Measurement of Large, High-Frequency, Short-Pulse Currents Using a Radial Shunt (open access)

Measurement of Large, High-Frequency, Short-Pulse Currents Using a Radial Shunt

Abstract: "The measurement of large, high-frequency, short-pulse currents--ordinarily complicated by inductance, stray magnetic fields, and magnetic forces that tend to disassemble the measuring device--is simplified and made with an average error of 2-1/2% by the use of a specially developed noninductive radial shunt in conjuntion with an oscilloscope. The skin-effect correction is derived theoretically and the accuracy of the method is demonstrated."
Date: May 22, 1956
Creator: McFarlane, H. Bruce
System: The UNT Digital Library
Corrosion Data for Type 347 Stainless Steel Pipe Waste Metal Recovery Process (open access)

Corrosion Data for Type 347 Stainless Steel Pipe Waste Metal Recovery Process

Introduction: "A limited test progress for the evaluation of type 347 stainless steel pipe which failed the Huey (?) test has been complicated. The tests reported herein were similar in scope to those reported in document number EW-20765, Corrosion Tests on Stainless Steel Plate, Waste Metal Recovery Process. Material tested was obtained on order number EWC-8553, National Tube Company Heat #3X9741. Lots 9789 and 9790."
Date: May 22, 1951
Creator: Sanborn, Kenneth L.
System: The UNT Digital Library
Fundamental Equations Describing Neutron Behavior in a Cavity (open access)

Fundamental Equations Describing Neutron Behavior in a Cavity

This report provides fundamental equations and maps to calculate neutron behavior in a spherical cavity.
Date: May 22, 1951
Creator: Willmer, D. B. & Imhoff, D. H.
System: The UNT Digital Library
Pressure Drop Along a Fuel Cycle Fuel Assembly - Various Orifice Configurations (open access)

Pressure Drop Along a Fuel Cycle Fuel Assembly - Various Orifice Configurations

The objective is to establish, from test results, the relationship between pressure loss and orifice configuration, mass rate, and steam quality, for a Fuel Cycle fuel assembly.
Date: May 22, 1961
Creator: Janssen, E. (Engineer) & Kervinen, J. A.
System: The UNT Digital Library
Hazardous Materials - Redox Plant (open access)

Hazardous Materials - Redox Plant

The Redox process uses or produces only a very few materials that are hazardous for reasons other than radioactivity. The conditions under which these materials become hazardous were carefully taken into consideration in the development of the process and design of the equipment. A considerable about of information on the hazardous properties of the process materials was obtained so that the pertinent material could be incorporated into the process specifications. Providing the equipment is operating properly and the process is being carried out within specification limits, no hazardous conditions can be created by the process. The purpose of this report is to assemble in a single, readily available document all of the information on the normal concentration limits and safe handling procedures needed to adequately control the use and storage of these materials. This report should be helpful in preparing safety bulletins and provide guidance in case of unusual incidents, malfunctioning of equipment, or contemplated changes in either the process or equipment. It is important to remember that a maximum allowable concentration (MAC) is only a limit on the concentration of a toxic material which cannot be exceeded in the air to which workers are constantly exposed to every working …
Date: May 22, 1956
Creator: Underwood, J. W.
System: The UNT Digital Library
MTA Target Equations (open access)

MTA Target Equations

In solving the two-group, two medium equations for neutron diffusion in a finite one-dimensional multiplying system, the equations in each medium can be solved, and the boundary conditions used to determine the coefficients. This direct attack involves eight simultaneous linear equations. The opportunities for error are numerous, and, frequently, a great deal of accuracy is lost by subtractions; hence, it is felt that an alternative method of solution, in which numerical errors would be less likely to occur, would be desirable.
Date: May 22, 1952
Creator: Kramer, H. P. & Adelman, F.
System: The UNT Digital Library
Decontamination of Portable Instruments (open access)

Decontamination of Portable Instruments

The decontamination of portable instruments by the Calibration Unit has presented a problem for some time. Most of the contamination is in the 100 to 500 c/m or 500 to 2000 d/m range. Higher levels of contamination can usually be reduced to these levels, but further cleaning proves quite difficult
Date: May 22, 1953
Creator: Unruh, C. M.
System: The UNT Digital Library
The Effect of Solution and Vessel Thermal Expansion on Volume Measurements in the Chemical Processing Department (open access)

The Effect of Solution and Vessel Thermal Expansion on Volume Measurements in the Chemical Processing Department

