0.351 micron Laser Beam propagation in High-temperature Plasmas (open access)

0.351 micron Laser Beam propagation in High-temperature Plasmas

A study of the laser-plasma interaction processes have been performed in plasmas that are created to emulate the plasma conditions in indirect drive inertial confinement fusion targets. The plasma emulator is produced in a gas-filled hohlraum; a blue 351-nm laser beam propagates along the axis of the hohlraum interacting with a high-temperature (T{sub e} = 3.5 keV), dense (n{sub e} = 5 x 10{sup 20}cm{sup -3}), long-scale length (L {approx} 2 mm) plasma. Experiments at these conditions have demonstrated that the interaction beam produces less than 1% total backscatter resulting in transmission greater than 90% for laser intensities less than I < 2 x 10{sup 15} W-cm{sup -2}. The bulk plasma conditions have been independently characterized using Thomson scattering where the peak electron temperatures are shown to scale with the hohlraum heater beam energy in the range from 2 keV to 3.5 keV. This feature has allowed us to determine the thresholds for both backscattering and filamentation instabilities; the former measured with absolutely calibrated full aperture backscatter and near backscatter diagnostics and the latter with a transmitted beam diagnostics. A plasma length scaling is also investigated extending our measurements to 4-mm long high-temperature plasmas. At intensities I < 5 x …
Date: December 10, 2007
Creator: Froula, D.; Divol, L.; Meezan, N.; Ross, J.; Berger, R. L.; Michel, P. et al.
Object Type: Report
System: The UNT Digital Library
1,2- Hydroxypyridonates as Contrast Agents for Magnetic ResonanceImaging: TREN-1,2-HOPO (open access)

1,2- Hydroxypyridonates as Contrast Agents for Magnetic ResonanceImaging: TREN-1,2-HOPO

1,2-Hydroxypyridinones (1,2-HOPO) form very stable lanthanide complexes that may be useful as contrast agents for Magnetic Resonance Imaging (MRI). X-ray diffraction of single crystals established that the solid state structures of the Eu(III) and the previously reported [Inorg. Chem. 2004, 43, 5452] Gd(III) complex are identical. The recently discovered sensitizing properties of 1,2-HOPO chelates for Eu(III) luminescence allow direct measurement of the number if water molecules in the metal complex. Fluorescence measurements of the Eu(III) complex corroborate that in solution two water molecules coordinate the lanthanide (q = 2) as proposed from the analysis of NMRD profiles. In addition, fluorescence measurements have verified the anion binding interactions of lanthanide TREN-1,2-HOPO complexes in solution, studied by relaxivity, revealing only very weak oxalate binding (K{sub A} = 82.7 {+-} 6.5 M{sup -1}). Solution thermodynamic studies of the metal complex and free ligand have been carried out using potentiometry, spectrophotometry and fluorescence spectroscopy. The metal ion selectivity of TREN-1,2-HOPO supports the feasibility of using 1,2-HOPO ligands for selective lanthanide binding [pGd = 19.3 (2); pZn = 15.2 (2), pCa = 8.8 (3)].
Date: May 8, 2007
Creator: Jocher, Christoph J.; Moore, Evan G.; Xu, Jide; Avedano, Stefano; Botta, Mauro; Aime, Silvio et al.
Object Type: Article
System: The UNT Digital Library
2\beta + \gamma from B^0 to D^\mp K^0 \pi^\pm Decays at BaBar: aSimulation Study (open access)

2\beta + \gamma from B^0 to D^\mp K^0 \pi^\pm Decays at BaBar: aSimulation Study

The authors present the results of a simulation study to perform the extraction of 2{beta} + {gamma} from B{sup 0} {yields} D{sup {-+}}K{sup 0}{pi}{sup {+-}} decays through a time-dependent Dalitz analysis of BaBar data.
Date: April 16, 2007
Creator: Polci, Francesco; Schune, Marie-Helene; Stocchi, Achille & /Orsay, LAL
Object Type: Article
System: The UNT Digital Library
3.9 GHz superconducting accelerating 9-cell cavity vertical test results (open access)

