Resource Type

Month

Language

EFFECT OF COMPRESSION ON CONDUCTIVITY AND MORPHOLOGY OF PFSA MEMBRANES (open access)

EFFECT OF COMPRESSION ON CONDUCTIVITY AND MORPHOLOGY OF PFSA MEMBRANES

Polymer-Electrolyte-Fuel-Cells (PEFCs) are promising candidates for powering vehicles and portable devices using renewable-energy sources. The core of a PEFC is the solid electrolyte membrane that conducts protons from anode to cathode, where water is generated. The conductivity of the membrane, however, depends on the water content of the membrane, which is strongly related to the cell operating conditions. The membrane and other cell components are typically compressed to minimize various contact resistances. Moreover, the swelling of a somewhat constrained membrane in the cell due to the humidity changes generates additional compressive stresses in the membrane. These external stresses are balanced by the internal swelling pressure of the membrane and change the swelling equilibrium. It was shown using a fuel-cell setup that compression could reduce the water content of the membrane or alter the cell resistance. Nevertheless, the effect of compression on the membrane’s transport properties is yet to be understood, as well as its implications in the structure-functions relationships of the membrane. We previously studied, both experimentally and theoretically, how compression affects the water content of the membrane.6 However, more information is required the gain a fundamental understanding of the compression effects. In this talk, we present the results of …
Date: July 20, 2011
Creator: Kusoglu, Ahmet; Weber, Adam; Jiang, Ruichin & Gittleman, Craig
System: The UNT Digital Library
A simple method for enzymatic synthesis of unlabeled and radiolabeled Hydroxycinnamate-CoA (open access)

A simple method for enzymatic synthesis of unlabeled and radiolabeled Hydroxycinnamate-CoA

Hydroxycinnamate coenzyme A (CoA) thioesters are substrates for biosynthesis of lignin and hydroxycinna- mate esters of polysaccharides and other polymers. Hence, a supply of these substrates is essential for investigation of cell wall biosynthesis. In this study, three recombinant enzymes, caffeic acid 3-O-methyltransferase, 4-coumarate- CoA ligase 1, and 4-coumarate-CoA ligase 5, were cloned from wheat, tobacco, and Arabidopsis, respectively, and were used to synthesize {sup 14}C-feruloyl-CoA, caffeoyl-CoA, p-coumaroyl-CoA, feruloyl-CoA, and sinapoyl-CoA. The corresponding hydroxycinnamoyl-CoA thioesters were high-performance liquid chromatography purified, the only extraction/purification step necessary, with total yields between 88-95%. Radiolabeled {sup 14}C-feruloyl-CoA was generated from caffeic acid and S-adenosyl-{sup 14}C-methionine under the combined action of caffeic acid 3-O-methyltransferase and 4-coumarate-CoA ligase 1. About 70% of {sup 14}C-methyl groups from S-adenosyl methionine were incorporated into the final product. The methods presented are simple, fast, and efficient for the preparation of the hydroxycinnamate thioesters.
Date: July 20, 2011
Creator: Rautergarten, Carsten; Baidoo, Edward; Keasling, Jay & Vibe Scheller, Henrik
System: The UNT Digital Library
Ionic liquid pretreatment (open access)

Ionic liquid pretreatment

None
Date: July 20, 2011
Creator: Simmons, Blake; Singh, Seema; Holmes, Bradley & Blanch, Harvey
System: The UNT Digital Library
Analysis of Conductor Impedances Accounting for Skin Effect and Nonlinear Permeability (open access)

Analysis of Conductor Impedances Accounting for Skin Effect and Nonlinear Permeability

It is often necessary to protect sensitive electrical equipment from pulsed electric and magnetic fields. To accomplish this electromagnetic shielding structures similar to Faraday Cages are often implemented. If the equipment is inside a facility that has been reinforced with rebar, the rebar can be used as part of a lighting protection system. Unfortunately, such shields are not perfect and allow electromagnetic fields to be created inside due to discontinuities in the structure, penetrations, and finite conductivity of the shield. In order to perform an analysis of such a structure it is important to first determine the effect of the finite impedance of the conductors used in the shield. In this paper we will discuss the impedances of different cylindrical conductors in the time domain. For a time varying pulse the currents created in the conductor will have different spectral components, which will affect the current density due to skin effects. Many construction materials use iron and different types of steels that have a nonlinear permeability. The nonlinear material can have an effect on the impedance of the conductor depending on the B-H curve. Although closed form solutions exist for the impedances of cylindrical conductors made of linear materials, computational …
Date: July 20, 2011
Creator: Perkins, M. P.; Ong, M. M.; Brown, C. G. & Speer, R. D.
System: The UNT Digital Library
Autonomous Monitoring of Control Hardware to Predict Off-Normal Conditions Using NIF Automatic Alignment Systems (open access)

