Use of AERIN code for determining internal doses of transuranic isotopes (open access)

Use of AERIN code for determining internal doses of transuranic isotopes

The AERIN computer code is a mathematical expression of the ICRP Lung Model. The code was developed at the Lawrence Livermore National Laboratory to compute the body organ burdens and absorbed radiation doses resulting from the inhalation of transuranic isotopes and to predict the amount of activity excreted in the urine and feces as a function of time. Over forty cases of internal exposure have been studied using the AERIN code. The code, as modified, has proven to be extremely versatile. The case studies presented demonstrate the excellent correlation that can be obtained between code predictions and observed bioassay data. In one case study a discrepancy was observed between an in vivo count of the whole body and the application of the code using urine and fecal data as input. The discrepancy was resolved by in vivo skull counts that showed the code had predicted the correct skeletal burden.
Date: June 13, 1980
Creator: King, W.C.
System: The UNT Digital Library