3.9 GHz superconducting accelerating 9-cell cavity vertical test results

The 3rd harmonic 3.9GHz accelerating cavity was proposed to improve the beam performance of the FLASH (TTF/DESY) facility [1]. In the frame of a collaborative agreement, Fermilab will provide DESY with a cryomodule containing a string of four cavities. In addition, a second cryomodule with one cavity will be fabricated for installation in the Fermilab photo-injector, which will be upgraded for the ILC accelerator test facility. The first 9-cell Nb cavities were tested in a vertical setup and they didn't reach the designed accelerating gradient [2]. The main problem was a multipactor in the HOM couplers, which lead to overheating and quenching of the HOM couplers. New HOM couplers with improved design are integrated in the next 9-cell cavities. In this paper we present all results of the vertical tests.
Date: June 1, 2007
Creator: Khabiboulline, Timergali; Cooper, Charles; Dhanaraj, Nandhini; Edwards, Helen; Foley, Mike; Harms, Elvin et al.
Object Type: Article
System: The UNT Digital Library
3.9 GHz superconducting accelerating 9-cell cavity vertical test results (open access)

3.9 GHz superconducting accelerating 9-cell cavity vertical test results

None
Date: June 1, 2007
Creator: Khabiboulline, Timergali; Cooper, Charles; Dhanaraj, Nandhini; Edwards, Helen; Foley, Mike; Harms, Elvin et al.
Object Type: Article
System: The UNT Digital Library
3-D sedimentological and geophysical studies of clastic reservoir analogs: Facies architecture, reservoir properties, and flow behavior within delta front facies elements of the Cretaceous Wall Creek Member, Frontier Formation, Wyoming (open access)

3-D sedimentological and geophysical studies of clastic reservoir analogs: Facies architecture, reservoir properties, and flow behavior within delta front facies elements of the Cretaceous Wall Creek Member, Frontier Formation, Wyoming

This project examined the internal architecture of delta front sandstones at two locations within the Turonian-age Wall Creek Member of the Frontier Formation, in Wyoming. The project involved traditional outcrop field work integrated with core-data, and 2D and 3D ground penetrating radar (GPR) imaging from behind the outcrops. The fluid-flow engineering work, handled through a collaborative grant given to PI Chris White at LSU, focused on effects on fluid flow of late-stage calcite cement nodules in 3D. In addition to the extensive field component, the work funded 2 PhD students (Gani and Lee) and resulted in publication of 10 technical papers, 17 abstracts, and 4 internal field guides. PI Bhattacharya also funded an additional 3 PhD students that worked on the Wall Creek sandstone funded separately through an industrial consortium, two of whom graduated in the fall 2006 ((Sadeque and Vakarelov). These additional funds provided significant leverage to expand the work to include a regional stratigraphic synthesis of the Wall Creek Member of the Frontier Formation, in addition to the reservoir-scale studies that DOE directly funded. Awards given to PI Bhattacharya included the prestigious AAPG Distinguished Lecture Award, which involved a tour of about 25 Universities and Geological Societies in …
Date: February 16, 2007
Creator: Bhattacharya, Janok P. & McMechan, George A.
Object Type: Report
System: The UNT Digital Library
The 4.8 GHz LHC Schottky pick-up system (open access)

The 4.8 GHz LHC Schottky pick-up system

The LHC Schottky observation system is based on traveling wave type high sensitivity pickup structures operating at 4.8 GHz. The choice of the structure and operating frequency is driven by the demanding LHC impedance requirements, where very low impedance is required below 2 GHz, and good sensitivity at the selected band at 4.8 GHz. A sophisticated filtering and triple down -mixing signal processing chain has been designed and implemented in order to achieve the specified 100 dB instantaneous dynamic range without range switching. Detailed design aspects for the complete systems and test results without beam are presented and discussed.
Date: June 1, 2007
Creator: Caspers, Fritz; Jimenez, Jose Miguel; Jones, Rhodri Owain; Kroyer, Tom; Vuitton, Christophe; Hamerla, Timothy W. et al.
Object Type: Article
System: The UNT Digital Library
4-D High-Resolution Seismic Reflection Monitoring of Miscible CO2 Injected into a Carbonate Reservoir (open access)

4-D High-Resolution Seismic Reflection Monitoring of Miscible CO2 Injected into a Carbonate Reservoir

