Correlation of forced-convection heat-transfer data for air flowing in smooth platinum tube with long-approach entrance at high surface and inlet-air temperatures (open access)

Correlation of forced-convection heat-transfer data for air flowing in smooth platinum tube with long-approach entrance at high surface and inlet-air temperatures

A heat-transfer investigation was conducted with air in an electrically heated platinum tube with long-approach entrance, inside diameter of 0.525 inch, and effective heat-transfer length of 24 inches over ranges of Reynolds number up to 320,000, average inside-tube-wall temperature up to 3053 degrees R, and inlet-air temperature up to 1165 degrees R. Correlation of data by the conventional Nusselt relation resulted in separation of data with tube-wall temperature. Good correlation was obtained, however, by use of a modified Reynolds number.
Date: November 2, 1950
Creator: Desmon, Leland G. & Sams, Eldon W.
System: The UNT Digital Library