10 Matching Results

Results open in a new window/tab.

Fusion power: Expected environmental characteristics and status of R and D (open access)

Fusion power: Expected environmental characteristics and status of R and D

From the outset in the 1950's, fusion research has been motivated by environmental concerns as well as long-term fuel supply issues. Compared to fossil fuels both fusion and fission would produce essentially zero emissions to the atmosphere. Compared to fission, fusion reactors should offer high demonstrability of public protection from accidents and a substantial amelioration of the radioactive waste problem. Fusion still requires lengthy development, the earliest commercial deployment being likely to occur around 2025-2050. However, steady scientific progress is being made and there is a wide consensus that it is time to plan large-scale engineering development. A major international effort, called the International Thermonuclear Experimental Reactor (ITER), is being carried out under IAEA auspices to design the world's first fusion engineering test reactor, which could be constructed in the 1990's. 5 figs., 3 tabs.
Date: March 24, 1989
Creator: Fowler, T.K.
System: The UNT Digital Library
400 MeV upgrade for the Fermilab linac (open access)

400 MeV upgrade for the Fermilab linac

Fermilab has plans for a comprehensive accelerator upgrade to open new possibilities for both the fixed target and collider experimental programs. An early step in this program is to increase the energy of the linac from 200 to 400 MeV by replacing the last four of its nine 201 MHz Alvarez tanks with twenty-eight 805 MHz side-coupled cavity chains operating at about 8 MV/m average axial field. The principal purpose is to reduce the incoherent spacecharge tuneshift at injection into the Booster which currently limits both the brightness of the beam, an important determinant of collider luminosity, and total intensity to produce both the antiprotons for the collider and the beams to fixed target experimental areas. Other consequences of higher Booster injection energy expected to contribute to some degree of higher intensity limits and improved operational characteristics include improved quality of the guide field at injection, reduced frequency swing for the rf systems, and smaller emittance for the injected beam. The linac upgrade project has moved from a 1986 study through a development project including structure models and numerical studies to a full-feature module prototyping starting this year.
Date: March 24, 1989
Creator: MacLachlan, J.A.
System: The UNT Digital Library
Electron correlation in the continuum (open access)

Electron correlation in the continuum

We consider a class of problems, notably double ionization, which require accurate descriptions of correlation in both the initial and final states. Methods are presented for representing correlated wavefunctions on a basis spline lattice, and for calculating bound-continuum transition probabilities. 13 refs.
Date: July 24, 1989
Creator: Bottcher, C. & Strayer, M. R.
System: The UNT Digital Library
A structural evaluation of the Shippingport reactor pressure vessel for transport impact conditions (open access)

A structural evaluation of the Shippingport reactor pressure vessel for transport impact conditions

The Shippingport Atomic Power Station in Shippingport, Pennsylvania, is being decommissioned and dismantled. This government-leased property will be returned, in a radiologically safe condition, to its owner. All radioactive material is being removed from the Shippingport Station and transported for burial to the DOE Hanford Reservation in Richland, Washington. The reactor pressure vessel (RPV) will be transported by barge to Hanford. This paper describes an evaluation of the structural response of the RPV to the normal and accident impact test conditions as required by the Code of Federal Regulations. 3 refs., 5 figs., 3 tabs.
Date: March 24, 1989
Creator: Witte, M.C. & Chou, C.K.
System: The UNT Digital Library
Pion induced double-charge exchange above the resonance (open access)

Pion induced double-charge exchange above the resonance

The zero degree excitation function for ({pi}{sup +}, {pi}{sup -}) is calculated for pion energies of 300 to 1400 MeV assuming a sequential mechanism. The cross section around 1225 MeV is 10{sup 4} smaller than at 800 MeV. Experiments at this energy should be ideal for searches for effects due to exchange currents, and other non-conventional mechanisms. 15 refs.
Date: October 24, 1989
Creator: Oset, E.; Strottman, D. (Valencia Univ. (Spain). Dept. de Fisica Teorica & Los Alamos National Lab., NM (USA))
System: The UNT Digital Library
Multiple electron capture in close ion-atom collisions (open access)

Multiple electron capture in close ion-atom collisions

Collisions in which a fast highly charged ion passes within the orbit of K electron of a target gas atom are selected by emission of a K x-ray from the projectile or target. Measurement of the projectile charge state after the collision, in coincidence with the K x-ray, allows measurement of the charge-transfer probability during these close collisions. When the projectile velocity is approximately the same as that of target electrons, a large number of electrons can be transferred to the projectile in a single collision. The electron-capture probability is found to be a linear function of the number of vacancies in the projectile L shell for 47-MeV calcium ions in an Ar target. 18 refs., 9 figs.
Date: July 24, 1989
Creator: Schlachter, A. S.; Stearns, J. W.; Berkner, K. H.; Bernstein, E. M.; Clark, M. W.; DuBois, R. D. et al.
System: The UNT Digital Library
Epithermal beam development at the BMRR (Brookhaven Medical Research Reactor): Dosimetric evaluation (open access)

