Resource Type

Month

Language

50 MW X-BAND RF SYSTEM FOR A PHOTOINJECTOR TEST STATION AT LLNL (open access)

50 MW X-BAND RF SYSTEM FOR A PHOTOINJECTOR TEST STATION AT LLNL

In support of X-band photoinjector development efforts at LLNL, a 50 MW test station is being constructed to investigate structure and photocathode optimization for future upgrades. A SLAC XL-4 klystron capable of generating 50 MW, 1.5 microsecond pulses will be the high power RF source for the system. Timing of the laser pulse on the photocathode with the applied RF field places very stringent requirements on phase jitter and drift. To achieve these requirements, the klystron will be powered by a state of the art, solid-state, high voltage modulator. The 50 MW will be divided between the photoinjector and a traveling wave accelerator section. A high power phase shifter is located between the photoinjector and accelerator section to adjust the phasing of the electron bunches with respect to the accelerating field. A variable attenuator is included on the input of the photoinjector. The distribution system including the various x-band components is being designed and constructed. In this paper, we will present the design, layout, and status of the RF system.
Date: March 11, 2011
Creator: Marsh, R A; Anderson, S G; Barty, C J; Beer, G K; Cross, R R; Ebbers, C A et al.
System: The UNT Digital Library
22X mask cleaning effects on EUV lithography process and lifetime (open access)

22X mask cleaning effects on EUV lithography process and lifetime

For this paper, we evaluated the impact of repetitive cleans on a photomask that was fabricated and patterned for extreme ultraviolet lithography exposure. The lithographic performance of the cleaned mask, in terms of process window and line edge roughness, was monitored with the SEMATECH Berkeley micro-exposure tool (MET). Each process measurement of the cleaned mask was compared to a reference mask with the same mask architecture. Both masks were imaged on the same day in order to eliminate any process-related measurement uncertainties. The cleaned mask was periodically monitored with atomic force microscopy (AFM) measurements and pattern widths were monitored using scanning electron microscopy (SEM). In addition, reflectivity changes were also tracked with the aid of witness plate measurements. At the conclusion of this study, the mask under evaluation was cleaned 22 times; with none of the evaluation techniques showing any significant degradation in performance.
Date: March 11, 2011
Creator: George, Simi A.; Chen, Robert J.; Baclea-an, Lorie Mae & Naulleau, Patrick P.
System: The UNT Digital Library
Absorber height effects on SWA restrictions and 'Shadow' LER (open access)

Absorber height effects on SWA restrictions and 'Shadow' LER

None
Date: March 11, 2011
Creator: McClinton, Brittany M.; Naulleau, Patrick P. & Wallow, Thomas
System: The UNT Digital Library
Mask roughness induced LER control and mitigation: aberrations sensitivity study and alternate illumination scheme (open access)

Mask roughness induced LER control and mitigation: aberrations sensitivity study and alternate illumination scheme

Here we conduct a mask-roughness-induced line-edge-roughness (LER) aberrations sensitivity study both as a random distribution amongst the first 16 Fringe Zernikes (for overall aberration levels of 0.25, 0.50, and 0.75nm rms) as well as an individual aberrations sensitivity matrix over the first 37 Fringe Zernikes. Full 2D aerial image modeling for an imaging system with NA = 0.32 was done for both the 22-nm and 16-nm half-pitch nodes on a rough mask with a replicated surface roughness (RSR) of 100 pm and a correlation length of 32 nm at the nominal extreme-ultraviolet lithography (EUVL) wavelength of 13.5nm. As the ideal RSR value for commercialization of EUVL is 50 pm and under, and furthermore as has been shown elsewhere, a correlation length of 32 nm of roughness on the mask sits on the peak LER value for an NA = 0.32 imaging optic, these mask roughness values and consequently the aberration sensitivity study presented here, represent a worst-case scenario. The illumination conditions were chosen based on the possible candidates for the 22-nm and 16-nm half-pitch nodes, respectively. In the 22-nm case, a disk illumination setting of {sigma} = 0.50 was used, and for the 16-nm case, crosspole illumination with {sigma} = …
Date: March 11, 2011
Creator: McClinton, Brittany M. & Naulleau, Patrick P.
System: The UNT Digital Library
Out of band radiation effects on resist patterning (open access)

Out of band radiation effects on resist patterning

Our previous work estimated the expected out-of-band (OOB) flare contribution at the wafer level assuming that there is a given amount of OOB at the collector focus. We found that the OOB effects are wavelength, resist, and pattern dependent. In this paper, results from rigorous patterning evaluation of multiple OOB-exposed resists using the SEMATECH Berkeley 0.3-NA MET are presented. A controlled amount of OOB is applied to the resist films before patterning is completed with the MET. LER and process performance above the resolution limit and at the resolution limits are evaluated and presented. The results typically show a negative impact on LER and process performance after the OOB exposures except in the case of single resist formulation, where resolution and performance improvement was observed.
Date: March 11, 2011
Creator: George, Simi A . & Naulleau, Patrick P.
System: The UNT Digital Library
Replicated mask surface roughness effects on EUV lithographic pattering and line edge roughness (open access)

Replicated mask surface roughness effects on EUV lithographic pattering and line edge roughness

To quantify the roughness contributions to speckle, a programmed roughness substrate was fabricated with a number of areas having different roughness magnitudes. The substrate was then multilayer coated. Atomic force microscopy (AFM) surface maps were collected before and after multilayer deposition. At-wavelength reflectance and total integrated scattering measurements were also completed. Angle resolved scattering based power spectral densities are directly compared to the AFM based power spectra. We show that AFM overpredicts the roughness in the picometer measurements range. The mask was then imaged at-wavelength for the direct characterization of the aerial image speckle using the SEMATECH Berkeley Actinic Inspection Tool (AIT). Modeling was used to test the effectiveness of the different metrologies in predicting the measured aerial-image speckle. AIT measured contrast values are 25% or more than the calculated image contrast values obtained using the measured rms roughness input. The extent to which the various metrologies can be utilized for specifying tolerable roughness limits on EUV masks is still to be determined. Further modeling and measurements are being planned.
Date: March 11, 2011
Creator: George, Simi A.; Naulleau, Patrick P.; Gullikson, Eric M.; Mochi, Iacopo; Salmassi, Farhad; Goldberg, Kenneth A. et al.
System: The UNT Digital Library