Serial/Series Title

Language

Physical Properties of the System Uranyl Nitrate - Aluminum Nitrate - Nitric Acid - Water - Hexone: Part 6. Distribution Coefficients of Plutonium(IV) Nitrate (open access)

Physical Properties of the System Uranyl Nitrate - Aluminum Nitrate - Nitric Acid - Water - Hexone: Part 6. Distribution Coefficients of Plutonium(IV) Nitrate

Report discussing the properties of plutonium and plutonium's distribution between hexone and aqueous phases, which relates to the function of Redox plants
Date: December 1, 1950
Creator: Groot, C.; Rehn, I. M. & Slansky, C. M.
System: The UNT Digital Library
The Ratio of Plutonium 239 to Uranium 235 Fission Cross Sections from 0.020 to 1.0 Electron Volts (open access)

The Ratio of Plutonium 239 to Uranium 235 Fission Cross Sections from 0.020 to 1.0 Electron Volts

Foils of plutonium 239 and uranium 235 have been mounted back to back in a dual ionization fission chamber in the diffracted beam of the Hanford neutron crystal spectrometer. A quantity proportional to the ration of fission cross sections of Pu239 to U235 has been measured as a function of neutron energy from 0.020 to 1.0 electron volts. The results of this investigation are presented graphically in the text.
Date: December 1, 1953
Creator: Leonard, B. R., Jr.; Hauser, S. M. & Seppi, E. J.
System: The UNT Digital Library
Comments on Equipment for a PRTR Water Quality Control Laboratory (open access)

Comments on Equipment for a PRTR Water Quality Control Laboratory

This document describes required laboratory space and lists major equipment items necessary for a routine water quality laboratory in the P. R. T. R. Building. During discussions with R. D. Widrig and V. L. Rooney about the analytical sample program for the Plutonium Recycle Test Reactor, the author was asked to summarize equipment and space needs for a water control laboratory to provide routine analytical coverage on some of the water systems. Based upon 1706-KE-KER experience, some operating personnel may be used to provide analytical coverage on those routine analyses that are needed on around-the-clock basis with a savings of both time and money.
Date: December 1, 1959
Creator: Anderson, H. J. & Peray, R. E.
System: The UNT Digital Library
Autoclave Corrosion Behavior of U-Low Carbon and U-Low Zirconium Alloy Fuels (open access)

Autoclave Corrosion Behavior of U-Low Carbon and U-Low Zirconium Alloy Fuels

A preliminary evaluation of the autoclave corrosion behavior of a series of U-low C alloys and a series of U-low Zr alloys prepared by Fuels Fabrication Development Operation has been made. The corrosion testing was conducted by Coatings and Corrosion Operation by the experimental methods and procedure outlined in HW-61378.
Date: December 1, 1959
Creator: Goffard, J. W.
System: The UNT Digital Library