The major portion of transfers and inventory in the Chemical Processing Department are dependent on volume measurement. Good volume measurements are therefore essential to good SS material control. Considerable attention has been given to the volume problem especially on primary transfer points. Document HW-57888 discusses the biasing effect pf temperature on manometer oil. HW- 57866 given the procedure for vessel calibration. Other undocumented correspondence has discussed recent calibrations and certain aspects of temperature considerations in the volume determinations. However, there is a need to document for future reference the consideration given temperature and provide at the same time information which covers the temperature angle on all volume methods used in the Chemical Processing Department.
Date: May 22, 1959
Creator: Johnson, W. R.
System: The UNT Digital Library
Oralloy Hydride Critical Assemblies (open access)

Oralloy Hydride Critical Assemblies

Part I of this report covers critical-mass determinations for pseudospheres of oralloy hydride composition (approximating UH3) in 8"-thick Tu and Ni tampers and in the Tu tamper with Ni liner. The critical mass of a hydride cube in the thick Tu also is given. Data on weight and dimensional changes of hydride pieces during the period of use are included. In Part II are presented the results of Rossi time-scale measurements on the hydride assemblies. Values of alpha at delayed critical and its variation with mass in the neighborhood of delayed critical are given. Measurements on the activation of various detectors within the hydride assemblies are described in Part III. Results as a function of radial position are given for Au, for Au shielded by Au and by Cd, for S and for fission catchers with U235 and U238. Reactivity changes resulting from the introduction of foreign materials into the hydride assemblies are discussed in Part IV. Apparent regularities with respect to Z and qualitative interpretations of variations with radius are pointed out. From data for various radial positions, changes in critical mass corresponding to small changes in composition and density are computed.
Date: May 22, 1950
Creator: Paxton, Hugh Campbell; Orndoff, John D. & Linenberger, G. A. (Gustave Aaron)
System: The UNT Digital Library
Report of Fire in Laboratory Hood, Wing I, Building 4500 (open access)

Report of Fire in Laboratory Hood, Wing I, Building 4500

The fire involved approximately 30 liters of isopropyl alcohol as a result of the ignition of about 16-18 liters of isopropyl alcohol and a slurry of thoria and ammonium nitrate in a 20-liter glass carboy. This material was undergoing a volume reduction by boiling in a floor-type metal hood with Plexiglas sides and 3 sliding door on the front of ordinary glass. The alcohol vapor was vents directly into the hood (Fig1.)
Date: May 22, 1959
Creator: Lain, J. E. & Hungerford, T. W.
System: The UNT Digital Library
Summary of Corrosion Data for HRT Mockup Operational Period Ending November 5, 1956 (open access)

Summary of Corrosion Data for HRT Mockup Operational Period Ending November 5, 1956

The operation of the HRT mockup was on 0.042m UO2SO4, 0.024m H2SO4, and 0.005m CuSO4 at 280 C and 1400 psi pressure. with the O2 content at near 500 ppm. The pump showed bearing wear and high corrosion. The letdown heat exchanger was removed from the mockup and sectioned. The metallographic examination revealed corrosion. Results of corrosion runs on Ti, zircaloy-2, and stainless steel are given.
Date: May 22, 1957
Creator: Wacker, R. E. & Griess, J. C.
System: The UNT Digital Library
In-Reactor Autoclave Corrosion Studies : LITR I.  Outline of Methods and Procedures (open access)

In-Reactor Autoclave Corrosion Studies : LITR I. Outline of Methods and Procedures

During the development of in-reactor corrosion experiments three types of bomb designs have been developed for following quantitatively the consumption of oxygen in a bomb which is fabricated from the particular metal under test. The bombs are designed so as to be rocked continuously during their in-reactor exposure, consequently agitating the uranium salt solution contained in the bomb and permitting gentle movement of the solution past metal specimens and other corroding surfaces. The oxygen pressure is produced within the bomb at the beginning of the run either by the withdrawal of gas from an oxygen tank or by the decomposition of hydrogen peroxide added just prior to closure. Temperature measurements are obtained by mans of thermocouples placed in a well within the bomb body or, in the latest design, there will also be thermocouples staked at several points on the outer wall of the bomb. The assembly is inserted in an experimental access hole in the reactor, brought up to a predetermined operating temperature by means of an electric furnace in close contact with the bomb, and allowed to remain for the desired amount of exposure to reactor radiation. Periodic measurements of temperature and pressure are made and the bomb …
Date: May 22, 1957
Creator: Warren, K. S. & Davis, R. J.
System: The UNT Digital Library