Autonomous Monitoring of Control Hardware to Predict Off-Normal Conditions Using NIF Automatic Alignment Systems

The National Ignition Facility (NIF) is a high power laser system capable of supporting high-energy-density experimentation as a user facility for the next 30 years. In order to maximize the facility availability, preventive maintenance enhancements are being introduced into the system. An example of such an enhancement is a camera-based health monitoring system, integrated into the automated alignment system, which provides an opportunity to monitor trends in measurements such as average beam intensity, size of the beam, and pixel saturation. The monitoring system will generate alerts based on observed trends in measurements to allow scheduled pro-active maintenance before routine off-normal detection stops system operations requiring unscheduled intervention.
Date: July 20, 2011
Creator: Awwal, A.; Wilhelmsen, K.; Leach, R.; Kamm, V. M.; Burkhart, S.; Lowe-Webb, R. et al.
System: The UNT Digital Library
THE EFFECTS OF HALIDE MODIFIERS ON THE SORPTION KINETICS OF THE LI-MG-N-H SYSTEM (open access)

THE EFFECTS OF HALIDE MODIFIERS ON THE SORPTION KINETICS OF THE LI-MG-N-H SYSTEM

The effects of different transition metal halides (TiCl{sub 3}, VCl{sub 3}, ScCl{sub 3} and NiCl{sub 2}) on the sorption properties of the 1:1 molar ratio of LiNH{sub 2} to MgH{sub 2} are investigated. The modified mixtures were found to contain LiNH{sub 2}, MgH{sub 2} and LiCl. TGA results showed that the hydrogen desorption temperature was reduced with the modifier addition in this order: TiCl{sub 3} > ScCl{sub 3} > VCl{sub 3} > NiCL{sub 2}. Ammonia release was not significantly reduced resulting in a weight loss greater than the theoretical hydrogen storage capacity of the material. The isothermal sorption kinetics of the modified systems showed little improvement after the first dehydrogenation cycle over the unmodified system but showed drastic improvement in rehydrogenation cycles. X-ray diffraction and Raman spectroscopy identified the cycled material to be composed of LiH, MgH{sub 2}, Mg(NH{sub 2}){sub 2} and Mg{sub 3}N{sub 2}.
Date: July 20, 2011
Creator: Anton, D.; Gray, J.; Price, C. & Lascola, R.
System: The UNT Digital Library
Interfacing Chapel with traditional HPC programming languages (open access)

Interfacing Chapel with traditional HPC programming languages

None
Date: July 20, 2011
Creator: Prantl, A.; Epperly, T.; Imam, S. & Sarkar, V.
System: The UNT Digital Library
Transport and Non-Invasive Position Detection of Electron Beams from Laser-Plasma Accelerators (open access)

Transport and Non-Invasive Position Detection of Electron Beams from Laser-Plasma Accelerators

The controlled imaging and transport of ultra-relativistic electrons from laser-plasma accelerators is of crucial importance to further use of these beams, e.g. in high peak-brightness light sources. We present our plans to realize beam transport with miniature permanent quadrupole magnets from the electron source through our THUNDER undulator. Simulation results demonstrate the importance of beam imaging by investigating the generated XUV-photon flux. In addition, first experimental findings of utilizing cavity-based monitors for non-invasive beam-position measurements in a noisy electromagnetic laser-plasma environment are discussed.
Date: July 20, 2011
Creator: Osterhoff, Jens; Sokollik, Thomas; Nakamura, Kei; Bakeman, Michael; Weingartner, R; Gonsalves, Anthony et al.
System: The UNT Digital Library
Ten-fold spectral resolution boosting using TEDI at the Mt. Palomar NIR Triplespec spectrograph (open access)

Ten-fold spectral resolution boosting using TEDI at the Mt. Palomar NIR Triplespec spectrograph

None
Date: July 20, 2011
Creator: Erskine, D. J.; Edelstein, J.; Muirhead, P.; Muterspaugh, M.; Covey, K.; Mondo, D. et al.
System: The UNT Digital Library