areas: the collection of personal or company information; the provision of public information; and access to agency decision-making.
Date: December 28, 1984
Creator: Levitan, Karen B.; Barth, Patrica D. & Griffin Shook, Diane
System: The UNT Digital Library
East Mesa geothermal pump test facility (EMPTF). Final report (open access)

East Mesa geothermal pump test facility (EMPTF). Final report

The design, fabrication and installation of a geothermal pump test facility (EMPFT) at the DOE geothermal site at East Mesa, California which is capable of testing 70 to 750 horsepower downwell pumps in a controlled geothermal environment were completed. The facility consists of a skid-mounted brine control module, a 160 foot below test well section, a hydraulic turbine for power recovery, a gantry-mounted hoist for pump handling and a 3-phase, 480 VAC, 1200 amp power supply to handle pump electric requirements. Geothermal brine is supplied to the EMPTF from one of the facility wells at East Mesa. The EMPTF is designed with a great amount of flexibility. The 20-inch diameter test well can accommodate a wide variety of pumps. The controls are interactive and can be adjusted to obtain a full complement of pump operation data, or set to maintain constant conditions to allow long-term testing with a minimum of operator support. The hydraulic turbine allows the EMPTF user to recover approximately 46% of the input pump power to help defray the operating cost of the unit. The hoist is provided for material handling and pump servicing and reduces the equipment that the user must supply for pump installation, inspection …
Date: November 28, 1984
Creator: Olander, R.G. & Roberts, G.K.
System: The UNT Digital Library
East Mesa geothermal pump test facility (EMPTF). Final report (open access)

East Mesa geothermal pump test facility (EMPTF). Final report

Barber-Nichols has completed the design, fabrication and installation of a geothermal pump test facility at the DOE geothermal site at East Mesa, California which is capable of testing 70 to 750 horsepower downwell pumps in a controlled geothermal environment. The facility consists of a skid-mounted brine control module, a 160 foot below ground test well section, a hydraulic turbine for power recovery, a gantry-mounted hoist for pump handling and a 3-phase, 480 VAC, 1200 amp power supply to handle pump electric requirements. Geothermal brine is supplied to the EMPTF from one of the facility wells at East Mesa. The EMPTF is designed with a great amount of flexibility to attract the largest number of potential users. The 20-inch diameter test well can accommodate a wide variety of pumps. The controls are interactive and can be adjusted to obtain a full complement of pump operation data, or set to maintain constant conditions to allow long-term testing with a minimum of operator support. The hydraulic turbine allows the EMPTF user to recover approximately 46% of the input pump power to help defray the operating cost of the unit. The hoist is provided for material handling and pump servicing and reduces the equipment …
Date: November 28, 1984
Creator: Olander, R.G. & Roberts, G.K.
System: The UNT Digital Library
Mechanical and hydraulic snubbers for nuclear applications, September 1984 (open access)

Mechanical and hydraulic snubbers for nuclear applications, September 1984

This standard covers the material, design, analysis, application, fabrication, testing, examination, quality assurance, certification, delivery, installation and inservice inspection of safety-related hydraulic and mechanical shock suppressors (snubbers) for nuclear reactors. These devices permit thermal expansion motion of components during normal plant service, but provide restraint to dynamic loads.
Date: September 28, 1984
Creator: unknown
System: The UNT Digital Library
The Stationary RF Bucket (open access)

The Stationary RF Bucket

None
Date: August 28, 1984
Creator: H., Hahn
System: The UNT Digital Library
Inspection of the Heber binary-cycle geothermal project (open access)

Inspection of the Heber binary-cycle geothermal project

We concluded that DOE had effective management control procedures to monitor project costs and the design, construction and demonstration activities. Lessons learned from previous DOE geothermal projects were applied and technical information generated from the Heber plant will be transferred to the public and private sectors by the project participants. We also identified the following issues that concerned us: Revenue Sharing: under existing revenue sharing provisions in the Cooperative Agreement, we estimate that reimbursable revenues to DOE will range between $30.5 million and $51.6 million. DOE and the public should be reimbursed for the total contribution of $61 million because the plant, if commercialized, will primarily benefit ratepayers and stockholders of San Diego Gas and Electric Company (SDG and E); Project Office Support Contracts: Our analyses of a number of project office support contracts suggest that some of this work should be cost shared with SDG and E; in other cases, the value of the work is questionable and appears to be an unnecessary expenditure of DOE funds; and Questionable Contractor Procurement: the noncompetitive procurement of a private firm to develop an economic study of a second Heber plant appears to be unjustified and duplicates work already planned by project …
Date: March 28, 1984
Creator: unknown
System: The UNT Digital Library
Periods found in heat measurements obtained by calorimetry (open access)

Periods found in heat measurements obtained by calorimetry

During a span of 640 days, a periodicity of 1.5158 +- 0.0008 days was discovered in successive heater equilibria on Calorimeter No. 127. Measurements were taken at 12-h intervals, with occasional changes of exactly 3 or 6 h in the schedule of measurements. This schedule eliminated all other possible periods except a period of 0.150156 days. Periods of 1.519125 and 1.511283 days were discovered in data on the excess length of day as obtained by the US Naval Observatory over a period of 24 y. These two periods could equally well represent periods of 0.150189 and 0.150112 days, since measurements were obtained only once every 24 h. It is suggested that periods observed in sensitive calorimeters and in length of day data may be related. 1 reference, 6 figures, 5 tables.
Date: February 28, 1984
Creator: Jordan, K. C.
System: The UNT Digital Library
Plasma potential control: initial results from tandem mirror experiment-upgrade (open access)

Plasma potential control: initial results from tandem mirror experiment-upgrade

Initial plasma potential control experiments used plates in the end fan, insulated from the end walls of TMX-U, which mapped along field lines to the plasma core (r/sub c/ less than or equal to 12.9 cm). Measurements in which these plates are shorted to ground during plugging demonstrate that floating the plates increases the buildup rate of the central cell plasma, steepens the core density profile, and affects the plasma throughout the entire cross section. Floating the plates decreases the ion radial transport rate in the core by a factor of at least 1.5. Because of these encouraging results, in the next series of experiments more plates will be added, extending to a larger radius (r/sub c/ less than or equal to 19.4 cm).
Date: February 28, 1984
Creator: Hopper, E.B. Jr.
System: The UNT Digital Library