The objective of this research project was to acquire, process, and interpret multiple high-resolution 3-D compressional wave and 2-D, 2-C shear wave seismic data in the hopes of observing changes in fluid characteristics in an oil field before, during, and after the miscible carbon dioxide (CO{sub 2}) flood that began around December 1, 2003, as part of the DOE-sponsored Class Revisit Project (DOE No.DE-AC26-00BC15124). Unique and key to this imaging activity is the high-resolution nature of the seismic data, minimal deployment design, and the temporal sampling throughout the flood. The 900-m-deep test reservoir is located in central Kansas oomoldic limestones of the Lansing-Kansas City Group, deposited on a shallow marine shelf in Pennsylvanian time. After 30 months of seismic monitoring, one baseline and eight monitor surveys clearly detected changes that appear consistent with movement of CO{sub 2} as modeled with fluid simulators and observed in production data. Attribute analysis was a very useful tool in enhancing changes in seismic character present, but difficult to interpret on time amplitude slices. Lessons learned from and tools/techniques developed during this project will allow high-resolution seismic imaging to be routinely applied to many CO{sub 2} injection programs in a large percentage of shallow carbonate …
Date: June 30, 2007
Creator: Miller, Richard D.; Raef, Abdelmoneam E.; Byrnes, Alan P. & Harrison, William E.
Object Type: Report
System: The UNT Digital Library
04-ERD-052-Final Report (open access)

04-ERD-052-Final Report

Generating the sequence of the human genome represents a colossal achievement for science and mankind. The technical use for the human genome project information holds great promise to cure disease, prevent bioterror threats, as well as to learn about human origins. Yet converting the sequence data into biological meaningful information has not been immediately obvious, and we are still in the preliminary stages of understanding how the genome is organized, what are the functional building blocks and how do these sequences mediate complex biological processes. The overarching goal of this program was to develop novel methods and high throughput strategies for determining the functions of ''anonymous'' human genes that are evolutionarily deeply conserved in other vertebrates. We coupled analytical tool development and computational predictions regarding gene function with novel high throughput experimental strategies and tested biological predictions in the laboratory. The tools required for comparative genomic data-mining are fundamentally the same whether they are applied to scientific studies of related microbes or the search for functions of novel human genes. For this reason the tools, conceptual framework and the coupled informatics-experimental biology paradigm we developed in this LDRD has many potential scientific applications relevant to LLNL multidisciplinary research in bio-defense, …
Date: February 26, 2007
Creator: Loots, G. G.; Ovcharenko, I.; Collette, N.; Babu, P.; Chang, J.; Stubbs, L. et al.
Object Type: Report
System: The UNT Digital Library
8 GeV beam line optics optimization for the rapid antiproton transfers at Fermilab (open access)

8 GeV beam line optics optimization for the rapid antiproton transfers at Fermilab

Tevatron Run-II upgrade requires a significant increase of the efficiency and speed of the antiproton transfers from the Accumulator to the Recycler. The goal for the total transfer time is challenging a reduction from 1 hour down to a few minutes. Here we discuss the beam line optics aspects of this project. Results of lattice measurements and optimization are analyzed in terms of transport efficiency and stability.
Date: February 1, 2007
Creator: Nagaslaev, V.; Lebedev, V.; Morgan, J. & Vander Meulen, D.
Object Type: Article
System: The UNT Digital Library
An 8 GeV H- multi-turn injection system for the Fermilab Main Injector (open access)

An 8 GeV H- multi-turn injection system for the Fermilab Main Injector

An 8 GeV superconducting linear accelerator (SCL) has been proposed [1] as a single stage H{sup -} injector into the Main Injector (MI) synchrotron . This would be the highest energy H{sup -} multi-turn injection system in the world. The conceptual design of an injection system has been further refined by addressing transverse phase space painting issues, chicane dipole fields and foil location, foil temperature issues, and initial longitudinal phase space painting simulations. We present the current state of design.
Date: June 1, 2007
Creator: Johnson, D. E.; Yoon, P.; Liaw, C. J.; Raparia, D. & Bebee-Wang, J.
Object Type: Article
System: The UNT Digital Library
An 8 GeV H- multi-turn injection system for the Fermilab Main Injector (open access)

An 8 GeV H- multi-turn injection system for the Fermilab Main Injector

None
Date: June 1, 2007
Creator: Johnson, D. E.; Yoon, P.; Liaw, C. J.; Raparia, D. & Bebee-Wang, J.
Object Type: Article
System: The UNT Digital Library
10-kJ Status and 100-kJ Future for NIF PetaWatt Technology (open access)

