Resource Type

4 Matching Results

Results open in a new window/tab.

Laser Fusion Experiments at KMS (open access)

Laser Fusion Experiments at KMS

None
Date: April 13, 1982
Creator: Storm, E. K.
System: The UNT Digital Library
SEBREZ: an inertial-fusion-reactor concept (open access)

SEBREZ: an inertial-fusion-reactor concept

The neutronic aspects of an inertial fusion reactor concept that relies on asymmetrical neutronic effects to enhance the tritium production in the breeding zones have been studied. We find that it is possible to obtain a tritium breeding ratio greater than 1.0 with a chamber configuration in which the breeding zones subtend only a fraction of the total solid angle. This is the origin of the name SEBREZ which stands for SEgregated BREeding Zones. It should be emphasized that this is not a reactor design study; rather this study illustrates certain neutronic effects in the context of a particular reactor concept. An understanding of these effects forms the basis of a design technique which has broader application than just the SEBREZ concept.
Date: January 13, 1982
Creator: Meier, W. R.
System: The UNT Digital Library
Open grid vs mesh grid as the extraction field structure in a streak camera image-converter tube (open access)

Open grid vs mesh grid as the extraction field structure in a streak camera image-converter tube

It is concluded that the dynamic range of a streak tube does not depend on whether it uses a fine-mesh or an open structure to provide the extraction field. An RCA C-73435 streak tube body was fitted with two extraction grid structures by replacing the conventional open grid with a steel plate containing two apertures. One aperture simulated the open grid structure; the other was a 2 x 20 mm slit covered with a fine mesh (40 wires per mm, 38% transmissive). The apertures were equal distances above and below the tube axis. Using 35-ps pulses, dynamic range curves were taken at 1.06 ..mu..m on one aperture at a time, while blocking the other aperture. As we anticipated, the tube saturated at nearly the same point for the open and mesh apertures. The noise levels for both apertures were almost equal and very close to the film fog level. Noise level was lower than for earlier measurements on other makes of tubes with a fine-mesh grid. The dynamic range for both apertures was in the order of 6000, which indicates that the lower dynamic range of other tubes must be due to something other than the use of a fine-mesh …
Date: May 13, 1982
Creator: Thomas, S. W. & Peterson, R. L.
System: The UNT Digital Library
MPS II drift-chamber system (open access)

MPS II drift-chamber system

A new system of detectors (MPS II) which has been installed and operated in the Brookhaven National Laboratory Multiparticle Spectrometer (MPS), consisting of short drift distance drift chambers is briefly described. (WHK)
Date: May 13, 1982
Creator: Etkin, A.; Eiseman, S. & Foley, K.J.
System: The UNT Digital Library