Epithermal beam development at the BMRR (Brookhaven Medical Research Reactor): Dosimetric evaluation

The utilization of an epithermal neutron beam for neutron capture therapy (NCT) is desirable because of the increased tissue penetration relative to a thermal neutron beam. Over the past few years, modifications have been and continue to be made at the Brookhaven Medical Research Reactor (BMRR) by changing its filter components to produce an optimal epithermal beam. An optimal epithermal beam should contain a low fast neutron contamination and no thermal neutrons in the incident beam. Recently a new moderator for the epithermal beam has been installed at the epithermal port of the BMRR and has accomplished this task. This new moderator is a combination of alumina (Al{sub 2}O{sub 3}) bricks and aluminum (Al) plates. A 0.51 mm thick cadmium (Cd) sheet has reduced the thermal neutron intensity drastically. Furthermore, an 11.5 cm thick bismuth (Bi) plate installed at the port surface has reduced the gamma dose component to negligible levels. Foil activation techniques have been employed by using bare gold and cadmium-covered gold foil to determine thermal as well as epithermal neutron fluence. Fast neutron fluence has been determined by indium foil counting. Fast neutron and gamma dose in soft tissue, free in air, is being determined by the …
Date: August 24, 1989
Creator: Saraf, S. K.; Fairchild, R. G.; Kalef-Ezra, J.; Laster, B. H.; Fiarman, S. & Ramsey, E.
System: The UNT Digital Library
Time-Dependent Two-Dimensional Radiation Hydrodynamics of Accreting Matter Onto Highly Magnetized Neutron Stars (open access)

Time-Dependent Two-Dimensional Radiation Hydrodynamics of Accreting Matter Onto Highly Magnetized Neutron Stars

We present for the first time, the self-consistent solution of the two-dimensional, time-dependent equations of radiation-hydrodynamics governing the accretion of matter onto the highly magnetized polar caps of luminous x-ray pulsars. The calculations show a structure in the accretion column very different from previous one-zone uniform models. We have included all the relevant magnetic field corrections to both the hydrodynamics and the radiative transport. We include a new theory for the diffusion and advection of both radiation energy density and photon number density. For initially uniformly accreting models with super-Eddington flows, we have uncovered evidence of strong radiation-driven outflowing optically thin radiation filled regions of the accretion column embedded in optically-thick inflowing plasma. The development of these photon bubbles'' have growth times on the order of a millisecond and show fluctuations on sub-millisecond timescales. The photon bubbles are likely to be a consequence of convective over-stability and may result in observable fluctuations in the emitted luminosity leading to luminosity dependent changes in the pulse profile. This may provide important new diagnostics for conditions in accreting x-ray pulsars. 13 refs., 18 figs.
Date: November 24, 1989
Creator: Klein, R.I. (California Univ., Los Angeles, CA (USA). Dept. of Astronomy Lawrence Livermore National Lab., CA (USA) California Univ., Los Angeles, CA (USA). Inst. of Geophysics and Planetary Physics) & Arons, J. (California Univ., Berkeley, CA (USA). Dept. of Astronomy California Univ., Los Angeles, CA (USA). Inst. of Geophysics and Planetary Physics CEA Centre d'Etudes Nucleaires de Saclay, 91 -
System: The UNT Digital Library
Design and Testing of a Superfluid Liquid Helium CoolingLoop (open access)

Design and Testing of a Superfluid Liquid Helium CoolingLoop

This paper describes the design and preliminary testing of a cryogenic cooling loop that uses a thermomechanical pump to circulate superfluid liquid helium. The cooling loop test apparatus is designed to prove forced liquid helium flow concepts that will be used on the Astromag superconducting magnet facility.
Date: July 24, 1989
Creator: Gavin, L. M.; Green, M. A.; Levin, S. M.; Smoot, George F. & Witebsky, C.
System: The UNT Digital Library
Polycyclic Aromatic Hydrocarbon Solute Probes. Part 5: Fluorescence Spectra of Pyrene, Ovalene, Coronene, and Benzo[ghi]perylene Dissolved in Liquid Alkylammonium Thiocyanate Organic Salts (open access)

Polycyclic Aromatic Hydrocarbon Solute Probes. Part 5: Fluorescence Spectra of Pyrene, Ovalene, Coronene, and Benzo[ghi]perylene Dissolved in Liquid Alkylammonium Thiocyanate Organic Salts

Article on polycyclic aromatic hydrocarbon solute probes and fluorescence spectra of pyrene, ovalene, coronene, and benzo[ghi]perylene dissolved in liquid alkylammonium thiocyanate organic salts.
Date: February 24, 1989
Creator: Street, Kenneth W.; Acree, William E. (William Eugene); Fetzer, John Charles, 1953-; Shetty, Prabhakara H. & Poole, Colin F.
System: The UNT Digital Library