10-kJ Status and 100-kJ Future for NIF PetaWatt Technology

We discuss the status of the NIF ARC, an 8-beam 10-kJ class high-energy petawatt laser, and the future upgrade path of this and similar systems to 100-kJ-class with coherent phasing of multiple apertures.
Date: July 2, 2007
Creator: Siders, C W; Crane, J K; Rushford, M C; Haefner, L C; Hernandez, J E; Dawson, J W et al.
Object Type: Article
System: The UNT Digital Library
14 mrad Extraction Line Optics for Push-Pull (open access)

14 mrad Extraction Line Optics for Push-Pull

The ILC design is based on a single Interaction Region (IR) with 14 mrad crossing angle and two detectors in the 'push-pull' configuration, where the detectors can alternately occupy the Interaction Point (IP). Consequently, the IR optics must be compatible with different size detectors designed for different distance L* between the IP and the nearest quadrupole. This paper presents the push-pull optics for the ILC extraction line compatible with L*= 3.5 m to 4.5 m, and the simulation results of extraction beam loss at 500 GeV CM with detector solenoid.
Date: October 15, 2007
Creator: Nosochkov, Y.; Moffeit, K.; Seryi, A.; Morse, W. & Parker, B.
Object Type: Article
System: The UNT Digital Library
15 KJ FLASH LAMP, POWER CONDITIONING UNIT DESIGNED FOR SAFTY, RELIABILITY & MANUFACTURABILITY* (open access)

15 KJ FLASH LAMP, POWER CONDITIONING UNIT DESIGNED FOR SAFTY, RELIABILITY & MANUFACTURABILITY*

A 15kJoule, Flash Lamp Power Conditioning Unit has been successfully designed, developed, and deployed in the National Ignition Facility (NIF) Preamplifier Modules (PAM). The primary design philosophy of this power conditioning unit (PCU) is safety, reliability, and manufacturability. Cost reduction over commercially equivalent systems was also achieved through an easily manufactured packaging design optimized to meet NIF requirements. While still maintaining low cost, the PCU design includes a robust control system, fault diagnostic system, and safety features. The pulsed power design includes 6 PFN modules, each including a dual series injection trigger transformer, that drive a total of 12 flash lamp loads. The lamps are individually triggered via a 20kV pulse produced by a 1kV, MCT switched capacitive discharge unit on the primary side of the trigger transformer. The remote control interface includes an embedded controller that captures flash lamp current wave forms and fault status for each shot. The embedded controller provides the flexibility of remotely adjusting both the main drive voltage from 1.6 to 2.5 kV and the trigger voltage from 0 to 20 kV.
Date: August 7, 2007
Creator: James, G.; Merritt, B.; Dreifuerst, G.; Strickland, S. & Tse, E.
Object Type: Article
System: The UNT Digital Library
16,000-rpm Interior Permanent Magnet Reluctance Machine with Brushless Field Excitation (open access)

16,000-rpm Interior Permanent Magnet Reluctance Machine with Brushless Field Excitation

The reluctance interior permanent magnet (RIPM) motor is currently used by many leading auto manufacturers for hybrid vehicles. The power density for this type of motor is high compared with that of induction motors and switched reluctance motors. The primary drawback of the RIPM motor is the permanent magnet (PM) because during high-speed operation, the fixed PM produces a huge back electromotive force (emf) that must be reduced before the current will pass through the stator windings. This reduction in back-emf is accomplished with a significant direct-axis (d-axis) demagnetization current, which opposes the PM's flux to reduce the flux seen by the stator wires. This may lower the power factor and efficiency of the motor and raise the requirement on the alternate current (ac) power supply; consequently, bigger inverter switching components, thicker motor winding conductors, and heavier cables are required. The direct current (dc) link capacitor is also affected when it must accommodate heavier harmonic currents. It is commonly agreed that, for synchronous machines, the power factor can be optimized by varying the field excitation to minimize the current. The field produced by the PM is fixed and cannot be adjusted. What can be adjusted is reactive current to the …
Date: October 31, 2007
Creator: Hsu, J. S.; Burress, T. A.; Lee, S. T.; Wiles, R. H.; Coomer, C. L.; McKeever, J.W. et al.
Object Type: Report
System: The UNT Digital Library
16,000-RPM Interior Permanent Magnet Reluctance Machine with Brushless Field Excitation (open access)

16,000-RPM Interior Permanent Magnet Reluctance Machine with Brushless Field Excitation

Introduction to Brushless field excitation(BFE) to overcome the drawbacks of Reluctance Interior Permanent Magnet (RIPM).
Date: October 1, 2007
Creator: Hsu, John S.; Burress, Timothy A.; Lee, Seong T.; Wiles, Randy H.; Coomer, Chester; McKeever, John W. et al.
Object Type: Report
System: The UNT Digital Library
A 96 channel receiver for the ILCTA LLRF system at Fermilab (open access)

A 96 channel receiver for the ILCTA LLRF system at Fermilab

The present configuration of an ILC main LINAC RF station has 26 nine cell cavities driven from one klystron. With the addition of waveguide power coupler monitors, 96 RF signals will be down-converted and processed. A down-converter chassis is being developed that contains 12 eight channel analog modules and a single upconverter module. This chassis will first be deployed for testing a cryomodule composed of eight cavities located at New Muon Laboratory (NML) - Fermilab. Critical parts of the design for LLRF applications are identified and a detailed description of the circuit with various characteristic measurements is presented. The board is composed of an input band-pass filter centered at 1.3GHz, followed by a mixer, which down-converts the cavity probe signal to a proposed 13 MHz intermediate frequency. Cables with 8 channels per connector and good isolation between channels are being used to interconnect each down-converter module with a digital board. As mixers, amplifiers and power splitters are the most sensitive parts for noise, nonlinearities and crosstalk issues, special attention is given to these parts in the design of the LO port multiplication and distribution.
Date: June 1, 2007
Creator: Mavric, Uros; Chase, Brian; Branlard, Julien; Cullerton, Ed & Klepec, Dan
Object Type: Article
System: The UNT Digital Library
100 Area D4 Project Building Completion Report May 2006 - June 2007 (open access)

100 Area D4 Project Building Completion Report May 2006 - June 2007

This report documents the decontamination and decommissioning (D&D) and the demolition of the 153-N, 1515-N, 1516-N, 1517-N, 1518-N, 1519-N, 1331-N, 1332-N, and 181-NC facilities in the 100 Area of the Hanford Site. The D&D and demolition of these facilities included characterization, engineering, removal of hazardous and radiologically contaminated materials, equipment removal, utility disconnection, deactivation, decontamination, demolition of the structure, and removal of the remaining slabs.
Date: July 25, 2007
Creator: Ison, E. G.
Object Type: Report
System: The UNT Digital Library
222-S LABORATORY FUME HOOD TESTING STUDY (open access)

222-S LABORATORY FUME HOOD TESTING STUDY

The 222-S Laboratory contains 155 active fume hoods that are used to support analytical work with radioactive and/or toxic materials. The performance of a fume hood was brought into question after employees detected odors in the work area while mixing chemicals within the subject fume hood. Following the event, testing of the fume hood was conducted to assess the performance of the fume hood. Based on observations from the testing, it was deemed appropriate to conduct performance evaluations of other fume hoods within the laboratory.
Date: March 26, 2007
Creator: Ruelas, B. H.
Object Type: Report
System: The UNT Digital Library
300 Area Building Retention Evaluation Mitigation Plan (open access)

300 Area Building Retention Evaluation Mitigation Plan

Evaluate the long-term retention of several facilities associated with the PNNL Capability Replacement Laboratory and other Hanfor mission needs. WCH prepared a mitigation plan for three scenarios with different release dates for specific buildings. The evaluations present a proposed plan for providing utility services to retained facilities in support of a long-term (+20 year) lifespan in addition to temporary services to buildings with specified delayed release dates.
Date: July 3, 2007
Creator: McBride, D. J.
Object Type: Report
System: The UNT Digital Library
300 Area D4 Project 4th Quarter Fiscal Year 2006 Building Completion Report (open access)

300 Area D4 Project 4th Quarter Fiscal Year 2006 Building Completion Report

This report documents the deactivation, decontamination, decommissioning, and demolition (D4) of nine buildings in the 300 Area of the Hanford Site. The D4 of these facilities included characterization, engineering, removal of hazardous and radiologically contaminated materials, equipment removal, utility disconnection, deactivation, decontamination, demolition of the structure, and stabilization or removal of the remaining slab and foundation, as appropriate.
Date: January 30, 2007
Creator: Smith, D. S.
Object Type: Report
System: The UNT Digital Library

300 Area IFC Site and Data Management

This report presents site and data management of 300 Area IFC.
Date: April 19, 2007
Creator: Freshley, Mark
Object Type: Presentation
System: The UNT Digital Library